Laserfiche WebLink
s. <br /> Item # 1 : LIGHTING CONTROL SENSORS : Note for clarification- There are no motion <br /> sensors indicated for lighting control because 2004 FBC Section 13 -415 . 1 . ABC. 1 . I <br /> does not require lighting control systems for interior spaces in buildings of less than <br /> 5000 square feet. All three buildings are less than 5 ,000 square feet each. Exterior <br /> lighting control is provided by an electro-mechanical timer. <br /> Item #2 : ALUMINUM WINDOWS : Specifications Section 08520- Section 1 .02 , (A) : An <br /> approved, or equal , manufacturer is Sol-A-Trol Aluminum Products, Miami, FL, Ph : <br /> 305-681 -2020. <br /> Item #3 : INTERCOM SYSTEM : All references to an intercom system shall be deleted. There <br /> will be no intercom system in any of the buildings. <br /> Item #4 : CHALKBOARDS, MARKERBOARDS AND TACKBOARDS : Specifications <br /> Section 10100- An acceptable, or equal , manufacturer is American Visual Display <br /> Products, LLC. Theresa Cahill representative at tcahilKi>acs- win .com . Phone : 334- <br /> 514-4524 . <br /> Item45: ALUMINUM WALKWAY COVERS : Specifications Section 10531 - An acceptable, <br /> or equal , manufacturer is American Walkway Covers , LLC . Note : the following is <br /> additional information on structural loading ( See also Addendum #2 , item <br /> #23 ). Walkway covers shall meet the following Structural criteria : a. 135 mph wind, ( 3 <br /> second gusts), ( 1 .0 importance factor), <br /> b . Exposure B, ( open structure), c. Use factor 1 .0, d . Meet Section 1609, FBC 2004 <br /> w/ 2007 amendments , and e. Meet ASCE 7-02 . <br /> Item #6 : WALL INSULATION : Architectural Sheets, Sections B/A- 10 and C/A- 10 call out R- <br /> 19 vinyl-faced fiberglass wall insulation. Installation of the R- 19 insulation shall be <br /> let-in between the wall gins, in lieu of compressing the insulation between the <br /> vertical panel back and the wall girts. Utilize adhesive mounted pin mounts, or a <br /> similar approved mounting system, to secure the insulation to the flat back section of <br /> the 12" wide X 1 %" deep flush face mounted wall panels. (See Item # 12 of this <br /> Addendum for wall panel description) . Center to center of pins as required to insure a <br /> unifomi and secure installation of the batt insulation . Trim any protruding ends on <br /> installed pins to prevent injury. <br /> Item #7: MAIN DISCONNECT AT ADMINISTRATION BUILDING : Sheet E-6 calls for an <br /> 800 amp utility meter. Note : the main disconnect shall be revised downward to 600 <br /> amp. The 600 amp meter sockets and Class 480 meters are commercially available. <br /> Item #8 : ELECTRICAL SERVICE: Note, the electrical service shall remain single phase as <br /> designed. <br /> Item #9 : FI - FOIL PRODUCT : Building Section A/A- 10 : the Fi-Foil product called out at the <br /> ceiling assembly shall be model "Radiant Shield NT' or the equivalent Fi -Foil <br /> product simply called "Radiant Shield" . This is a perforated product with vapor <br /> Page I <br /> F:\Engineering\Capital Projecls.0701 IRC PARKS COMPLX\Addendums\IRC Parks Maintenance Complex Addendum #4.doc <br />