My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024-044
CBCC
>
Official Documents
>
2020's
>
2024
>
2024-044
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2024 12:41:32 PM
Creation date
3/7/2024 12:39:29 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Amendment
Approved Date
02/20/2024
Control Number
2024-044
Agenda Item Number
8.L.
Entity Name
Masteller & Moler, Inc.
Subject
Amendment No. 2 to Work Order No. 14 for North County Spoonbill Marsh River Intake Station
Access WWTF 24” Force Main Replacement IRCDUS Proj. ID 21.23.503
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MJ MASTELLER & MOLER, INC. <br />M 1 —CIVIL ENGINEERS — <br />1655 27" S <br />Ste. 2, Vero Beach, FL 32960 <br />(772) 567-5300 <br />E. Submittal of RAI Responses: Atlantic Environmental will prepare the environmental <br />responses to 2 FDEP RAls, including, but not limited to, narrative descriptions of impacts and <br />proposed mitigation, site plan, associated environmental maps and figures, and, monitoring <br />plan and schedule. Atlantic Environmental will coordinate with IRC Staff, the project <br />engineer, and FDEP to obtain all information necessary for the completion of the responses. <br />F. Coordination: Complete necessary coordination between IRC Staff, the project engineer, and <br />remaining project team in order to speed permitting process and avoid costly time delays. <br />USACE Environmental Permitting: <br />G. UMAM Analysis (IF REQUIRED) or Development of Restoration Plan of Temporary Impacts: <br />Based on the site inspections and coordination with the USACE, Atlantic Environmental will <br />develop a UMAM analysis for the expected Temporary wetland impacts associated with the <br />installation of the new buried electrical power system. If no mitigation is required, Atlantic <br />Environmental will develop a restoration plan of temporary impacts. <br />H. Development of Mitigation Plan (IF REQUIRED): Atlantic Environmental will coordinate with <br />IRC Staff, project engineer, and USACE to develop a mitigation plan for the temporary <br />wetland impacts including conducting meetings with these agencies and IRC/engineer. <br />I. Site Meeting: Atlantic Environmental will conduct, if required, an on-site meeting at the <br />project site with USACE to allow their assessment of the project, as well as the completion <br />of the UMAM Analysis. <br />J. Application: Based on information obtained from the regulatory agencies and the client, <br />Atlantic Environmental will prepare the environmental portions of the necessary USACE <br />Permit Application(s), including all necessary forms, narratives, mitigation plans, maps, <br />tables, and UMAM data sheets. <br />K. Submittal of RAI Responses: Atlantic Environmental will prepare the environmental <br />responses to 2 USACE RAIs, including, but not limited to, narrative descriptions of impacts <br />and proposed mitigation, site plan, associated environmental maps and figures, and, <br />monitoring plan and schedule. Atlantic Environmental will coordinate with IRC Staff, the <br />project engineer, and USACE to obtain all information necessary for the completion of the <br />responses. <br />L. Coordination: Complete necessary coordination between IRC Staff, the project engineer, and <br />remaining project team in order to speed permitting process and avoid costly time delays. <br />Task 1D — Soils Investigation (by KSM Engineering & Testing) <br />We shall acquire soil borings along the intended route of the new buried electric power supply <br />to obtain the type of soils conditions for use by the selected underground utility contractor for <br />the project. Consultant shall provide for the required Geotechnical Engineering Services to be <br />performed by subconsultant KSM Engineering & Testing to include the following services in <br />accordance with the Industry Standard of Care and the current Florida Building Code: <br />Page 3 of 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.