Laserfiche WebLink
Alternate Greasing Procedures: <br />Recommended a real -operation or six months of abnormal <br />operating conditions such as high speed operation (V -belt), dirty environment, high <br />pressure and temperature. <br />i. With the machine fully stopped, remove bearing cover and plugs. <br />ii. Remove all old grease; from bearings, housing and cover by flushing with a <br />clean solvent. <br />iii. Repack face of bearing by hand and add remainder of specified amount to <br />bottom half of bearing cover. <br />iv. Reinstall plugs and bearing cover and start unit. <br />Table 3: Grease <br />Full <br />Periodic Addition <br />031 1.8 oz. (45g) 1 oz. (28g) <br />051,052 3.1 oz. (87g) 2 oz. (56g) <br />081, 082, 086 5.5 oz. (154g) 3 oz. (84g) <br />23 <br />Indian River Landfill O&M Proposal Page 12 www.scsengineers.com <br />