My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-082F
CBCC
>
Official Documents
>
2020's
>
2021
>
2021-082F
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2021 10:05:43 AM
Creation date
7/19/2021 2:32:10 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
06/08/2021
Control Number
2021-082F
Agenda Item Number
8.V.
Entity Name
Atlantic Roofing II of Vero Beach, Inc.
Subject
Courthouse Roof Replacement
Project Number
IRC-1764
Bid Number
2021036
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
305
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY COURTHOUSE PAGE 5 <br />METAL ROOFING REPLACEMENT PROJECT SECTION 076200 <br />JANUARY 15, 2021 SHEET METAL AND FLASHINGS <br />2.5 FABRICATION, GENERAL <br />A. Custom fabricate sheet metal flashing and trim to comply with details indicated and <br />recommendations in cited sheet metal standard that apply to design, dimensions, <br />geometry, metal thickness, and other characteristics of item required. <br />1. Fabricate sheet metal flashing and trim in shop to greatest extent possible. <br />2. Fabricate sheet metal flashing and trim in thickness or weight needed to comply <br />with performance requirements, but not less than that specified for each <br />application and metal. <br />3. Verify shapes and dimensions of surfaces to be covered and obtain field <br />measurements for accurate fit before shop fabrication. <br />4. Form sheet metal flashing and trim to fit substrates without excessive oil -canning, <br />buckling, and tool marks; true to line, levels, and slopes; and with exposed edges <br />folded back to form hems. <br />5. Conceal fasteners and expansion provisions where possible. Do not use <br />exposed fasteners on faces exposed to view. <br />B. Fabrication Tolerances: <br />1. Fabricate sheet metal flashing and trim that is capable of installation to a <br />tolerance of 1/4 inch in 20 feet (6 mm in 6 m) on slope and location lines <br />indicated on Drawings and within 1/8 -inch (3 -mm) offset of adjoining faces and of <br />alignment of matching profiles. <br />2. Fabricate sheet metal flashing and trim that is capable of installation to <br />tolerances specified. <br />C. Expansion Provisions: Form metal for thermal expansion of exposed flashing and trim. <br />1. Use lapped expansion joints only where indicated on Drawings. <br />D. Sealant Joints: Where movable, nonexpansion-type joints are required, form metal in <br />accordance with cited sheet metal standard to provide for proper installation of <br />elastomeric sealant. <br />E. Fabricate cleats and attachment devices from same material as accessory being <br />anchored or from compatible, noncorrosive metal. <br />F. Fabricate cleats and attachment devices of sizes as recommended by cited sheet <br />metal standard for application, but not less than thickness of metal being secured. <br />G. Seams: <br />Tin edges to be seamed, form seams, and solder. <br />2.6 ROOF -DRAINAGE SHEET METAL FABRICATIONS <br />A. Hanging Gutters: <br />Fabricate to cross section required, complete with end pieces, outlet tubes, and <br />other accessories as required. <br />