Laserfiche WebLink
SECTION 01541 <br /> PROTECTION OF THE WORK AND PROPERTY <br /> .. damage to them and to prevent interruption of the services which such <br /> structures provide . If CONTRACTOR damages an underground structure , <br /> restore it to original condition at CONTRACTOR's expense . <br /> 7. Necessary changes in the location of the Work may be made by <br /> ENGINEER , to avoid unanticipated underground structures . <br /> 8 . If permanent relocation of an underground structure or other subsurface <br /> facility is required and is not otherwise provided for in the Contract <br /> Documents , ENGINEER will direct CONTRACTOR in writing to perform the <br /> Work, which shall be paid for under the provisions of Article 11 of the <br /> • General Conditions . <br /> B . Surface Structures: <br /> 1 . Surface structures are defined as structures or facilities above the ground <br /> surface . Included with such structures are their foundations and any <br /> extension below the surface . Surface structures include, but are not limited <br /> to , buildings , tanks, walls , bridges , roads , dams , channels , open drainage , <br /> piping , poles , wires , posts, signs , markers , curbs , walks and all other facil- <br /> ities that are visible above the ground surface. <br /> i <br /> C . Protection of Underground and Surface Structures : <br /> 1 . Sustain in their places and protect from direct or indirect injury, all <br /> underground and surface structures located within or adjacent to the limits <br /> of the Work. Such sustaining and supporting shall be done carefully, and as <br /> required by the party owning or controlling such structure . Before <br /> proceeding with the work of sustaining and supporting such structure , satisfy <br /> the ENGINEER that the methods and procedures to be used have been <br /> AV approved by the party owning same . <br /> 2 . Assume all risks attending the presence or proximity of all underground and - <br /> surface structures within or adjacent to the limits of the Work. <br /> CONTRACTOR shall be responsible for all damage and expense for direct <br /> or indirect injury caused by its Work to any structure. CONTRACTOR shall <br /> repair immediately all damage caused by his work, to the satisfaction of the <br /> W, OWNER of the damaged structure. <br /> D . All other existing surface facilities , including but not limited to , guard rails , posts , <br /> guard cables, signs , poles , markers , and curbs which are temporarily removed to <br /> facilitate installation of the Work shall be replaced and restored to their original <br /> condition at CONTRACTOR'S expense. <br /> r <br /> • 1 . 6 DAMAGE TO EXISTING STRUCTURES AND UTILITIES <br /> 01541 -4 F\Engineering\Capital Projects\9611-CR 512 Widening\9611 <br /> CR 512 PHASE MContract Documents\01541 - Protection of Property.doc <br />