My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
02/11/2020 (2)
CBCC
>
Meetings
>
2020's
>
2020
>
02/11/2020 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 1:05:23 PM
Creation date
6/17/2020 3:01:55 PM
Metadata
Fields
Template:
Meetings
Meeting Type
BCC Regular Meeting
Document Type
Agenda Packet
Meeting Date
02/11/2020
Meeting Body
Board of County Commissioners
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B. Geotechnical Investigation: <br />The geotechnical investigation will include four (4) Standard Penetration Test (SPT) borings <br />to a depth of 35 feet using a procedure similar to the Standard Penetration Test outlined in <br />ASTM D-1586. The SPT borings will be drilled at the four corners of the intersection in <br />accessible locations as close as possible to the proposed mast arm foundations. The SPT <br />borings will be sampled at 18 -inch or 24 -inch intervals to 10 feet deep and at 5 -foot <br />intervals below 10 feet. ,Each sample will be removed from the sampler in the field and <br />then examined and visually classified by our crew chief. Representative portions will be <br />sealed and packaged for transportation to our laboratory forfurther analysis as required. <br />Water level observations will be made in the boreholes during the drilling operation. For <br />the purposes of this proposal, we have assumed that maintenance -of -traffic (MOT) will not <br />be required to perform the soil borings. <br />LABORATORY TESTING <br />Routine laboratory visual classification will be performed along with specific classification <br />tests deemed necessary (i.e., sieve analysis, Atterberg limits and organic contents). All <br />laboratory tests will be performed in general accordance with applicable ASTM standards. <br />ENGINEERING ANALYSIS AND REPORT <br />Engineering analysis of all data obtained will be made to evaluate general subsurface <br />conditions, and to provide the soil parameters listed above for structural verification of the <br />standard FDOT mast arm pole design. <br />C. Signalization Plans: <br />The COUNTY desires to prepare traffic signalization plans associated with the 66th Avenue/ <br />8th Street intersection. It is understood that the proposed signalization improvements will <br />consist of a mast arm traffic signal assembly at the subject intersection which will be <br />designed to meet current IRC and FDOT standards. The plans will include the design and <br />layout of proposed signal poles, signal heads, video detection, conduit, and pull boxes. <br />The plans will include all call outs, controller timing chart, signal head details, sign details, <br />controller notes, signal operating plan, overhead street name sign design details, pole <br />schedules, tabulation of quantities. The set of plans will include the following sheets: key <br />sheet; tabulation of quantities; general notes; plan sheet; sign work sheets (if necessary) <br />and mast arm assemblies' data tables. <br />37 <br />
The URL can be used to link to this page
Your browser does not support the video tag.