Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
01/13/2004
Control Number
2004-013.C
Agenda Item Number
11.I.1
Entity Name
Barth Construction
Subject
North County Regional Park Volume II
Contract and Specifications
Area
North County Regional Park
Project Number
0399
Bid Number
6038
Archived Roll/Disk#
3209
Supplemental fields
SmeadsoftID
3589
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 2 . Size : <br /> Manufacturer ' s standard units with nominal face dimensions of 16 " long x <br /> ' 8 " high ( 15 -5/8 " x 7-5/8 " actual) x thicknesses indicated. <br /> 3 . Type II C . M. U. , moisture controlled units . <br /> ' 4 . Hollow Loadbearing Block : ASTM C-90 and as follows : <br /> a. Weight Classification : Normal weight. <br /> 2 . 04 MORTAR AND GROUT MATERIALS <br /> A. Portland Cement: <br /> ASTM C- 150, Type I, except Type III may be used for cold weather construction. <br /> Provide natural color or white cement as required to produce required mortar color. <br /> B . Hydrated Lime : <br /> ASTM C-297, Type S . <br /> ' C . Aggregate for <br /> Mortar: <br /> ASTM C- 144 , except for joints less than 1 /4 " use aggregate graded with 100 % <br /> passing the No . 16 sieve . <br /> ' D . Aggregate for Grout : <br /> ASTM C404 . <br /> ' E. Joint Reinforcement : <br /> Provide welded-wire units prefabricated with deformed continuous side rods and <br /> plain cross rods into straight lengths of not less than 10' , with prefabricated corner <br /> ' and tee units , and complying with requirements indicated below: <br /> 1 . Width : <br /> ' Fabricate joint reinforcement in units with widths of approximately 2 " less <br /> than nominal width of walls and partitions as required to provide mortar <br /> coverage of not less than 5/8 " on joint faces exposed to exterior and %s' <br /> elsewhere . <br /> 2 . Wire Size for Side Rods : <br /> ' 9 gauge galvanized . <br /> 3 . Wire Size for Cross Rods : <br /> ' 9 gauge galvanized <br /> 4 . For single-wythe masonry provide type as follows with single pair of side <br /> rods : <br /> a. Truss design, as manufactured by Dur-o -wall, (or approved equal) , <br /> with diagonal cross rods spaced not more than 16 " o . c . Units to be 9 <br /> gauge hot dipped galvanized . <br /> 04200 -3 <br />