My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-014
CBCC
>
Official Documents
>
2020's
>
2022
>
2022-014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2022 3:10:24 PM
Creation date
2/21/2022 3:09:22 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
01/18/2022
Control Number
2022-014
Agenda Item Number
15.B.2.
Entity Name
Geosyntec Consultants, Inc
Subject
Work Order No. 14 for Annual Permit, Compliance Monitoring, and Reporting for 2022.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Himanshu H. Mehta, P.E. <br />14 December 2021 <br />Page 2 <br />19 acres is comprised of Cell 1 C&D debris disposal facility, and 2.5 acres consists of a C&D <br />debris recycling facility. <br />The Class I landfill currently accepts both Class I waste and C&D debris for disposal under the <br />Florida Department of Environmental Protection (FDEP) Construct and Operate Permit <br />Modification Nos. 0128769 -026 -SC -IM and 0128769 -027 -SO -MM, dated April 2, 2018 (Class I <br />Permit). The C&D debris disposal facility operates under FDEP Permit No. 0128769 -025 -SO - <br />24, dated July 13, 2017 (C&D Permit). <br />Semi -Annual Water Quality Compliance Monitoring and Reporting <br />The Water Quality Monitoring Plan (WQMP) for each of the IRCL facilities permits (which is <br />listed as Appendix 3 of each permit) indicates that groundwater and surface water quality <br />monitoring are required. Semi-annual sampling of the Class I landfill and C&D debris disposal <br />facility groundwater monitoring wells shall be conducted in January and July 2021. The samples <br />collected from the Class I landfill and C&D debris disposal facility monitoring wells shall be <br />analyzed for the routine monitoring parameters listed in Section II.3 (Class I Permit) and <br />Paragraph 8 (C&D Permit) of the WQMP, respectively, as required by paragraphs 62- <br />701.510(5)(c) & (7)(a) and 62-701.730(8)(d), Florida Administrative Code (F.A.C.). Samples <br />from one surface water monitoring site (SW -2) shall be collected semi-annually in January and <br />July, if water is discharging from the stormwater pond. The samples, if collected, shall be <br />analyzed for the list of parameters listed in Section III.2 of the Class I Landfill WQMP, as <br />required by paragraphs 62-701.510 (5)(d) and (7)(b), F.A.C. <br />Geosyntec will perform the field sampling activities, and the analytical testing will be conducted <br />by ENCO Laboratories (ENCO) of Orlando, Florida, the analytical laboratory contracted with, <br />and direct bill to, SWDD. The results of the annual and semi-annual water -quality monitoring <br />events are to be reported to FDEP within 60 days of receipt of analysis from the laboratory. <br />Quarterly Assessment Monitoring for the C&D Debris Disposal Facility <br />Geosyntec understands that results of routine sampling of C&D debris disposal facility <br />groundwater monitoring well (MW -21S) in January 2017 indicated exceedances of benzene and <br />sodium groundwater cleanup target levels (GCTLs). As a result, SWDD was requested by FDEP <br />to initiate evaluation monitoring in accordance with subsection 62-701.510(6), F.A.C. Pursuant <br />to this request SWDD installed one groundwater monitoring well (MW -49S) in July 2017. <br />These and other wells (MW -21S, MW -33S, MW -35S, MW -405, MW -49S, MW -505, MW -51S, <br />and MW -52S) and seven surface water (SW) Lateral Canal (LC) sample sites (SW -LCI, SW- <br />LC2, SW-LC3, LC-SW4, LC-SW5, LC-SW6, and LC-SW8) have been sampled quarterly from <br />July 2017 to October 2020 under an evaluation monitoring program with FDEP. However, in <br />NCP2021-3441/JL21090 2022 Compliance Monitoring Proposal,Final.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.