Laserfiche WebLink
r <br />BOOK 99 PAGE k70 <br />Existincr Demand Total Available Positive <br />Roadway Existing Vested Segment Segment Project Concurrency <br />Segment Volume Volume Demand Capacity Demand Determination <br />3330S <br />238 <br />67 <br />305 <br />455 <br />3 Y <br />3340N <br />48 <br />39 <br />87 <br />513 <br />3 Y <br />3340S <br />44 <br />40 <br />84 <br />516 <br />3 Y <br />4830E <br />141 <br />45 <br />186 <br />694 <br />10 Y <br />483OW <br />122 <br />99 <br />221 <br />659 <br />10 Y <br />- Water <br />A retail commercial use of 150,200 square feet on the subject <br />property will have a water consumption rate of 45 Equivalent <br />Residential units (ERU), or 11,250 gallons/day. This is based upon <br />a level of service standard of 250 gallons/ERU/day. Water lines <br />extend to the site from the South County Reverse Osmosis Plant <br />which currently has a remaining capacity of approximately 2,000,000 <br />gallons/day and therefore can accommodate the potable water demand <br />associated with the proposed amendment. <br />- Wastewater <br />The subject property is serviced by the West Regional Wastewater <br />Treatment Plant. Based upon the most intense use allowed under the <br />proposed amendment, development of the property will have a <br />wastewater generation rate of approximately 45 Equivalent <br />Residential Units (ERU), or 11,250 gallons/day. This is based upon <br />the level of service standard of 250 gallons/ERU/day. The West <br />Regional Wastewater Treatment Plant currently has a remaining <br />capacity of approximately 200,000 gallons/day and can accommodate <br />the additional wastewater generated by the proposed amendment. <br />- Solid Waste <br />Solid waste service includes pick-up by private operators and <br />disposal at the county landfill. For a 150,200 square foot <br />commercial development on the subject site, solid waste generation <br />will be approximately 751 waste generation units (WGU) annually. <br />A WGU is a Waste Generation Unit measurement equivalent to one ton <br />(2,000 pounds) of solid waste. Using the accepted conversion rate <br />of one cubic yard for every 1,200 pounds of compacted solid waste <br />generated, the 150,200 square feet of commercial development would <br />be expected to generate 1,252 cubic yards of waste/year. <br />A review of the solid waste capacity for the active segment of the <br />county landfill indicates the availability of more than 850,000 <br />cubic yards. The active segment of the landfill has a 2 year <br />capacity, and the landfill has expansion capacity beyond 2010. <br />Based on staff analysis, it was determined that the county landfill <br />can accommodate the additional solid waste generated by the <br />proposed amendment. <br />- Drainage <br />All developments are reviewed for compliance with county stormwater <br />regulations which require on-site retention, preservation of <br />floodplain storage and minimum finished floor elevations. In <br />addition, development proposals must meet the discharge <br />requirements of the county Stormwater Management Ordinance. The <br />subject property is located within the M-1 Drainage Basin. Since <br />the site is located within the Indian River Farms Water Control <br />District (IRFWCD), development on the property will be prohibited <br />from discharging any runoff in excess of two inches in a twenty- <br />four hour period, which is the approved IRFWCD discharge rate. <br />In this case, the minimum floor elevation level of service standard <br />applies, since the property lies within a floodplain. Consistent <br />with Drainage Policy 1.2, "all new buildings shall have the lowest <br />habitable floor elevation no lower than six inches above the <br />elevation of the 100 -year flood elevation as shown on the Federal <br />Emergency Management Agency's Flood Insurance Rate Map, or as <br />defined in a more detailed study report." Since the subject <br />property lies within Flood Zone AE, which is a special flood hazard <br />area located within the 100 -year floodplain, any development on <br />this property must have a minimum finished floor elevation of no <br />less than 22.5 feet above mean sea level. <br />Besides the minimum elevation requirement, on-site retention and <br />discharge standards also apply to this request. With the most <br />intense use of this site, the maximum area of impervious surface <br />under the proposed zoning classification will be approximately <br />NOVEMBER 12, 1996 44 <br />