My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-147
CBCC
>
Official Documents
>
2010's
>
2019
>
2019-147
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2019 2:21:56 PM
Creation date
10/17/2019 11:43:44 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/10/2019
Control Number
2019-147
Agenda Item Number
8.X.
Entity Name
Guettler Brothers Construction,
Subject
49th Street Milling and Resurfacing, 58th Avenue to 31st Avenue
FM NO. 436850-1-54-01
Project Number
IRC-1414
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Addendum #1 <br />❑ (c) All surveys and maps or reports with elevation data shall indicate the <br />datum and a description of the benchmark(s) upon which the survey is based. <br />❑ (d) Minor elevation data may be obtained on an assumed datum provided the <br />base elevation of the datum is obviously different than the established datum. <br />(2) Horizontal Feature Accuracy: <br />❑ (a) Horizontal Control: All surveys and maps or reports expressing or <br />displaying features in a publicly published coordinate system shall indicate <br />the coordinate datum and a description of the control points upon which the <br />survey is based. <br />❑ (b) Minor coordinate data may be obtained and used on an assumed datum <br />provided the numerical basis of the datum is obviously different than a <br />publicly published datum. <br />❑ (c) The accuracy of control survey data shall be verified by redundant <br />measurements or traverse closures. All control measurements shall achieve <br />the following closures: <br />Commercial/High Risk Linear: 1 foot in 10,000 feet; <br />Suburban: Linear: 1 foot in 7,500 feet; <br />Rural: Linear: 1 foot in 5,000 feet; <br />❑ (d) When statistical procedures are used to calculate survey accuracies, the <br />maximum acceptable positional tolerance, based on the 95% confidence <br />level, should meet the same equivalent relative distance standards as set <br />forth in 61G17- 6.003(3)(p)(2.)(c) F.A.C. <br />❑ (e) Intended Display Scale: All maps or reports of surveys produced and <br />delivered with digital coordinate files must contain a statement to the effect <br />of: "This map is intended to be displayed at a scale of 1/ or smaller". <br />61G17-6.004 Specific Survey, Map, and Report Requirements <br />(1) As-Built/Record Survey: <br />❑ (a) Obtained field measurements of vertical or horizontal dimensions of <br />constructed improvements so that the constructed facility can be delineated <br />in such a way that the location of the construction may be compared with the <br />construction plans. <br />❑ (b) Clearly shows by symbols, notations, or delineations, those constructed <br />improvements located by the survey. <br />❑ (c) All maps prepared shall meet applicable minimum technical standards. <br />❑ (d) Vertical and horizontal accuracy of the measurements made shall be such <br />that it may be determined whether the improvements were constructed <br />consistent with planned locations. <br />(END OF SECTION) <br />01025-28 Technical Specifications <br />F:\Public Works\ENGINEERING DIVISION PROJECTS\1414-49th St_58th Ave to 31st Ave\1-Admin\Bids\Bid <br />Documents\Adendums\Technical Specifications uPDATED 5-25-2017.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.