Laserfiche WebLink
WO <br />Conclusions; <br />When analyzed using the criteria outlined in the ARC 4496 Least -Risk Decision Matting Guideline <br />Compliance Summary, Fellsmere Elementary School was found to have characteristics which fail under <br />the categories of preferred, marginal and non-compliant. <br />Preferred characteristics of this facility include: <br />The building and its access road are located outside the Category 5 storm surge inundation. <br />• The building and its access road are located outside the 540 -year floodplain (Zone X). <br />• A clearly defined, continuous ioadpath from roof to foundation is present. <br />• The building is in good condition with no apparent signs of deterioration. <br />• The buildings' exterior walls are constructed of fully reinforced masonry. <br />+ <br />No evidence of degradation is present on roof. <br />• An Emergency Standby Power Generator exists on site. <br />Marginal characteristics of this facility include: <br />+ There is limited exposure to large and small wind-borne debris. <br />The wind design standard used but no apparent flaws were noted. <br />• The building has a flat, lightweight roof system. <br />• Minimal hazards within lay -down range of building. <br />Non-compliant characteristic of this facility include: <br />• The building has unprotected windows and doors that lead into shelter areas. <br />Retrofit Recommendation; <br />T <br />Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTD 12-94 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4), <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />• Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />