Laserfiche WebLink
Page 3 of 8 <br />W-8 - Temporary Sampling Point (Bacteriological). Call -out notes have been revised. Copper tubing has <br />been revised to read: "P.E. 1" Ball Valve or Curb Stop". Note "Water Main or Service" has been added. <br />Note 1 has been revised. Added Note 5. <br />W-9 - Full Bore Flushing. New Title Block and Font was the only revision. <br />W-10 - Double -Detector Check Valve Assembly. All Notes have been moved to a new drawing W-10 A. <br />W-10 A - Double -Detector Check Valve Assembly Notes. New drawing. Notes are from W-10. <br />W-11 - Reduced Pressure Backflow Preventer (RPZ). New Title Block and Font was the only revision. <br />W-12 - Master Meter Combination Assembly (3" or Larger). All Notes have been moved to a new drawing <br />W-12 A. <br />W-12 A - Master Meter Combination Assembly. New drawing. Notes are from W-12. Note 2 has been <br />revised to read: "By-pass pipe diameter shall be determined per Engineer of Record". <br />W-13 - Temporary Jumper Detail. Drawing re -oriented from portrait to landscape. Curb stops (2) and the <br />associated call -out notes have been removed. Tees (2) for sample points have been added. All Notes have <br />been moved to a new drawing W-13 A. <br />W-13 A - Temporary Jumper Detail Notes. New drawing. The Notes are from W-13 and W-14, and have <br />been edited and combined into W-13 A. Drawing W-14, Temporary Jumper Detail Notes (Continued), has <br />been eliminated. To Note 8, the words "sodium hypochlorite" has been added to further define the liquid <br />chlorine to be used. <br />S-1 - Standard Lateral (Shallow Sewer). The roadway detail has been enlarged to better illustrate the curb <br />etched with "5". A sidewalk detail has been added. Call -out notes have been revised to reference the <br />correct drawings. The Notes section has been moved to new drawing S-1 A. <br />S-1 A - Standard Lateral Notes (Shallow Sewer). New drawing. Notes are from S-1. <br />S-2 - Modified Riser Lateral (Deep Sewer). The roadway detail has been enlarged to better illustrate the <br />curb etched with "5". Call -out notes have been revised to reference the correct drawings. The Notes <br />section has been moved to new drawing S-2 A. <br />S-2 A - Modified Riser Lateral Notes (Deep Sewer). New drawing. Notes are from S-2. <br />S-3 - Sewer Lateral Riser Details. New Title Block and Font is the only revision. <br />S-4 - Standard Manhole Casting. A typo in the Plan View has been corrected (an inadvertent note copied <br />and pasted twice). <br />S-5 - Manhole Notes. Note 6 has been revised to read "2 coats black EW -1". Note 8 has been revised. <br />Deleted engineer to read "IRC Inspector in field". Note 22, Depth of Manhole Chart, has been revised to <br />read "Less Than 10' -Diameter 4". And "6'-10" has been deleted and revised to read "Greater than 10' - <br />Diameter 5' ". <br />ATTACHMENT A, Construction Standards, May 2019 <br />83 <br />