FORT PIERCE ENGINEERING, INC. IRC Maintenance <br /> 4.6 Unless suitably protected against dust, paint, etc. , spot type smoke detectors shall not be installed <br /> until the final construction clean-up has been completed. In the event of contamination during <br /> construction, the detectors must be replaced. <br /> CAUTION: Covers supplied with smoke detector heads do not provide protection against heavy <br /> construction dust, spray painting, etc., and must not be used for that purpose. They are suitable <br /> only during final, minor cleanup or touchup operations. <br /> 4. 7 A detector installed where accidental damage or deliberate abuse is expected shall be provided <br /> with a guard that is listed for use with it and is acceptable to the AHJ. <br /> 4.8 Identification of individual detectors is not required, but each detector location shall be shown on <br /> the fire alarm construction plan and as-built drawing. <br /> 4.9 All air duct/plenum detectors must have a Remote Alarm Indicator Lamp (RAIL) installed in the <br /> nearest corridor or public area and identified by an engraved label affixed to the wall or ceiling. <br /> Duct smoke detectors are permitted to be installed only inside an air duct. It is not appropriate to <br /> mount them in front of a return air opening. Duct detectors shall also be installed in a manner <br /> that provides suitable, convenient access for required periodic cleaning and calibration (see 4. 11 ) . <br /> 4. 10 Duct detector sampling tubes shall extend the full width of the duct and shall extend through the <br /> far side of the duct. An appropriate and durable air-tight seal shall be made around the tube <br /> where it penetrates the duct wall. The end of the tube shall be plugged with a rubber stopper. <br /> This facilitates visual inspection, intake tube cleaning, and injection of smoke or equivalent <br /> aerosol for testing the detector. <br /> 4. 11 Each duct detector installation shall be accessible for sampling tube inspection and cleaning. <br /> Indicate airflow direction on the duct, adjacent to the detector, using stencil or permanent decal . <br /> 4. 12 Install smoke detectors in interior exit access corridors, M/E rooms, computer rooms, <br /> unsprinklered storage rooms, and customarily unoccupied rooms or spaces containing flammable <br /> materials. <br /> 5.0 Reserved. <br /> 6.0 System Conflguration and Installation <br /> 6. 1 Reserved. <br /> 6. 2 Reserved. <br /> 6.3 All fire alarm system wiring shall be in '/, inch or larger diameter metal conduit, surface metal <br /> raceway, or (in finished areas only, for improved appearance) surface non-metallic raceway. <br /> PVC conduit is permitted to be used underground, in concrete, and in locations subject to severe <br /> corrosion. <br /> 6 .4 All conduits that penetrate outside walls from air conditioned space must have internal sealing <br /> 16965 FIRE DETECTION & ALARM SYSTEM Page 6 OF 10 <br />