2007-012A
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-012A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2016 12:10:01 PM
Creation date
9/30/2015 10:29:55 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
01/09/2007
Control Number
2007-012A
Agenda Item Number
11.1.2
Entity Name
L.H. Tanner
Subject
Contract/Specifications Indian River Drive South Sidewalks
Area
Indian River Drive
Project Number
0201
Bid Number
2007027
Supplemental fields
SmeadsoftID
6066
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. <br /> Chapter 4 - Best Management Practices for Erosion and Sediment Control <br /> Prefabricated drop inlet external filter (Suntree Isles Grate Inlet Protector) <br /> 1 . Place the device over the inlet. If the inlet has a grate , the device shall be secured <br /> to the grate by means of a long toggle bolt. If the grate is not present, the device <br /> shall be bolted directly to the concrete . <br />' 2 . Sediments shall be removed when they have accumulated to within one foot (30 <br /> cm) of the top of the device . The filter fabric elements shall be cleaned or replaced <br /> at that time. <br /> NOTE: This segment does not constitute a product endorsement. <br />' Gravel curb inlet sediment filter <br /> 1 . Hardware cloth or comparable wire mesh with 1 /2 inch (13 mm) openings shall be <br /> placed over the curb inlet opening so that at least 12 inches (30 cm) of wire extends <br /> across the top of the inlet cover and at least 12 inches (30 cm) of wire extends <br /> across the concrete gutter from the inlet opening. (See Plate 4. 08k) <br /> 2 . Stone shall be piled against the wire so as to anchor it against the gutter and inlet <br /> cover and to cover the inlet opening completely. MOT No . 1 Coarse Aggregate <br /> shall be used . <br /> 3 . An overflow weir can be constructed of 2" x4" (5 x 10 cm) boards to lessen ponding <br /> from this practice . (See Plate 4 .08L) <br /> 4 . If the stone filter becomes clogged with sediment so that it no longer adequately <br /> r performs its function , the stone must be pulled away from the block, cleaned and <br /> replaced . <br /> Block and gravel curb inlet sediment filter <br /> 1 . Two concrete blocks shall be placed on their sides abutting the curb at either side <br />.. of the inlet opening . <br /> 2 . A 2" x 4" (5 x 10 cm) board shall be cut and placed through the outer holes of each <br /> r spacer block to help keep the front blocks in place . <br /> 3 . Concrete blocks shall be placed on their sides across the front of the inlet and <br /> r abutting the spacer blocks . (See Plate 4.08m) <br /> 4 . Wire mesh shall be placed over the outside vertical face (webbing) of the concrete <br /> r blocks to prevent stone from being washed through the holes in the blocks. <br /> Hardware cloth with 112 inch (13 mm) openings shall be used . <br /> 5 . FDOT No . 1 Coarse Aggregate shall be piled against the wire to the top of the <br /> barrier. <br /> r 4-45 <br /> r <br />