Laserfiche WebLink
f � <br /> 7. Before FPL can begin its engineering work on the underground electric distribution facilities, the Customer shall provide FPL with the <br /> following : <br /> a) Paving , grading , and drainage plans showing all surface and sub-surface drainage satisfactory to FPL, <br /> b) A construction schedule, <br /> c) An estimate of when electric service will be required , and Copies of the customer's final construction plans as <br /> well as other construction <br /> drawings (plot, site, sewage, electrical , etc. ) requested by FPL plats provided by the customer must be either recorded by thre <br /> circuit clerk or <br /> other recording officer or prepared and certified as meeting the requirements for recording (except approval by the <br /> governing body) by a <br /> registered land surveyor <br /> d) Copies of the Customers final construction plans as well as other construction drawings (plot, site, sewage , electrical , etc. <br />) requested by FPL <br /> provided by the customer must be either recorded by the circuit clerk or other recording officer or prepared and certified <br /> as meeting the <br /> requirements for recording (except approval by the governing body) by a registered land surveyor. <br /> 8. Prior to FPL construction pursuant to this agreement, the Customer shall : <br /> a) Clear the FPL easement on the Customer's property of tree stumps, all trees , and other obstructions that conflict with construction , <br /> including the <br /> drainage of all flooded areas. The Customer shall be responsible for clearing , compacting , boulder and large rock removal <br />, stump removal , <br /> paving and addressing other special conditions. The easement shall be graded to within six inches of final grade with soil stabilized. <br /> b) Provide property line and corner stakes, designated by a licensed surveyor, to establish a reference for locating the underground <br /> cable trench <br /> route in the easement and additional reference points when required by FPL. Also, the Customer shall provide stakes identifying <br /> the location , <br /> depth , size and type facility of all non-FPL underground facilities within or near the easement where FPL distribution facilities <br /> will be installed . <br /> The Customer shall maintain these stakes , and if any of these stakes are lost, destroyed or moved and FPL requires their use, <br /> the Customer <br /> shall replace the stakes at no cost to FPL, unless the stakes are lost, destroyed or moved by an agent, employee, contractor or subcontractor <br /> of <br /> FPL, in which case FPL will pay the Customer the cost of replacing the stakes. <br /> c) It is further understood and agreed that subsequent relocation or repair of the FPL system , once installed , will be paid by <br /> the Customer if said <br /> relocation or repair is a result of a change in the grading by the Customer or any of the Customer's contractors or subcontractors <br />from the time <br /> the underground facilities were installed ; and , that subsequent repair to FPL's system , once installed , will be paid by the Customer if <br /> said repair is <br /> a result of damage caused by the Customer or any of the Customer's contractors or subcontractors . <br /> d) Provide sufficient and timely advance notice ( days) as required by FPL, for FPL to install its underground distribution <br /> facilities prior to the <br /> installation of paving , landscaping, sodding, sprinkler systems, or other surface obstructions. In the absence of sufficient <br />coordination , as <br /> determined by FPL, by the Customer, all additional costs for trenching and backfilling shall be paid by the Customer, and none <br />of the costs of <br /> restoring paving , landscaping , grass , sprinkler systems and all other surface obstructions to their original condition , should they be <br /> installed prior <br /> to FPL's facilities , shall be borne by FPL. <br /> e) Pay for all additional costs incurred by FPL which may include, but are not limited to, engineering design , administration and relocation <br /> expenses, <br /> due to changes made subsequent to this agreement on the subdivision or development layout or grade . <br /> f) Provide applicable trenching , backfilling and installation of Company provided conduit in accordance with FPL specifications. <br /> 9. FPL shall : <br /> a ) Provide the Customer with a plan showing the location of all FPL underground facilities , point of delivery, and <br /> transformer locations and <br /> specifications required by FPL and to be adhered to by the Customer. <br /> b) Install , own , and maintain the electric distribution facilities up to the designated point of delivery except when otherwise noted . <br /> c) Request the Customer to participate in a pre-construction conference with the Customer's contractors , the FPL representatives and other utilities <br /> within six (6) weeks of the start of construction . At the pre-construction conference , FPL shall provide the Customer with an estimate <br /> of the date <br /> when service may be provided . <br /> 10. This Agreement is subject to FPL's Electric Tariff, including but not limited to the General Rules and Regulations for Electric Service <br /> and the Rules of <br /> the Florida Public Service Commission , as they are now written , or as they may be revised , amended or supplemented . <br /> The Customer and FPL will coordinate closely in fulfilling obligations in order to avoid delays in providing permanent electric <br /> service at the time of the <br /> Customer's receipt of a certificate of occupancy. <br /> Accepted : Ac ed : <br /> - 22 - 03 <br /> For FPL (Date) sto er (Date) <br /> V6AIMIJ �9GA�U 7Date) 3 <br /> (PrintName) Witness (Date) <br /> 7 - 22 - 03 <br /> Witness (Date) <br /> AP ROVED : <br /> CiAiNim) <br /> t UF <br /> BY <br /> FE <br /> ASNTY ATTORNEY <br />