Laserfiche WebLink
STRUCTURAL NOTES: <br />1. DESIGN LOADS, <br />DEAD LOAD, THE FOLLOWING UNIT LOADS SHALL <br />BE USED IN CALCULATING DEAD LOADS, <br />STRUCTURAL STEEL - 490 pcf <br />REINFORCED CONCRETE - 150 pcf <br />ALUMINUM - 165 pcf <br />2. DESIGN METHODS, <br />REINFORCED CONCRETE, LOAD AND RESISTANCE FACTOR DESIGN <br />3. THERMAL FORCES, <br />A. SEASONAL VARIATION.' <br />TEMPERATURE RANGE FOR DESIGN OF STRUCTURE, <br />TEMPERATURE RISE - 30' F <br />TEMPERATURE FALL = 40' F <br />B. MEAN TEMPERATURE = 70' F <br />C. THERMAL COEFFICIENT = 0.000006 PER DEGREE F <br />4. CREEP AND SHRINKAGE, <br />STRAINS ARE AS PER AASHTO. <br />ULTIMATE CONCRETE SHRINKAGE COEFFICIENT = 0,0004 IN/IN <br />5. STAY -IN-PLACE FORMS ARE NOT PERMITTED DUE TO EXTREMELY <br />AGGRESSIVE ENVIRONMENT. <br />6. ALLOWABLE STRESSES/LOADS, <br />REINFORCED CONCRETE, AS PER AASHTO. <br />PRESTRESSED CONCRETE, <br />CONCRETE STRENGTH AT TRANSFER, f'ci= 0.8f'c = 6.8 ksi <br />CONCRETE STRENGTH AT 28 DAYS, ('c = 8.5 ksi <br />A. TEMPORARY STRESSES BEFORE LOSSES, <br />COMPRESSION = 0.60f'ci = 4.08 ksi <br />TENSION (WITHOUT BONDED REINFORCEMENT) = 0.200 ksi <br />TENSION (WITH BONDED REINFORCEMENT) = 0.625 ksi <br />B. SERVICE LIMIT STATES AFTER LOSSES, FULLY PRESTRESSED, <br />DUE TO EFFECTIVE PRESTRESS AND <br />PERMANENT LOADS - <br />DUE TO LL AND %THE SUM OF EFFECTIVE <br />PRESTRESSING AND PERMANENT LOADS = <br />DUE TO PRESTRESS, PERMANENT AND <br />TRANSIENT/LIVE LOAD = <br />TENSION (UNLESS OTHERWISE NOTED) <br />0.45Pc (3.82 ksi) <br />0.40I'c (3.40 ksi) <br />0.6f'c (5.10 ksi) <br />0.280 ksi <br />7. MATERIALS, <br />A. EPDXY MORTAR, ALL EPDXY MORTAR SHALL CONFORM WITH <br />FOOT STANDARD SPECIFICATIONS SECTION 346. <br />B. REINFORCING STEEL, ALL REINFORCING STEEL SHALL BE <br />UNCOATED ASTM A615 GRADE 60. <br />CONCRETE COVERS SHALL BE AS FOLLOWS (UNLESS OTHERWISE NOTED), <br />SUPERSTRUCTURE, <br />PRE- STRESSED BEAMS, 2" <br />TOP DECK SURFACE, Vs" <br />ALL OTHER SURFACES, 2" <br />SUBS TRUCTURE+ <br />EXTERNAL FORMED SURFACES, PILE CAPS, <br />SHEAR BLOCKS AND PILE EXTENSIONS <br />NOT IN CONTACT WITH WATER, 4" <br />CONCRETE COVER SHOWN IN THE PLANS DO NOT INCLUDE <br />REINFORCEMENT PLACEMENT AND FABRICATION TOLERANCES <br />UNLESS SHOWN AS "MINIMUM COVER". SEE SPECIFICATIONS <br />FOR ALLOWABLE REINFORCEMENT PLACEMENT TOLERANCES. <br />C. PRESTRESSING STEEL, ALL PRE -STRESSING STEEL SHALL BE <br />STRAND ASTM A416 GRADE 270, LOW RELAXATION. <br />PRESTRESSING PARAMETERS (STRAND), <br />APPARENT