Laserfiche WebLink
Itent #18: Specification Section 13122 : Metal Building System Article 2 .02 (C)(D) Delete the statement <br /> "All roof panels must meet FBC 2003 required impact ratings". Also at 2 .02(D) wall panels <br /> shall be 24 gauge. <br /> Article 2 .04, (A) 1 , 2, 3 — delete in its entirety. <br /> Article 2.04, (B) 1 & 2 — delete in its entirety. <br /> Article 2. 04 Panel Length (change to "C" in lieu of `B ") and item 1 to remain. <br /> Article 2 . 06 (A) & (B) to be deleted in their entirety. <br /> Item #19 : Painting of Steel Building Components : Specification 09900 requires field painting of the metal <br /> building system main columns, beams, base plates and through bolts overlaying the <br /> manufacturer' s shop primer. This will apply in the Maintenance and Storage Buildings only <br /> and does not apply to wall girts or roof purlins. <br /> Item #20: Metal Siding & Soffit Panels: Located on the Maintenance and Storage Buildings shall be <br /> Englert Model A4000, 12" W x 1 '/z" H, 24 gauge, with optional ribs. This is a flush panel to be <br /> used on the walls, soffits at overhangs and ceiling of break area. This panel has concealed <br /> fasteners. Utilize a Kynar 500 coated galvalume panel, color EM-330 Everglade Moss. <br /> Item #21 : Exterior Building Colors : Change color �Rto Sherwin Williams "Dovetail" (SW 7018), in <br /> lieu of Dorian Gray (SW 7017). Paint 18" H x 7 ' -8 " stucco panel behind the Administration <br /> Building house numbers 6) inlieu of` . <br /> Item #22 : Operable Aluminum Shutters : Style to be "Tongue and Groove" as manufactured by "Florida <br /> Shutters", Ph. (772) 569-2200. Toll free (800) 741 -2202 . Color — powder coated RAL 6013 , to <br /> match roofing color. <br /> Item #23 : Aluminum Walkway Covers: Revise Specifications Section 10531 , 1 .03 (B) to read " 135 mph <br /> wind", in lieu of 100 mph wind. Color of walkways to match Sherwin Williams paint: <br /> Alabaster (SW 7008), using a baked enamel or ESP coating system. <br /> Item #24: Roof Slopes at Maintenance & Storage Buildings: Shall be I " in 12" in lieu of 1 '/2" in 12" as <br /> denoted on Sections A/A-2, A/A-3 , & Elevations on Sheet A-8 . Roof slope at Administration <br /> Building is 4" in 12" per plans and sections . <br /> Item #25: Gutters and Downspouts: Color of gutters and downspouts to be manufacturer's standard ESP <br /> white in lieu of color specified in Spec Section 07710, 1 . 01 , (B). <br /> Item #26 : Specifications Section 16715 Voice and Data Cabling: A new revised and renumbered Section <br /> 16750 has been provided with this Addendum. The Table of Contents has been modified to add <br /> this section. All Voice and Data Cabling shall be by the General Contractor as located on the <br /> plans. The final "crossover" from the Phone Company lines to the Owner supplied private <br /> telephone equipment system shall be provided by the Owner. <br /> Item #27: Specification Section 10440 — Specialty Signs : Under "Administration Building" the aluminum <br /> house numbers shall be "5500" (in lieu of the incorrect address of 5450 depicted on Sheet A-5). <br /> Provide 8" high numbers in lieu of 12" high numbers. Numbers supplied by Metallic Arts or <br /> - 4 — <br /> F. lEngineeringICapitalProjects10701 IRC PARKS COMPLEXIAddendumsLrRC Parks Maintenance Complex Addendum #1.doe <br />