My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1968-009
CBCC
>
Resolutions
>
1960's
>
1968
>
1968-009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2022 11:00:17 AM
Creation date
4/22/2022 10:57:07 AM
Metadata
Fields
Template:
Resolutions
Resolution Number
1968-009
Approved Date
02/21/1968
Resolution Type
Adopting a Building Code
Subject
Adopting Building Code, Electrical & Plumbing Codes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
equipment and its control devices, terminal equipment for telephone <br />service (in separate area from electrician's area) and all the electric <br />meters which serve the occupants throughout the entire building. The <br />construction of this room shall conform to the same type of material <br />and construction as the main building, and there shall be no storage <br />of any kind, gas meters or water heaters permitted In this room. <br />(g) Service disconnecting switches must be located In a con- <br />venient and readily accessible place Inside the building when a meter <br />room Is not available. The service disconnecting switch or switches, <br />and other disconnecting equipment located in enclosed or semi - <br />enclosed porches not exposed to the weather, shall be considered as <br />being located inside the building. <br />(h) Service disconnect shall be located at the nearest point of <br />service entry not to exceed 25 feet and shall not be installed In bath- <br />rooms, bedrooms, closets or kitchen cabinets, <br />(I) All 220 volt circuits must be protected with cartridge fuses <br />or double pole breakers, <br />(J) All main switches and sub -main switches shall be plainly <br />marked so that the division, sub -division, or separate occupancies <br />of the building which they control can be quickly and positively Identi- <br />fied. The mark of identification shall be securely affixed to the switch <br />to prevent its loss or misplacement. <br />(k) All service grounds shall be equipped with ground rods, <br />not less than 8 ft. In length. Water pipe systenis will not be allowed. <br />(1) The service and equipment ground must be taken from the <br />nearest possible point of the system service after the service is <br />attached to the building. This ground must start at the meter socket, <br />main switch or C. T. can. Point of attachment of ground clamps or <br />approved ground connectors shall be readily accessible, and shall not <br />be in attics, under floor or behind any equipment. <br />23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.