Laserfiche WebLink
BOOK j O F�1GE p) <br />- Solid Waste <br />Solid waste service includes pick-up by private operators and disposal at the county landfill. The <br />county's adopted level of service standard for landfill capacity is 1.97 cubic yards/person/year. With <br />the county's average of approximately 2.3 personsiunit, a 293 unit residential development would <br />be anticipated to house approximately 674 people (2.3 X 293). For the subject request to meet the <br />county's adopted level of service standard of 1.97 cubic yards/person/year, the landfill must have <br />enough capacity to accommodate approximately 1,328 (674 X 1.97) cubic yardsryear. <br />A review of the solid waste capacity for the active segment of the county landfill indicates the <br />availability of more than 830,000 cubic yards. The active segment of the landfill has a 1 year <br />capacity, and the landfill has expansion capacity beyond 2010. Based on the analysis, staff <br />determined that the county landfill can accommodate the additional solid waste generated by the site <br />under the proposed zoning district. <br />- Drainage <br />All developments are reviewed for compliance with county stormwater regulations which require <br />on-site retention, preservation of floodplain storage and minimum finished floor elevations. In <br />addition, development proposals must meet the discharge requirements of the county Stormwater <br />Management Ordinance. Any development on the subject property will be prohibited from <br />discharging any runoff in excess of the pre -development rate. <br />In this case, the minimum floor elevation level of service standard applies, since the property lies <br />within an AE flood zone, as designated on the Federal Emergency Management Agency's Flood <br />Insurance Rate Map. Consistent with Stormwater Management Sub -Element Policy 1.2 and section <br />930.07(2) of the county's LDRs, any new buildings constructed within an AE flood zone "must be <br />elevated a minimum of six inches above the base flood level." Since the subject property lies within <br />Flood Zone AE -9, any development on this property must have a minimum finished floor elevation <br />of no less than 9.5 feet above mean sea level. <br />Besides the minimum elevation requirement, on-site retention and discharge standards also apply <br />to this request. With the most intense use of this site, the maximum area of impervious surface under <br />the proposed zoning classifications will be approximately 1,278,050 square feet, or 29.34 acres. The <br />estimated runoff volume, based on that amount of impervious surface and the 25 year/24 hour design <br />storm, will be approximately 1,405,912 cubic feet. In order to maintain the county's adopted level <br />of service, the applicant will be required to retain approximately 344,275 cubic feet of runoff on-site. <br />With the soil characteristics of the subject property, it is estimated that the pre -development runoff <br />rate is 230.41 cubic feet/second. <br />Based upon staffs analysis, the drainage level of service standards will be met by limiting off-site <br />discharge to its pre -development rate of 230.41 cubic feet/second, requiring retention of 344.27 <br />cubic feet of runoff for the most intense use of the property, and requiring that all finished floor <br />elevations exceed 9.5 feet above mean sea level. <br />As with all development, a more detailed review will be conducted during the development approval <br />process. <br />- Recreation <br />A review of county recreation facilities and the projected demand that would result from the most <br />intense development that could occur on the property under the proposed zoning classification <br />indicates that the adopted levels of service would be maintained The table below illustrates the <br />additional park demand associated with the proposed development of the property and the existing <br />surplus acreage. <br />Park Information <br />LOS (Acres per 1,000 Population) <br />Project Demand (Acres) <br />1 <br />Surplus Acreage <br />4.0 <br />2.70 <br />838.5 <br />Based on the analysis conducted, staff has determined that all concurrency -mandated facilities, <br />including drainage, roads, solid waste, recreation, water, and wastewater, have adequate capacity to <br />accommodate the most intense use of the subject property under the proposed zoning district. <br />Therefore. the concurrency test has been satisfied for the subject request. <br />Rezoning requests are reviewed for consistency with all policies of the comprehensive plan. <br />Rezoning requests must also be consistent with the overall designation of land uses as depicted on <br />the Future Land Use Map, which includes agricultural, residential, recreational, conservation. and <br />commercial and industrial land uses and their densities. Commercial and industrial land uses are <br />located in nodes throughout the unincorporated areas of Indian River County. <br />SEPTEMBER 1. 1998 <br />