My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-337A
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-337A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 11:58:02 AM
Creation date
8/13/2024 11:57:31 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Application
Approved Date
11/07/2000
Control Number
2000-337A
Agenda Item Number
11.B.
Entity Name
State of Florida Department of Community Affairs
Subject
Hazard Mitigation Grant Program Application for Shelter Retrofit Projects
Sebastian River High School
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
40 <br />40 <br />40 <br />the categories of preferred, marginal and non-compliant. <br />Preferred characteristics of this facility include: <br />• The buildings and its' access road are located outside the Category 5 storm surge innundation. <br />• The buildings and its' access road are located outside the 500 -year floodplain (Zone 7Q. <br />• A clearly defined, continuous loadpath from roof to foundation is present. <br />• The building was in good condition with no apparent signs of deterioration. <br />• The buildings' exterior walls are constructed of fully reinforced masonry. <br />• No evidence of degradation is present on roof. <br />No verification of wind parameters used in desig but a 1992 design generally meets high wind <br />requirements. <br />Marginal characteristics of this facility include: <br />• The building has a lightweight roof system. <br />• The building is within the Vulnerability Zone of two Section 302 facilities but with low release <br />potential. <br />• The building has unprotected windows and doors that lead into shelter areas. <br />Non-compliant characteristic of this facility include: <br />• Several hazards within lay -down range of building. <br />The building has a roof span that exceeds 40 feet. <br />Retrofit Recommendation: <br />Ma <br />j r <br />• Have a structural engineer evaluate roof system to determine modifications required to resist <br />uplift and bending forces. <br />• Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTD 12-94 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4). <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />• Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />• Secure portable classrooms and mobile homes on the site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.