Laserfiche WebLink
PART 3 -- EXECUTION <br />3.01 GENERAL CONSTRUCTION METHODS <br />Seeding and mulching operations will not be permitted when wind velocities <br />exceed 15 miles per hour. Seed shall be sown only when the soil is moist and in <br />proper condition to induce growth. No seeding shall be done when the ground is <br />frozen, unduly wet, or otherwise not in a tillable condition. Whenever a suitable <br />length of right-of-way or adjacent area has been graded, it shall be made ready, <br />when directed by the Engineer, and grassed in accordance with these <br />specifications. Grassing shall be incorporated into the project at the earliest <br />practical time in the lift of the contract. <br />3.02 SODDING <br />A. Preparation of Area to be Sodded: The ground which is to receive sod <br />shall have been graded to proper elevations (2" below sodded grade) to <br />match pre -construction conditions or proposed grades. All disturbed <br />swales and ditches shall have been restored to their pre -construction <br />condition or better. The pre -construction grade shall be maintained and <br />the prepared soil shall be loose and reasonable smooth. It shall be <br />reasonable free of large clods, roots, patches of existing grass, and other <br />material which will interfere with the sod -laying operations or subsequent <br />mowing and maintenance operations. <br />B. Laying of Sod: Sod shall be installed in all areas so designated by <br />Engineer. Sod shall be carefully placed so that each piece abuts flush to <br />all surrounding sod, regardless of whether surrounding sod is new or <br />existing. Where new sod is to be placed adjacent to existing sod, the new <br />sod must be cut in to match the elevation of the existing sod. Uneven sod <br />which might cause mowing problems will be rejected. New sod laid on <br />top of existing sod will also be rejected. All sod placed on steep slopes <br />(greater than 1:1) shall be pinned with a wooden pin to keep it in place. <br />C. Rolling: Immediately after completion of the sod laying, the entire sodded <br />area shall be rolled thoroughly with the equipment specified. At least two <br />trips over the entire area will be required. <br />D. Watering: Newly -sodded areas are to be watered by Contractor as <br />necessary to keep sod alive until the Contractor is closed out. Dead sod <br />shall be replaced by Contractor prior to contract closeout. <br />3.03 SEEDING <br />A. Sequence of Operations: The operations involved in the work shall <br />proceed in the following sequence: preparation of the ground, seeding, <br />spreading, and cutting in mulch. <br />02485 Grassing.doc <br />02485-3 <br />K:Q5-125 IRC 741h Ave Force Main-ARCHNEI&dding Contract SpecificationsZ24& Grassing.doc <br />