My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2025-114A
CBCC
>
Official Documents
>
2020's
>
2025
>
2025-114A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 12:52:54 PM
Creation date
6/5/2025 12:50:09 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
05/20/2025
Control Number
2025-114A
Agenda Item Number
9.O.
Entity Name
Communications International
Subject
Agreement for Upgrade to Public Safety Land Mobile Radio Network
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IX. RSL /AGC Test <br />Description <br />A TRUE COPY <br />cERTWICATION ON LAST PAGE <br />RYAN L, BUTLER, CLERK <br />The purpose of this test is to verify the RSL to AGC table correlation provided on the radio terminal <br />Factory Datasheet. A calibrated scale is provided for each RF Unit under test. The documented AGC to <br />RSL scale is serial number specific to the RF Unit under test. <br />Instructions <br />1. Log on to the Terminal under test if you have not already logged on. <br />a. Connect a PC with the EM2 software installed via the serial connector on the front of <br />the terminal labeled "COMPUTER". <br />b. Open the EM2 software and on the initial log -in screen select "Serial" from the pull <br />down and choose the appropriate "COM PORT" that the PC is using. <br />C. Enter the username: "Admin" (note this cannot be changed) enter the password. The <br />default password is "password" which can be changed). Once the correct "Admin" and <br />"User Password" is entered you will be "logged on" and the displayed terminal icons will <br />go from gray to blue to indicate communication with the terminal under test. <br />From the main display on the EM2 software view the "RSL (dBm)" value and record it on the Terminal <br />Acceptance Test form under RX Measurements "Indicated RSL" <br />2. Using a Digital Volt Meter measure the AGC voltage for the RFU under test (AGC test point is on <br />front of RFU). Record the AGC voltage in the RX Measurements "Measured AGC at RF Shelf" <br />Section of the Terminal Acceptance Test form. <br />3. Repeat this for the Far End terminal. <br />Result <br />Using the calibrated AGC to RSL scale verify the MNI GUI display is within specification. This test is <br />deemed passing when the Indicated RSL on the EM2 screen equals the measured RSL +/- 2dB. <br />Page 22 of <br />
The URL can be used to link to this page
Your browser does not support the video tag.