Laserfiche WebLink
7. <br />Pursuant to county LDRs [911.17(4)(a)], the project site plan <br />cannot be released until an "airport construction permit" is <br />issued by county staff. <br />Building Area: -317 sq. ft. (unmanned, electrical equipment <br />building) <br />8. Open Space: Required: 80.08 <br />Provided: 81.38 <br />9. Traffic Circulation: The site's existing driveway to Minute <br />-Maid Road will provide access to the site of the proposed <br />tower. Use of the existing driveway for the project has been <br />approved by the county traffic engineer. <br />10. Off -Street Parking: Required: 2 unpaved <br />Provided: 2 unpaved <br />Note: County off-street parking regulations for towers <br />require two (2) parking spaces. The spaces may be fully <br />sodded or otherwise stabilized as approved by the Public Works <br />Director. The stabilized parking spaces provided for the <br />subject site have been approved by the Public Works Director. <br />11. Landscape Plan: For towers, such as this one, that exceed <br />140' in height in agricultural zoning districts, the lowest <br />50' of the tower must be .screened from adjacent properties. <br />The existing grove and tree line along the perimeter of the <br />grove will provide the required screening initially. However, <br />in order to ensure future screening from Oslo Road, in the <br />event the grove trees are removed in the future, oak trees are <br />proposed to be planted along the northern perimeter of the <br />lease area for the tower. Therefore, the specific land use <br />criteria of section 971.44(2) is satisfied. <br />12. Stormwater Management: The Stormwater Management Plan has <br />been approved by the Public Works Department. <br />13. Utilities: The proposed site is outside of the utilities <br />service area. Given 'the type of use, no water or wastewater <br />services are required. Therefore, county utilities has no <br />objection to approval of the site plan and use request. <br />14. Health 6 Rehabilitative Services (HRS): The HRS Environmental <br />Health Unit .acknowledges that the site will not require a <br />potable water supply or sanitary facility, and has no <br />objections to approval of the site plan and use request. <br />15. Specific Land Use Criteria: The applicant must satisfy the <br />following specific land use criteria which apply to the <br />erection of a tower exceeding 140' in height within a A-2 <br />zoning district. <br />A. General criteria for all towers exceeding 70' in height. <br />1. All towers shall have setbacks from all property <br />lines equal to one hundred ten (110) percent of the <br />height of the proposed structure. This provision <br />may be waived or modified upon a recommendation by <br />the director of public works, based upon the <br />following criteria. <br />a: The 'designed fall radius of the tower is <br />depicted on the.site plan and does not impact <br />adjacent uses; <br />b. A certified, signed and sealed statement from <br />a Florida registered professional engineer <br />states that the tower would collapse within <br />the designed and specified fall radius <br />depicted on the plans. <br />2. In no case shall the fall radius (one hundred ten <br />(110) percent of height or other approved design <br />fall radius) encroach upon existing off-site <br />structures or residentially designated property; <br />Note: The tower's fall radius covers an area <br />larger than the tower lease area. Prior to site <br />plan release, the applicant will need to document. <br />to the satisfaction of the county attorney's <br />AUGUST 13, 1996 41 .Boos <br />98 Fir. Y <br />