Official Document Type
Application
Approved Date
11/07/2000
Control Number
2000-337I
Agenda Item Number
11.B.
Entity Name
State of Florida Dept. of Community Affairs
Subject
Hazard Mitigation Grant Program Application for Shelter Retrofits Projects
Sebastian River Middle
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
40 <br />• <br />40 <br />• The building is in good condition with no apparent signs of deterioration. <br />• The building's exterior walls are constructed of fully reinforced masonry. <br />• No evidence of degradation is present on roof. <br />• An Emergency Standby Power Generator exists on site. <br />Marginal characteristics of this facility includes <br />• No verification of wind parameters used in design but no apparent flaws were noted. <br />• The building has a flat, lightweight roof system. <br />• The building is within the Vulnerability Zone of two Section 302 facilities but with low release <br />potential. <br />• The structure provides no interior safe space. <br />Non-compliant characteristic of this facility include: <br />• Several hazards within lay -down range of building. <br />• The building has unprotected windows and doors that lead into shelter areas. <br />• The building's roof exceeds a 40 foot span. <br />Retrofit Recommendation: <br />• Have a structural engineer evaluate roof system to determine modifications required to resist <br />uplift and bending forces. Roof span exceeds 40 feet. <br />• Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTs] 12-44 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4). <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />