My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-116D
CBCC
>
Official Documents
>
2020's
>
2020
>
2020-116D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2021 2:17:19 PM
Creation date
3/2/2021 2:15:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
06/23/2020
Control Number
2020-116D
Agenda Item Number
8.N.
Entity Name
Atlantic Roofing II of Vero Beach, Inc.
Subject
Contract Documents for Indian River County Main Library Roof Replacement
(IRC-1338) Bid No. 2020029 for Project No. IRC-1838
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
inserts, configured for insertion and sealing to existing plumbing vent piping, sized <br />to fit inside diameter of plumbing vent piping, enabling extension of piping to field - <br />determined height: <br />a. Material: Solid -wall PVC, white. <br />b. Splice Sleeve Insert: <br />i. 6 inches Length at both ends of precut extension. <br />ii. Outside Diameter to be 1/4" less than outside diameter of soil <br />pipe. <br />C. Length: <br />i. Overall Length: 28 inches. <br />ii. Net Usable Length: 16 inches excluding Splice Sleeve Inserts. <br />d. Sealant: Single -Component, Nonsag, Urethane Joint Sealant: ASTM C <br />920, Type S, Grade NS, Class 25, for Use NT, and acceptable to roofing <br />membrane manufacturer. <br />PART 3 EXECUTION <br />3.1 EXAMINATION <br />A. Survey existing conditions to determine extent of demolition. <br />B. Record the conditions of items to be removed/reinstalled and items to be removed/sal- <br />vaged. <br />C. Contractor shall not remove any element that may result in structural deficiency or collapse <br />of any part of the structure or adjacent structures during demolition. <br />D. Contractor to inspect substrate for soundness and notify Engineer in writing of any defi- <br />ciencies. Commencement of work signifies Contractor's acceptance of site conditions. <br />3.2 PREPARATION <br />A. Do not begin demolition until utilities have been disconnected/sealed and have been veri- <br />fied as such in writing. <br />B. Do not close off or obstruct streets, walks or other adjacent occupied facilities without per- <br />mission from Owner and authorities having jurisdiction. ' <br />C. Provide safe conditions for pedestrians. Erect temporary protection such as walkways, <br />fences, railings and canopies as required by OSHA and other governing authorities. <br />D. Provide protection for adjacent building, appurtenances and landscaping to remain. Erect <br />temporary fencing around trees to remain. <br />E. Provide temporary weather protection as required to prevent water leakage and damaged <br />to exterior or interior of adjacent structures. <br />3.3 UTILITIES/SERVICES <br />A. Maintain existing utilities that are to remain in service and protect them against damage <br />during selective site demolition unless authorized in writing by the Owner and authorities <br />having jurisdiction. <br />IRC -1838 Indian River County <br />Main Library <br />Roof Replacement 07 01 50-3 Preparation for Reroofing (Revision 1) <br />