Laserfiche WebLink
Attachment " C " <br /> BARTH <br /> Construction, Inc. <br /> General Contractor CGCO07847 <br /> July 7 , 2005 <br /> Battalion Chief Ed Prime <br /> Indian River County Fire Department <br /> 1500 Old Dixie Hwy <br /> Vero Beach , Florida 32960 <br /> Re : Indian River County Fire Station #6 <br /> Chief Prime, <br /> The following is the scope of work you requested to be performed at Indian River County Fire Station <br /> # 6 . <br /> Building Exterior <br /> Replace roof shingles on entire building, install continuous cleat drip edge <br /> Remove existing siding on high gable end over lower roof <br /> Repair any damaged, rotten wood and repair flashing behind this high gable end <br /> Replace siding on high gable end with Hardi Plank siding or equivalent <br /> Remove all existing exterior siding below the soffits, install stucco over existing block walls <br /> Remove existing siding on the large East and West gable ends, replace with Hardi Plank siding or <br /> similar. Includes any framing necessary to install new siding <br /> Repair any damaged, rotten wood and flashings behind existing siding <br /> Repair any damaged or rotten soffit and fascia boards and framing <br /> Replace soffit vent screen material with a vinyl soffit vent material (Vinyl Corp . or similar) <br /> Remove all four raised planters that are against the exterior walls, install new stucco in these areas . <br /> Pressure clean and paint exterior of building, including garage bays (all materials and equipment stored <br /> in bay will need to be removed during this process) . <br /> Install two wind loaded 12 ' x 12 ' motorized roll up garage doors <br /> Replace all light fixtures inside the garage bays <br /> Close up the large gable end vents on the East and West side of the building . <br /> Repair any damaged landscape/ irrigation caused by this project <br /> Install hurricane accordion shutters (new) at all windows <br /> Building Interior <br /> Remove all existing ceiling grid, tile and above ceiling insulation through out building <br /> Install new craft back R- 19 insulation at the bottom cord of existing trusses . <br /> Install an air barrier through out building consisting of one layer of 5 /8" Type X gypsum board to under <br /> side of existing trusses <br /> Install new standard grid and 2 ' x 4 ' flat lay-in ceiling the through out building . <br /> Vinyl coated gypsum ceiling tile installed in the restrooms and kitchen areas <br /> 1717 Indian River Boulevard * Suite 202A * Vero Beach , Florida 32960 <br /> Phone : (772) 778 -3072 * Fax : (772) 770-3017 <br /> E-mail : in.fo�,:.u,Ibarthconstructicm . com * Internet: wti�� w . .......................................................... <br /> \\Ntsbs\barth\Projects\IRC Fire Stations\STATION #6\Correspondence\Owner\Attachment C 7 . 7 . 05 . doc <br />