My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-232
CBCC
>
Official Documents
>
2020's
>
2023
>
2023-232
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2023 10:33:32 AM
Creation date
11/9/2023 10:32:24 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
10/17/2023
Control Number
2023-232
Agenda Item Number
8.I.
Entity Name
Transportation (FDOT)
Subject
Small County Outreach (SCOP) State-Funded Agreement for Construction & CEI
of 43rd Avenue (12th Street to 18th Street)
FM NO. 444270-1-54-01
Bid Number
IRC-1818
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Deliverables Exhibit A <br />444270-1-54-01 <br />43RD AVENUE FROM 12TH STREET TO 18TH STREET <br />Pay Item <br />Pay Item Description <br />Quantity <br />Unit <br />101-1 <br />MOBILIZATION/ DEMOBILIZATION <br />1 <br />LS <br />102-1 <br />MAINTENANCE OF TRAFFIC <br />1 <br />LS <br />PREVENTION, CONTROL & ABATEMENT OF EROSION AND WATER <br />104-2 <br />POLLUTION <br />1 <br />LS <br />110-1-1 <br />CLEARING & GRUBBING <br />5.75 <br />AC <br />120-1 <br />REGULAR EXCAVATION <br />2424 <br />CY <br />120-6 <br />EMBANKMENT <br />3034 <br />CY <br />160-4 <br />TYPE'B' STABIUZATION <br />8400 <br />SY <br />285-706 <br />OPTIONAL BASE GROUP 06 (CEMENTED COQUINA, LBR 100, 8") <br />5235 <br />SY <br />285-716 <br />OPTIONAL BASE GROUP 18 (CEMENTED COQUINA, LBR 100, 18") <br />300 <br />SY <br />327-70-13 <br />MILLING EXISTING ASPHALT PAVEMENT (1.7V) <br />12330 <br />SY <br />334-1-13A <br />SUPERPAVE ASPHALT CONCRETE (SP -12.5) (TRAFFIC C) (1.5") <br />1581 <br />TN <br />ASPHALTIC CONCRETE FRICTION COURSE (FC -9.5) (TRAFFIC C, PG 76-22) <br />337-7-82 <br />(1.0") <br />1060 <br />TN <br />400-0-11 <br />CLASS NS CONCRETE (GRAVITY WALL) (SCHEME 2) <br />270 <br />CY <br />400-153 <br />NON -SHRINK GROUT <br />265 <br />CF <br />400-2-1A <br />CONCRETE, CLASS II (4,000 PSI) (CONCRETE COLLARS) <br />4 <br />EA <br />425-1-521 <br />INLETS, DT BOT, TYPE'C', < 10' <br />12 <br />EA <br />425-1-521A <br />INLETS, DT BOT, TYPE'C' W/ P -BOTTOM, <10' <br />3 <br />EA <br />425-1-541 <br />INLETS, DT BOT, TYPE'D', < 10' <br />2 <br />EA <br />425-1-551 <br />INLETS, DT BOT, TYPE'E', <10' <br />25 <br />EA <br />425-2-41 <br />MANHOLE, TYPE 7 W/ P -BOTTOM (<10') (w/ 3' DIA. RING & COVER) <br />4 <br />EA <br />425-2-61 <br />MANHOLE, TYPE 8 W/ P -BOTTOM (<10') (w/ 3' DIA. RING & COVER) <br />3 <br />EA <br />425-6 <br />ADJUST VALVE BOX <br />10 <br />EA <br />430-175-118 <br />PIPE CULVERT, ROUND, 18" REINFORCED CONCRETE PIPE (CL III), S/CD <br />1284 <br />LF <br />430-175-124 <br />PIPE CULVERT, ROUND, 24" REINFORCED CONCRETE PIPE (CL III), S/CD <br />3612 <br />LP <br />PIPE CULVERT, ROUND, 24" CORRUGATED ALLUMINUM PIPE (12 GAUGE), <br />430-175-124A <br />S/CD <br />40 <br />LF <br />430-175-130 <br />PIPE CULVERT, ROUND, 30" REINFORCED CONCRETE PIPE (CL III), S/CD <br />455 <br />LF <br />430-175-160 <br />PIPE CULVERT, ROUND, 60" REINFORCED CONCRETE PIPE (CL III), S/CD <br />136 <br />LF <br />PIPE CULVERT, ELLIPTICAL 12"x1.8" REINFORCED CONRETE PIPE (CL III), <br />430-175-215 <br />S/CD <br />40 <br />LF <br />430-982-125 <br />MITERED END SECTION (18" ROUND) (4:1) (CD) <br />2 <br />EA <br />430-984-623 <br />MITERED END SECTION (12"x18" ELLIPTICAL) (4:1) (SD) <br />2 <br />EA <br />515-1-2 <br />PIPE HANDRAIL - GUIDERAIL (AWMINUM) <br />840 <br />LF <br />520-1-10 <br />CONCRETE CURB AND GUTTER (TYPE F) (3000 PSI MIN.) <br />203 <br />LF <br />CONCRETE SIDEWALK AND DRIVEWAYS (6" THICK) (FIBER REINFORCED) <br />522-2 <br />(3000 PSI MIN.) <br />5080 <br />SY <br />527-2 <br />DETECTABLE WARNINGS <br />576 <br />SF <br />530-3-4 <br />RIPRAP - RUBBLE (F&I) (DITCH LINING) <br />175 <br />TN <br />570-1-1 <br />PERFORMANCE TURF (SOD) (BAHIA) <br />33200 <br />SY <br />630-2-11 <br />CONDUIT, F&I, OPEN TRENCH <br />128 <br />LF <br />630.2-12 <br />CONDUIT, F&I, DIRECTIONAL BORE <br />190 <br />LF <br />630-2-12A <br />CONDUIT (F&I) (DIRECTIONAL BORE) (2-2" PVC) <br />2625 <br />LF <br />630-2-14 <br />CONDUIT, F&I, ABOVEGROUND <br />40 <br />LF <br />CONDUIT (RELOCATE CONDUIT WITH FIBERNVIRE REMAINING <br />630-2-100 <br />OPERATIONAL) <br />50 <br />LF <br />632-7-1 <br />SIGNAL CABLE F&I <br />2 <br />PI <br />632-7-6 <br />SIGNAL CABLE, REMOVE- INTERSECTION <br />2 <br />PI <br />633-1-124 <br />FIBER OPTIC CABLE (F&I) (UNDERGROUND) (144 STRAND) <br />3025 <br />LP <br />633-2-31 <br />FIBER OPTIC CONNECTION (F&I) (SPLICE) <br />192 <br />EA <br />633-2-32 <br />FIBER OPTIC CONNECTION (F&I) (TERMINATION) <br />96 <br />EA <br />
The URL can be used to link to this page
Your browser does not support the video tag.