2000-125
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-125
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2024 1:44:12 PM
Creation date
3/22/2024 1:44:08 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Miscellaneous
Approved Date
04/18/2000
Control Number
2000-125
Agenda Item Number
12.H.3.
Entity Name
American Compliance Technologies, Inc.
Subject
Repairs to Acid Tank Leak South County Reverse Osmosis
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />• <br />Scope of Work <br />Cost E6111"at9 - "2SO4 AST Repair <br />3798.00 <br />SCOPE -OF -WORK: <br />March 23, 2000 <br />Page 1 of 2 <br />The identified project is to effect the repair of a leaking 16,000 -gallon H,SO, <br />AST. After performing an inspection of the AST It has been determined that the <br />course of action will need to hr: tho tompornry storage of approximately 8,000 <br />gallons of 98% H,SO, for approximately two weeks while the AST is cleaned, <br />inspected, and repaired, Temporary storage of the 98% H,SO, will be in 2,000 - <br />gallon poly tanks suitable for short-term acid use (i e , less than three years <br />continuous contact). However, the poly tanks will need to be fitted with CPVC <br />fittings sealed with VIl ON 0 -rings prior to being put into service as temporary <br />acid storage. ACT will provide for Indian River County's use a double-diaphragrn <br />acid purnp to transfer acid to day tank during AST work. <br />The AST will be cleaned of residual acid and washed with a 3,000 psi pressure <br />washer. Once the tank interior is cleaned the interior surface will be visually <br />examined for pitting, corrosion, and/or cracks. In addition, the steel tank shell <br />will be inspected at randomly selected locations with an ultrasonic thickness <br />gauge to measure tank wall thickness. Following all tank inspections the leaking <br />pipe nipple underneath the tank will be cut away with a new nipple and flange <br />welded into place. <br />After the tank has been repaired the remaining H,SO, in temporary storage will <br />be returned to the AST. The poly tanks will be cleaned on site after all acid has <br />been transferred to the AST. <br />DESCRIPTION <br />UNITS <br />QTY. <br />UNIT <br />TOTAL <br />COST <br />Transfer H,SO, and Clean <br />lump <br />1 <br />$4,262.00 <br />$4,262.00 <br />16,000 -Gallon AST <br />sum <br />Temporary Acid Storage <br />2,000 -Gallon Poly Tanks <br />week <br />2 <br />$120.00 <br />$960.00 <br />CPVC Tank Fitting Upgrade <br />each <br />4 <br />$250.00 <br />$1,000.00 <br />Acid Diaphragm Pump <br />week <br />2 <br />$342.00 <br />$684.00 <br />Poly Tank Gleaning <br />each <br />4 <br />$225.00 <br />$90000 <br />Tank Interior Visual and Ultrasonic <br />lump <br />1 <br />$1,995.00 <br />$1,995.00 <br />i2ilaeettonsum <br />Tank Repair <br />lump <br />1 <br />$650.00 <br />$650.00 <br />Sum <br />Total <br />$10,451.00 <br />V0' d E:C 1 1 VES 299=G1 <br />A*C*T <br />IM:3.1. di•100 NW) IH314V 6 V : Z 1 00-£:Z.-00 <br />