Laserfiche WebLink
1 <br /> 1 <br /> 1 SECTION 02602 <br /> APPURTENANCES FOR GRAVITY SEWER SERVICES <br /> i <br /> 1 . SCOPE <br /> 1 This section describes the materials for appurtenances to be used in construction of gravity <br /> 1 sewerage services as shown on the Plans and specified. <br /> 2 . SEWER CONNECTIONS AT MANHOLES AND WET WELLS <br /> 1 The first joint shall be not more than 24 " from the outside of the manhole . PVC pipe must <br /> enter the manhole through a manhole coupling as manufactured by Kor-N- Seal , <br /> ' Inc . or approved equal . <br /> 3 . CLEAN OUTS <br /> 1 Clean outs shall be provided immediately prior to the service lateral end and where shown <br /> or specified . Clean out opening for pipe 8 inches or larger in diameter shall be not less <br /> 1 than 6 inches in diameter. Clean out openings for pipe less than 8 inches in diameter shall <br /> be of the same diameter as the pipe except at the ends of service laterals where they <br /> shall 4 inch in diameter as shown on the Drawings . <br /> i <br /> 1 <br /> i <br /> 1 <br /> 1 <br /> i <br /> 1 <br /> C :\Down1oad\techspec-02602.doc SC602 - 1 <br /> 1 <br />