Laserfiche WebLink
Reinforcing/Stripping Ply (Torch Application): <br />a. Firestone SBS Poly Torch Base <br />b. GAF Ruberoid SBS Heat Weld Smooth <br />C. JM Dynabase HW <br />d. Siplast Paradiene 20 TG <br />2. Flashing/Target Ply (Torch Application): <br />a. Firestone SBS Premium FR Torch <br />b. GAF SBS Heat Weld Plus FR <br />C. JM Dyanweld Cap 180 FR <br />d. Siplast Parafor 50 LT <br />D. Fluid Applied Flashing System: Shall be membrane manufacturer's polyurethane or PMMA <br />based resin with polyester fleece flashing system. <br />1. Firestone Ultraflash Liquid Flashing <br />2. GAF Topcoat <br />3. JM SeamFree PMMA Liquid Membrane <br />4. Siplast Parapro <br />2.3 RELATED MATERIALS <br />A. Asphalt: Shall be certified for full compliance with the requirements for Type III asphalt <br />listed in Table 1, ASTM D-312. Each container or bulk shipping ticket shall indicate the <br />equiviscous temperature (EVT), the finished blowing temperature (FBT), and the flash point <br />(FP). <br />B. Asphalt primer: Shall meet ASTM D-41 requirements and be approved for intended use by <br />membrane manufacturer. <br />C. Flashing Cement: An asphalt cutback mastic, reinforced with non -asbestos fibers, <br />enhanced slump resistance, used for all flashing and vertical applications conforming to <br />ASTM D 4586 Type II requirements. <br />1. Firestone Multi -Purpose MB Flashing Cement <br />2. GAF 202 Flashing Cement <br />3. JM MBR Flashing Cement <br />4. Siplast PA 828 <br />D. Solvent Free Adhesive: A single component, solvent -free modified asphalt adhesive <br />designed for application of the specified roof membrane in areas below the fluid applied <br />flashing. <br />E. Utility Roof Cement: An asphalt cutback general utility mastic, reinforced with non - <br />asbestos fibers, used as a base for setting metal flanges and temporary seals conforming <br />to ASTM D 4586 Type II requirements. <br />F. Sealant: An SBS polymer modified asphaltic flashing cement in a 10.4 -ounce cartridge <br />conforming to ASTM 4586 requirements approved by the roofing membrane manufacturer <br />for use in conjunction with the roofing membrane materials. <br />G. Ceramic granules: Shall be of color scheme matching the granule surfacing of the cap <br />sheet comparable to No. 11 granules. <br />H. Adhesive and Bitumen Overrun Surfacing (Cool Roof). Approved Products: <br />IRC -1838 Indian River County <br />Main Library <br />Roof Replacement 07 52 16-5 Modified Bitumen Roofing (Revision 1) <br />