My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-337J
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-337J
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2024 10:57:34 AM
Creation date
8/15/2024 10:56:31 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Application
Approved Date
11/07/2000
Control Number
2000-337J
Agenda Item Number
11.B.
Entity Name
State of Florida Dept. of Community Affairs
Vero Beach High School
Subject
Hazard Mitigation Grant Program Application for Shelter Retrofits Projects
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E�] <br />A"M IA N 21 <br />CRITERIA <br />PREFERRED MARGINAL <br />NON- <br />COMPLIANT <br />6. Wind Design <br />No verification of wind <br />Verification <br />parameters <br />parameters used in <br />Building <br />designed in 1465 and no <br />plans available to verify <br />reinforcement. <br />7. Construction Type <br />Clearly defined and <br />1 Loadpadi <br />confinuoxs loadpath <br />Verification <br />from roof to foundarion <br />is provided by columns <br />and spandrel beanrs <br />8. Building Condition <br />The building shows <br />signs of minor <br />deterioration <br />9. Exterior Wall <br />Partially reinforced <br />Construction <br />CMU <br />10. Fenestrations 1 <br />Unprotected windows <br />Window Protection <br />and doors; doors are <br />metal security type; <br />direct exposure to <br />shelter area &: less than <br />10% window area <br />11. Roof Construction <br />The building has a flat, <br />1 Roof S1ope <br />lightweight roof with <br />engineered mechanical <br />connections to support <br />structures below. <br />12. Roof Open Span <br />The build'utg has a roof <br />system with distances <br />between vertical <br />supports that are greater <br />than 40 feet <br />13. Roof Drainage 1 <br />No evidence of ponding <br />Ponding <br />or degredation is present <br />on roof <br />14. Interior Safe <br />NIA <br />Space <br />15. Life Safety/ <br />An Emergency Standby <br />Emergency Power <br />Power Generator exists <br />on site. <br />Italicized teems revised 6111100 at request of Indian River County <br />
The URL can be used to link to this page
Your browser does not support the video tag.