My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06/25/2015 (2)
CBCC
>
Meetings
>
2010's
>
2015
>
06/25/2015 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2018 2:35:27 PM
Creation date
8/31/2015 12:24:19 PM
Metadata
Fields
Template:
Meetings
Meeting Type
Workshop Meeting
Document Type
Agenda Packet
Meeting Date
06/25/2015
Meeting Body
Board of County Commissioners
Subject
Fire Station Locations
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
For maximum credit in the Schedule, a ladder or service company should respond on first <br /> alarms to all reported fires in buildings. It was determined the ladder or service company <br /> response is to 100%of first alarm fires in buildings. <br /> For maximum credit in the Schedule, 2 service companies are needed in your district. This <br /> need is calculated as follows: <br /> 2 service companies due to the lack of 5 or more buildings in response areas with a <br /> needed fire flow of over 3,500 gpm or 3 stories in height; or due to the method of <br /> operation. <br /> We have recognized 1.5 service companies. <br /> Tests and sample forms for recording tests for aerial ladder and elevating platforms are <br /> described in NFPA 1911, Standard for the Inspection, Maintenance, Testing and <br /> Retirement of In-service Automotive Fire Apparatus. <br /> If a ladder company is needed,the available equipment items in Table 544.A are summed to <br /> determine the points received for a Service Company, and available equipment items in <br /> Table 544.B are summed to determine the additional equipment points available for a Ladder <br /> Company. Table 544.A and 544.B points are added together to determine the total possible <br /> points available out of a possible 784 points. <br /> If a service company is needed,the available equipment items are summed in Table 544.A. If <br /> additional ground ladders are needed for the service company, the assigned points for each <br /> available ground ladder up to 4 (from Table 544.B) are added to the points determined in <br /> Table 544.A. <br /> All ladder company equipment, available service company equipment, available engine- <br /> ladder company equipment and available engine-service company equipment are summed. <br /> This sum is then divided by the sum of 784 points multiplied by the Needed Ladder(NL) plus <br /> 334 points multiplied by the Needed Service (NS) companies plus any points assigned for <br /> any additional ladders from Table 544.B. <br /> Next, this factor is multiplied by the appropriate factor (A) representing the percent of built- <br /> upon area of the city with first alarm response of a ladder, service, engine-ladder or engine- <br /> service company to fires in buildings. Finally, this product is multiplied by the 5 points <br /> available for the `Credit for Ladder Service (CLS)". The points calculated for Indian River CO <br /> FD resulted in the following: <br /> CLS =2.71 points <br /> Item 553—Credit for Reserve Ladder and Service Trucks <br /> The next item reviewed is Item 553 "Credit for Reserve Ladder and Service Trucks (CRLS)". <br /> This item considers the adequacy of ladder and service apparatus when one (or more in <br /> larger communities) of these apparatus are out of service. The number of needed reserve <br /> ladder and service trucks is 1 for each 8 needed ladder and service companies that were <br /> determined to be needed in Item 540, or any fraction thereof. When 8 or less ladder and <br /> service companies are needed, and 1 or more ladder companies are needed, the reserve <br /> truck should be a ladder truck. When the number of needed reserve ladder and service <br /> trucks exceeds the number of needed reserve ladder trucks, the difference is considered as <br /> needed reserve service trucks. <br /> ®ISO Properties,Inc.,2007 Page 21 <br /> 59 <br />
The URL can be used to link to this page
Your browser does not support the video tag.