My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-337E
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-337E
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 12:14:55 PM
Creation date
8/13/2024 12:07:43 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Application
Approved Date
11/07/2000
Control Number
2000-337E
Agenda Item Number
11.B.
Entity Name
State of Florida Department of Community Affairs
Subject
Hazard Mitigation Grant Program Application for Shelter Retrofit Projects
Fellsmere Elementary
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WO <br />Conclusions; <br />When analyzed using the criteria outlined in the ARC 4496 Least -Risk Decision Matting Guideline <br />Compliance Summary, Fellsmere Elementary School was found to have characteristics which fail under <br />the categories of preferred, marginal and non-compliant. <br />Preferred characteristics of this facility include: <br />The building and its access road are located outside the Category 5 storm surge inundation. <br />• The building and its access road are located outside the 540 -year floodplain (Zone X). <br />• A clearly defined, continuous ioadpath from roof to foundation is present. <br />• The building is in good condition with no apparent signs of deterioration. <br />• The buildings' exterior walls are constructed of fully reinforced masonry. <br />+ <br />No evidence of degradation is present on roof. <br />• An Emergency Standby Power Generator exists on site. <br />Marginal characteristics of this facility include: <br />+ There is limited exposure to large and small wind-borne debris. <br />The wind design standard used but no apparent flaws were noted. <br />• The building has a flat, lightweight roof system. <br />• Minimal hazards within lay -down range of building. <br />Non-compliant characteristic of this facility include: <br />• The building has unprotected windows and doors that lead into shelter areas. <br />Retrofit Recommendation; <br />T <br />Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTD 12-94 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4), <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />• Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />
The URL can be used to link to this page
Your browser does not support the video tag.