My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-013.C
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-013.C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2016 10:05:33 AM
Creation date
9/30/2015 7:14:24 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
01/13/2004
Control Number
2004-013.C
Agenda Item Number
11.I.1
Entity Name
Barth Construction
Subject
North County Regional Park Volume II
Contract and Specifications
Area
North County Regional Park
Project Number
0399
Bid Number
6038
Archived Roll/Disk#
3209
Supplemental fields
SmeadsoftID
3589
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DIVISION 3 , CONCRETE <br /> SECTION 03010 CONCRETE <br /> A . Materials : <br /> Concrete : Transit Mix ASTM C- 94-74a <br /> 3000 P . S . I. <br /> Cement Portland ASTM C- 150-76 , Type I <br /> Aggregates : ASTM C-33 -71a <br /> Water: Potable <br /> Reinforcing : Intermediate Grade Billet ASTM A 615072 <br /> and A 305 -60 <br /> Deformation ASTM A 305 <br /> Wire Mesh : ASTM A 18642 <br /> Reinforcing Accessories : Hot-Dipped Galvanized with ASTM D- 544 <br /> B . Standards for Work : <br /> A. C . I . 318 - 89 Building Code Requirements for Reinforced Concrete <br /> A. C . I . 318 - 89 Detailing standards <br /> A. C . I . 315 -92 Specifications for structural Concrete for Buildings <br /> A . C . I . 301 -96 Recommended Practice for Concrete Form Work <br /> C . R. S . I . 347R-94 Recommended Practice for Placing reinforcing Bars <br /> C . General Requirements : <br /> 1 . No concrete shall be placed/poured without prior notice to the Owner and <br /> the Architect. All concrete is to be placed in a continuous operation. <br /> 2 . All form work shall conform to the shape and dimensions as shown on the <br /> drawings . The Contractor is to properly brace and tie water-tight the form <br /> work so as to insure dimensional stability and safety . The Contractor shall <br /> wet down the forms until permitted to do so by the Architect. Any defective <br /> concrete or concrete surfaces that are out of alignment, shall be removed <br /> and replaced . All such repair work shall be accomplished by approved <br /> concrete repair methods . <br /> 3 . Unless specified elsewhere on the drawings, all concrete shall be of a <br /> design-mix to achieve ' a comprehensive strength of 3 , 000 P . S . I . at 28 days . <br /> No retempered or contaminated concrete will be allowed. All concrete shall <br /> be placed within 90 minutes of dispatch time . <br /> 4 . Reinforcement shall be cleaned of all scale and excessive rust . All <br /> reinforcement shall be set with the standard accessories per A . C . I . 315 -74 . <br /> Minimum concrete coverage of reinforcement steel shall be as follows : <br /> 030104 <br />
The URL can be used to link to this page
Your browser does not support the video tag.