Laserfiche WebLink
ROOFING REPLACEMENT PROJECT <br />NORTH COUNTY REGIONAL PARK AQUATIC CENTER <br />JUNE 7, 2019 <br />C. Downspout Strap: .050 Aluminum, ASTM B209. <br />D. Gutter: .050 Aluminum, ASTM B209. <br />E. Gutter Bracket: 1/8" x 1" Aluminum, ASTM B209. <br />F. Gutter Strap: .050 Aluminum, ASTM B209. <br />PAGE 6 <br />SECTION 076200 <br />SHEET METAL AND FLASHINGS <br />G. Gutter Throat: .050 Aluminum, ASTM B209. <br />H. Metal Cleat: 20 Gauge Stainless Steel, Type 316 <br />I. Metal Counter -flashing Type 1: 22 Gauge Stainless Steel, Type 316. <br />J. Metal Counter -flashing Type 2:.040 Aluminum, ASTM B209. <br />K. Metal Edge: .050 Aluminum, ASTM 8209. <br />L. Metal Receiver Flashing: .040 Aluminum, ASTM B209. <br />M. Metal Skirt Flashing: 22 Gauge Stainless Steel, Type 316. <br />N. Metal Trim Flashing: .050 Aluminum, ASTM B209. <br />O. One -Piece Transition Flashing: .040 Aluminum, ASTM B209. <br />P. Termination Bar: 1/8" x 1" Stainless Steel, Type 304. <br />2.7 LOW -SLOPE ROOF SHEET METAL FABRICATIONS <br />A. Roof Edge Flashing: Fabricate in minimum 96 -inch- (2400 -mm-) long, but not <br />exceeding 12 -foot- (3.6-m-) long sections. Furnish with 6 -inch- (150 -mm-) wide, joint <br />cover plates. Shop fabricate interior and exterior corners. <br />1. Fabricate from the following materials: <br />a. Stainless Steel: <br />PART 3 - EXECUTION <br />3.1 INSTALLATION OF UNDERLAYMENT <br />A. Felt Underlayment: Install felt underlayment, wrinkle free, using adhesive to minimize <br />use of mechanical fasteners under sheet metal flashing and trim. <br />1. Install in shingle fashion to shed water. <br />2. Lap joints not less than 2 inches (50 mm). <br />B. Self -Adhering, High -Temperature Sheet Underlayment: <br />