MODULUS, 28,000 ksi <br />MAXIMUM JACKING STRESS, 216 ksi (80X ULTIMATE) <br />MAXIMUM ANCHORING $TRESS AT ANCHOR, <br />202 ksi (757 ULTIMATE) FOR PRETENSIONING <br />STRAND DIAMETER, 0.60" <br />CONTRACTOR SHALL NOT RELEASE PRESTRESSING UNTIL AD£OUATE <br />STRENGTH HAS BEEN ACHIEVED AS SHOWN BY THE RESULTS OF THE <br />TEST CYLINDERS AND APPROVED BY THE ENGINEER. <br />D. CONCRETE, (28 DAY CYLINDER STRENGTH AS NOTED) <br />PRE- STRESSED CONCRETE BEAMS (FLORIDA INVERTED -T) <br />CLASS VI Pc = 8,500 psi <br />CAST -IN-PLACE SUPERSTRUCTURE (BRIDGE DECK, DIAPHRAGMS, <br />CURB) <br />CLASS IV Pc = 5500 psi <br />CAST -IN-PLACE SUBSTRUCTURE (PILE EXTENSION <br />AND PILE CAPS) <br />CLASS IV f'c - 5500 psi <br />E. MAXIMUM AGGREGATE SIZE FOR PRECAST MEMBERS <br />F. PROVIDE V4" CHAMFERS ON ALL EXPOSED EDGES (UNLESS <br />OTHERWISE NOTED). <br />L.""4-A.17---.CoP'aF'S' S' <br />4 <br />8. ALLOWABLE STRESSES ARE IN ACCORDANCE WITH THE <br />REFERENCED DESIGN SPECIFICATIONS FOR ALL MATERIAL <br />SHOWN ON THE PLANS. <br />9. EXISTING ELEMENTS TO REPAIR, <br />EXERCISE SPECIAL CARE NOT TO DAMAGE ANY ELEMENTS OF <br />THE STRUCTURE THAT ARE TO REMAIN, INCLUDING EXISTING <br />REINFORCING. REPAIR OR REPLACE, TO THE SATISFACTION OF <br />THE ENGINEER, ANY ELEMENTS THAT ARE TO REMAIN, WHICH <br />ARE DAMAGED DURING CONSTRUCTION AT NO ADDITIONAL <br />COST TO THE COUNTY. <br />10. DIMENSIONS, <br />VERIFY ALL DIMENSION AND ELEVATIONS WITHIN THESE PLANS <br />PRIOR TO CONSTRUCTION AND REPAIRS. IF ANY DISCREPANCIES ARE <br />FOUND IMMEDIATELY NOTIFY THE ENGINEER. THE CONTRACTOR <br />SHALL BE SOLELY RESPONSIBLE FOR FABRICA TfDN AND F1T OF HIS <br />WORK TO PROPERLY INTERFACE WITH THE EXISTING STRUCTURE. <br />ANCn REV ISI O N S <br />IVIES <br />DATES <br />DAR <br />BY <br />DESCRIPTION <br />DATE <br />BY <br />DESEIPTION <br />SAM BY <br />A)(8 <br />8/06 <br />OECTEO BY <br />CG <br />8/06 <br />DESIGNED BY <br />GG <br />8/06 <br />CIRCE° NY <br />TJN <br />.8/06 <br />APPROVED BB <br />T.J Wes, P.E. <br />ENGINEER OF RECORD. <br />HARDESTT & HANOVOR. LIP <br />1000 BAWGRA88 CORPORATE WIWI <br />SUITE 544 <br />auntie.. PL 33123 <br />Cesar A Granada*, P.E. 064221 <br />Ce76ficofe of Aa/Aorira6on 0171 <br />INDIAN RIVER COUNTY PUBLIC WORKS DEPARTMENT <br />ROAD N0. <br />CONTI <br />FINANCIAL PROJECT ID <br />STRUCTURAL NOTES <br />CR 510 <br />INDIAN RIVER <br />PAa,aPNAr CR 510 OVER INTRACOASTAL WATERWAY <br />WABASSO FISHING PIER REPAIRS <br />00A Et 1711/0 <br />'OILEI <br />TMST N0. <br />81-2 <br />