My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-192
CBCC
>
Official Documents
>
2000's
>
2009
>
2009-192
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 11:41:36 AM
Creation date
9/30/2015 11:37:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
07/14/2009
Control Number
2009-192
Agenda Item Number
8.I.
Entity Name
DeAngelis Diamond Construction
Subject
Contract IRC Parks Maintenance Complex
Area
5500 77th St.
Project Number
0701
Bid Number
2009043
Supplemental fields
SmeadsoftID
6815
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORT PIERCE ENGINEERING, INC. IRC Maintenance <br /> 4.6 Unless suitably protected against dust, paint, etc. , spot type smoke detectors shall not be installed <br /> until the final construction clean-up has been completed. In the event of contamination during <br /> construction, the detectors must be replaced. <br /> CAUTION: Covers supplied with smoke detector heads do not provide protection against heavy <br /> construction dust, spray painting, etc., and must not be used for that purpose. They are suitable <br /> only during final, minor cleanup or touchup operations. <br /> 4. 7 A detector installed where accidental damage or deliberate abuse is expected shall be provided <br /> with a guard that is listed for use with it and is acceptable to the AHJ. <br /> 4.8 Identification of individual detectors is not required, but each detector location shall be shown on <br /> the fire alarm construction plan and as-built drawing. <br /> 4.9 All air duct/plenum detectors must have a Remote Alarm Indicator Lamp (RAIL) installed in the <br /> nearest corridor or public area and identified by an engraved label affixed to the wall or ceiling. <br /> Duct smoke detectors are permitted to be installed only inside an air duct. It is not appropriate to <br /> mount them in front of a return air opening. Duct detectors shall also be installed in a manner <br /> that provides suitable, convenient access for required periodic cleaning and calibration (see 4. 11 ) . <br /> 4. 10 Duct detector sampling tubes shall extend the full width of the duct and shall extend through the <br /> far side of the duct. An appropriate and durable air-tight seal shall be made around the tube <br /> where it penetrates the duct wall. The end of the tube shall be plugged with a rubber stopper. <br /> This facilitates visual inspection, intake tube cleaning, and injection of smoke or equivalent <br /> aerosol for testing the detector. <br /> 4. 11 Each duct detector installation shall be accessible for sampling tube inspection and cleaning. <br /> Indicate airflow direction on the duct, adjacent to the detector, using stencil or permanent decal . <br /> 4. 12 Install smoke detectors in interior exit access corridors, M/E rooms, computer rooms, <br /> unsprinklered storage rooms, and customarily unoccupied rooms or spaces containing flammable <br /> materials. <br /> 5.0 Reserved. <br /> 6.0 System Conflguration and Installation <br /> 6. 1 Reserved. <br /> 6. 2 Reserved. <br /> 6.3 All fire alarm system wiring shall be in '/, inch or larger diameter metal conduit, surface metal <br /> raceway, or (in finished areas only, for improved appearance) surface non-metallic raceway. <br /> PVC conduit is permitted to be used underground, in concrete, and in locations subject to severe <br /> corrosion. <br /> 6 .4 All conduits that penetrate outside walls from air conditioned space must have internal sealing <br /> 16965 FIRE DETECTION & ALARM SYSTEM Page 6 OF 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.