My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-138
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-138
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2016 2:05:06 PM
Creation date
9/30/2015 7:37:13 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
06/15/2004
Control Number
2004-138
Agenda Item Number
7.G.
Entity Name
Timothy Rose Contracting
Subject
Discharge Outlet and Rip Rap Spillway Mat
Contract and Specifications
Area
North County
Project Number
2208
Bid Number
6069
Archived Roll/Disk#
3210
Supplemental fields
SmeadsoftID
3827
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
185
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' SECTION 02610 <br /> ' RESTRAINED JOINTS, EXCAVATION AND BACKFILLING <br /> 1 . 01 RESTRAINED JOINTS <br /> A . Restrained joints shall be used on lines larger than 6-inch diameter. <br /> Sections of piping having restrained joints or those requiring restrained <br /> ' joints shall be constructed using pipe and fittings with restrained " Locked - <br /> type" joints , and the joints shall be capable of holding against withdrawal <br /> for line pressures up to 150 pounds per square inch (psi ) . The pipe <br /> fittings shall be as shown for restrained push -on joints or restrained <br /> ' mechanical oints on Page 416 in Section VI , in the Handbook of Cast <br /> Iron Pipe , 4` Edition . In all cases , restrained joints must be used per <br /> Section C below, with thrust blocks , per contract drawings . <br /> ' B . Restrained pipe joints that achieve restraint by incorporating incor oratin cutout <br /> sections installed in the bell of the pipe shall have a minimum wall <br /> thickness at the point of cutout that corresponds with the minimum <br /> specified wall thickness for the rest of the pipe . <br /> C . The minimum number of restrained joints required for resisting forces at <br /> fittings and changes in direction of pipe shall be determined from the <br /> length of restrained pipe on each side of fittings and changes in direction <br /> ' necessary to develop adequate resisting friction with the soil . Table M- <br /> 5B is provided for the Contractor as a guideline . <br /> ' L = 1 . 5PA ( 1 -COS X ) <br /> fW <br /> ' Where : L = length of pipe on each side of fittings or change in direction <br /> P = 150 psi , unless otherwise noted <br /> A = cross-sectional area In square inches based on outside diameter <br /> - (O . D . ) of pipe <br /> X = Angle of bend or change in direction in degrees <br /> f - Coefficient of friction = 1 . 4 (maximum ) <br /> W = W (earth ) + W ( pipe ) + W (water in pipe ) W (earth ) <br /> ' = (density of soil *) (depth of cover in feet) (O . D . in feet) <br /> * maximum 120 lbs/cubic ft above maximum water table elevation <br /> and 60 lbs/cubic ft below maximum water table elevation . <br /> D . Bolts and nuts for restrained joints shall be hot dipped galvanized , low <br /> ' alloy, high strength steel . <br /> E . The Contractor shall also provide restrained joints in accordance with the <br /> above criteria wherever below ground fittings on lines 12 inches in <br /> diameter or less . <br /> ' 02610- 1 <br /> F:\Utilities\UTILITY - ENGINEERING\WTP - North RO\N RO Brine Line Discharge - UCP#2208\BID DOCUMENTS North <br /> ' County RO\BID DOCUMENTS\02610 Restrained Joints , Excavation , and Backfilling .doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.