Laserfiche WebLink
Windsor (Reclaimed Water) <br />Nutrient Loading Analysis <br />Calculate Total Phophorus Loading (TP) <br />TP = V x TP concent. mg/L x 43560cf/ac x 7.48ga1/cfx3.79L/galxlkg/106mg <br />TP = 179.20 x 1.4 mg/L x 43560cf/ac x 7.48ga1/cfx3.79L/galxlkg/106mg <br />TP = 309.40 kg/yr <br />Results <br />The existing wet detentin ponds remove approximately 40% of the Total Nitrogen and 60% of the Total <br />Phosphorus; therefore, <br />Existing <br />Reclaimed Water <br />Total <br />kg/yr <br />kg/yr <br />kg/yr <br />Total Nitrogen (TN) <br />1250 <br />482 <br />1731 <br />Total Phosphorus (TP) <br />197 <br />309 <br />507 <br />The existing wet detentin ponds remove approximately 40% of the Total Nitrogen and 60% of the Total <br />Phosphorus; therefore, <br />Windsor -Reclaimed Water.xlsx/Nutrient Loading Analysis <br />77 <br />12/19/2019 <br />Existing <br />After Removal <br />Adding <br />Reclaimed Water <br />kg/yr <br />kg/yr <br />mg/L <br />kg/yr <br />mg/L <br />Total Nitrogen (TN) <br />1250 <br />750 <br />1.53 <br />1039 <br />1.55 <br />Total Phosphorus (TP) <br />197 <br />79 <br />0.16 <br />203 <br />0.30 <br />Windsor -Reclaimed Water.xlsx/Nutrient Loading Analysis <br />77 <br />12/19/2019 <br />