July 28, 1998 <br />The existing building and parking lot drainage system will require <br />revisions to comply with both Water Management Districts regard- <br />ing water quality and detention/retention areas. <br />The location of fixtures and fixture count is not suitable for an office <br />occupancy. It is our recommendation that existing toilets be de- <br />molished and that new toilet rooms be provided with the proper <br />number of fixtures, low consumption flush valves for water closets <br />and urinals, and in compliance with handicap requirements. <br />Drinking fountains/electric water coolers shall be high and low <br />configuration in compliance with A.D.A. regulations. <br />New office layouts will require that existing sprinkler heads be <br />lowered and relocated to suit new conditions. <br />New copper domestic water piping distribution overhead to toilet <br />rooms shall be provided. Provide a new underground sanitary <br />sewer collection system to connect with existing sewer mains. <br />New vents shall be provided. <br />Building/Site-Electrical/Systems <br />The electrical service is provided from three outdoor pad mounted <br />former located on the north and east sides of the building and is <br />owned/operated by the local utility. The utility service voltage for <br />the building is 480/277V 3 phase 4 wires. The building has as <br />many services as tenant spaces existed. The services grouped <br />on five (5) electrical rooms for the small tenants and two (2) large <br />main distribution boards for the anchor stores. Each of the electri- <br />cal rooms has one 400A disconnect switch and each anchor store <br />panel main is rated for 800amps. Each transformer is served by <br />separate service underground dud from the high voltage utility <br />line. The power distribution is made at 277/480 with step down <br />transformers at the local electric rooms, which feed the tenant <br />requirements. The survey was made only to the electrical rooms, <br />which served the area tenants in a radial system. The building <br />does not utilize an emergency generator. Emergency egress <br />lighting is provided by various battery back-up type sources. The <br />existing fire alarm system appears to be adequate, however <br />requires upgrade to meet latest NFPA code and ADA require- <br />ments. Existing data systems and a main data computer center <br />will have to be replaced to meet new office requirements. Tele- <br />phone service entrance cables enter the building underground <br />through two entrances: one at the anchor store at north and <br />the second at the front electrical room at north. There appears to <br />be a lot of abandoned telephone/data/security cabling and boards <br />in the building making it difficult to determine active locations. <br />Lighting and general power systems in various areas require <br />upgrading to more efficient systems. The main entries, corridors, <br />common core areas, and many of the courts remain mostly origi- <br />nal with the old lighting fixtures and device locations. <br />Replacement repairs and refurbishment to these items are re- <br />quired. Most areas utilize recessed fluorescent lighting of various <br />types and conditions. Primary load study revealed that the service <br />entrance is adequate; however, the equipment and wire must be <br />replaced. Various code violations were noted during site observa- <br />tion. Investigation for the need of emergency power system at <br />480/277 -volt, 3 phase distribution system. All services conductors <br />are aluminum. The building is missing lightning protection. Only <br />one of the anchor stores was provided with a complete lightning <br />system. Parking lot illumination appears to be deficient with large <br />obscure areas. Additional night measurements would be required <br />to assess the additional fixtures and locations necessary to meet <br />required levels. Perimeter duplex outlets outside the building shall <br />be GFI type per NEC; however, they appear to be regular recep- <br />tacles. <br />38 <br />BOOK 10W -XiW <br />