Laserfiche WebLink
MOUNT REINFORCEMENT DRAWINGS <br />PREPARED FOR AT&T <br />SITE NAME: WEST VERO <br />SITE NUMBER: FLFPU1005 <br />FA#: 10032101 <br />SITE ADDRESS: <br />5850 COLLEGE LANE, VERO BEACH.. <br />INDIAN RIVER COUNTY, FL 32966 <br />QUALIFIED ENGINEERING SERVICES ARE AVAILABLE FROM <br />MASTEC NETWORK SOLUTIONS TO ASSIST CONTRACTORS IN <br />CLASS IV RIGGING PLAN REVIEWS. FOR REQUESTED <br />QUALIFIED ENGINEERING SERVICES, PLEASE CONTACT <br />RAPHAEL MOHAMED AT (919) 2445207. <br />PROJECT CONTACTS: <br />1. PROJECT MANAGER <br />ARNALDO CARRASQUILLO <br />787-477-3414 <br />ARNALDO.CARRASQ UILLO@MASTEC.COM <br />2. DESIGN ENGINEER - MAIN RFI CONTACT <br />VLADIMIR BLANCHARD <br />VLADI MI R. BLANCHARD@MASTEC.COM <br />3. ENGINEER OF RECORD <br />RAPHAEL I. MOHAMED, PE, PEng <br />919-674-5895 <br />1151 SE CARY PKWY <br />SUITE 101 <br />CARY, NC 27518 <br />RAP HAE L. M O HAM E D@ MAST E C. C O M <br />4. FOR FABRICATION AND CONSTRUCTION <br />RELATED INQUIRIES: CONTACT MASTEC <br />DESIGN ENGINEER AND ENGINEER OF RECORD. <br />TOWER INFORMATION <br />TOWER HEIGHT / TYPE 155 FT WATER TANK TOWER <br />MOUNT HEIGHT/TYPE: 106 FT RAD CENTER <br />TOWER LOCATION: LAT: 27.6354° <br />LONG: -80.4485° <br />PREVIOUS ANALYSIS FIRM NAME: MASTEC NETWORK SOLUTIONS <br />PROJECT NUMBER: 43368-MNT1 <br />PASSING ANALYSIS FIRM NAME: MASTEC NETWORK SOLUTIONS <br />PROJECT NUMBER: 43368-MMD2 <br />CODE COMPLIANCE <br />ANSI/TIA-222-H <br />2023 FLORIDA BUILDING CODE, 8TH EDITION <br />DRAWINGS INCLUDED <br />SHEOET <br />DESCRIPTION SNOT DESCRIPTION <br />T-1 <br />TITLE SHEET <br />N-1 <br />MODIFICATION INSPECTION CHECKLIST <br />N-2 <br />GENERAL NOTES <br />S-1 <br />MODIFICATION SCHEDULE <br />S-2 <br />MOUNT PIPE INSTALLATION DETAILS <br />S-3 <br />I STANDOFF MOUNT INSTALLATION DETAILS <br />A-1 <br />MANUFACTURER SPECIFICATIONS I <br />` •`,O <br />MNS ENG. NUMBER. 43368-MMD1 <br />i <br />82M <br />SITE ADDRESS'. <br />5850 COLLEGE LANE. VERO BEACH <br />hg a STe c <br />Network Sduumo <br />I ISI sE CMv PItWv suRE IOI <br />0 0.I. SECOND ISSUE VB <br />TE ItiORSIATI—ITNTIEDIII—SE <br />-1s Is PI—ME-181—E <br />pEPaa0.cED THE v� ae as u�i Tl OE <br />n'E�s`E'w ° SI -I <br />M = <br />0 0541823 FIRST ISSUE VB <br />NO. DATE DESCRIPTION BY <br />REVISIONS <br />`eL 'mO,,i <br />SITE NAME VEST <br />1005 <br />SITE N MBER FLFP <br />•N <br />FA NUMBER' 10032101 <br />` •`,O <br />MNS ENG. NUMBER. 43368-MMD1 <br />i <br />82M <br />SITE ADDRESS'. <br />5850 COLLEGE LANE. VERO BEACH <br />INDIAN RIVER COUNTY, FL 32966 <br />DRAWN BY: VB <br />Q•, STATE OF '�`f(/`� <br />///s1•�0�G`• <br />�1O/ <br />CHECKED BY: NDN <br />APPROVED BY: RM <br />;1I�L'^y'e <br />RAPHAEL 1. MOHAMED. PE. PEIp <br />SCALE'. N.T.S <br />SENIOR DIRECTOR OF ENGINEERING <br />TITLE SHEET <br />FL PE UCENSE NO. 82846: FL COA NO. 32141 <br />I HEREBY CERTIFY THAT THIS ENGINEERING <br />DOCUMENT WAS PREPARED BY ME OR UNDER MY <br />REV <br />DIRECT PERSONAL SUPERVISION AND THAT I AM A <br />DULY LICENSED PROFESSIONAL ENGINEER UNDER <br />�— <br />0 <br />THE LAWS OF THE STATE OF FLORIDA. <br />