My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11/05/2019 (2)
CBCC
>
Meetings
>
2010's
>
2019
>
11/05/2019 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 12:31:10 PM
Creation date
2/6/2020 12:26:41 PM
Metadata
Fields
Template:
Meetings
Meeting Type
BCC Regular Meeting
Document Type
Agenda Packet
Meeting Date
11/05/2019
Meeting Body
Board of County Commissioners
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
355
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E N G I N E E R S <br />October 24, 2019 EXHIBIT A <br />Indian River County <br />1801 27th Street <br />Vero Beach, FL 32960 <br />Attention: Richard B. Szpyrka P.E. <br />Public Works Director <br />Reference: Proposal for Engineering Services <br />Contract Documents and Construction Administration <br />Main Library Roof Replacement <br />REI Proposal No: P18TPA-030 <br />Dear Mr. Szpyrka: <br />In response to our recent discussions, we are pleased to submit this proposal for your consideration. The roof <br />areas outlined in this proposal include roof sections of the facility located at 1600 21St Street, Vero Beach, <br />Florida 32960 (totaling approximately 29,555 square feet). The following is an outline of the proposed services <br />for Contract Documents and Construction Administration: <br />I. CONTRACT DOCUMENTS <br />A. Conduct the site visit(s) to develop detailed Contract Documents for the subject building. <br />B. Extract roof samples to identify roof system composition and condition. Cored locations to be <br />repaired with compatible materials. <br />C. Perform the following engineering design calculations for all roof areas which will be sealed by a <br />Licensed Engineer: <br />D. Determine design wind loads in accordance with ASCE 7 as required by the current edition of the <br />State Building Code. <br />E. Determine Primary drainage for compliance with the current edition of the State Plumbing Code. <br />F. Determine Existing and proposed roof system R -Value for compliance with the current edition of <br />the State Energy Conservation Code. <br />G. Estimate existing and proposed roof system dead load unit weights to determine load change and <br />the need for a structural analysis. If a structural analysis is required, REI will coordinate applicable <br />work with a licensed Structural Engineer. The cost for the structural analysis (if necessary) is not <br />included in this proposal.. <br />Engineering solutions for tomorrow" <br />10150 Highland Manor Drive, Suite 200 <br />Tampa, FL 33610 <br />PAGE f OF 3 <br />reiep i9eers.com <br />813.944.2137 <br />
The URL can be used to link to this page
Your browser does not support the video tag.