My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-192
CBCC
>
Official Documents
>
2000's
>
2009
>
2009-192
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 11:41:36 AM
Creation date
9/30/2015 11:37:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
07/14/2009
Control Number
2009-192
Agenda Item Number
8.I.
Entity Name
DeAngelis Diamond Construction
Subject
Contract IRC Parks Maintenance Complex
Area
5500 77th St.
Project Number
0701
Bid Number
2009043
Supplemental fields
SmeadsoftID
6815
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item #10: Draftstopping at Administration Building: Is located on Sheet LS- 1 per wall rating legend as a <br /> "Long dash, dot, long dash". Draftstopping material is '/x" drywall applied to 3 5/8", 25 gauge <br /> steel studs at 24" o/c extended from top of wall partitions to underside of deck. Wall shall be <br /> taped and mudded. <br /> Item #11 : Door Schedule Sheet A-4 : Doors #6 & #7 require 45 minute rating on doors and frames to <br /> comply with Life Safety requirements . Specifications section 08710, headings #6 and #5 are <br /> correct. <br /> Item #12 : Air Compressor: (Note for Clarification) : 220V, 5 horse power, 175psi , vertical tank, unit is to <br /> be located in the mechanic bay per Sheet A-2. Sheets E-4 & E-7 denote the power circuit and <br /> panel MB- 12 : 14. Sheet P-3 denotes airline piping routing and condensate thru-wall drain <br /> location. Sheet P-4 denotes air-line piping routing and the isometric drawing of a typical air <br /> drop . <br /> Item #13 : Sheet A- 14 (Note for Clarification): Elevations A/A- 14 and B/A- 14 are "Women" not men and <br /> elevation C/A- 14 is men, not women. <br /> Item #14: Bath Accessories (Note for Clarification) : All fixed mirrors shall be 18" x 30" per specification <br /> section 10800, (2 .08)(A) in lieu of sizes depicted on drawings . Add one additional mirror over <br /> the "Men' s" sink in Administration Building. Toilet room elevation B/A- 1 on sheet A- 1 is <br /> incorrect at the dimension of the toilet paper dispenser. The 36" dimension is to the far edge of <br /> the dispenser, NOT to the centerline. Sheet ACC is correct, and this is a maximum dimension. <br /> Provide a single heavy duty clothes hook in the men and women shower rooms on the frame <br /> wall that separates the two rooms. Hook as specified with backing in specification section <br /> 10800, 2 .09, and mounted at 48" max A.F.F . for accessibility compliance. Provide a shelf with <br /> mop and broom holder in Mechanical Room #2 above the mop sink S-3 . Unit per specification <br /> section 10800, 2 . 10. No diaper changing stations are required for this project. <br /> Item #15 : Women ' s Shower Room Shower: Shall be the same wall and pan detail as 2/A- 14. Cultured <br /> marble wall panels to 8 ' -0" height. <br /> Item #16: Threshold Building: None of the three buildings in this complex requires Threshold Inspection <br /> Services. Criteria for this requirement are a) greater than 3 stories in height, b) greater than 50 ' <br /> in height, c) assembly occupancy classification over 5 ,000 square feet and 500 people. <br /> Item #17: Metal Roofing Clarification: The metal roofing on all three (3) buildings shall be Englert (or <br /> approved equal) Series S2500 Roofing, with 2" mechanically seamed, 180 degree seam, 24 <br /> gauge roofing with optional ribs, and 16" centers on seams. Englert Series 52500 meets UL and <br /> ASTM standards for structural roofing when applied directly over purlins. Refer to <br /> Specifications Section 07610 for acceptable manufacturers. Roofing assembly shall meet all <br /> requirements of the FBC 2004 for hurricane wind resistance in a coastal zone at 135 mph. <br /> (Note: This project is permitted under FBC 2004 with 2005 amendments, and interpolated wind <br /> speed of 135 mph) . Refer to sheet S- 1 for complete information. All clips, closures, and <br /> fasteners shall be as recommended by the manufacturer of the roofing assembly. Local Englert <br /> rep is Tom Blowers at 813-446-5303 . <br /> - 3 — <br /> F:IEngineeringlCapital Projects10701 IRC PARKS COMPLEXIAddendumsJACParks Maintenance Complex Addendum #2. doe <br />
The URL can be used to link to this page
Your browser does not support the video tag.