Laserfiche WebLink
INDIAN RIVER COUNTY — NORTH COUNTY REGIONAL PARK PAGE 2 <br />AQUATIC FACILITY ROOFING REPLACEMENT SECTION 075216 <br />JUNE 7, 2019 1MODIFIED BITUMINOUS MEMBRANE ROOFING <br />1.6 DESCRIPTION OF WORK <br />A. System Description: <br />1. Siplast: (Basis of Design) <br />a. Project Type: Tear -off <br />b. Deck: Existing LWIC <br />c. Slope: > 1/81 inch <br />d. Base Sheet: Nailable modified asphalt G2 base sheet with Polyolefin film <br />backing <br />e. Inner Ply: SBS modified bitumen inner ply, torch applied <br />f. Cap Ply: SBS modified bitumen cap sheet, torch applied <br />g. Flashing Membrane: Aluminum metal clad flashing <br />h. Supplemental Flashing: PMMA flashing system. <br />1.7 ACTION SUBMITTALS <br />A. Product and material safety data sheets for each product proposed for use. <br />B. Samples for Verification <br />1. Two 8 '/2 inch x 11 inch samples of the primary roofing and flashing materials, of color <br />required. <br />C. Shop Drawings <br />1. Base flashings and membrane terminations <br />2. Tapered insulation, including slopes <br />3. Crickets, saddles, and tapered edge strips, including slopes <br />4. Insulation fastening patterns for corner, perimeter, and field <br />1.8 INFORMATIONAL SUBMITTALS <br />A. Letter from the roofing manufacturer that the roofing contractor is certified to install the <br />specified products. <br />B. Latest edition of the roofing system manufacturer's specifications and installation <br />instructions. <br />