Laserfiche WebLink
QUESTIONS, CLARIFICATIONS, CORRECTIONS AND CHANGES <br /> Question: Bid Item 1050- 11 -224D Directional Drill for 16" Water main — Plans do not indicate any <br /> directional drilling; please clarify where the directional drilling is to be performed. <br /> Answer: Directional drill is optional . All work will be open cut. H.T.P . may be used at conflict <br /> points . <br /> Question: Plan Sheet 14 of the 66 h Avenue Set (Arcadis set) indicates mast arms and junction boxes to <br /> be removed but no new mast arms or signals . Please clarify what is to be done here. <br /> Answer: New mast arms and other signal equipment at SR60/66th Avenue will be installed by others. <br /> Question: Plan Sheets 15 and 37 of the 16th Street Set (IRC set) indicates work to be performed at the <br /> 74th Street/ 16th Street intersection, but there are no items or quantities in the Summary of <br /> Quantities or Bid Form to reflect what is to be done . Please clarify what is to be done at this <br /> intersection. <br /> Answer: Asphalt overlay, base work and pavement markings are included in line item quantities. <br /> Question: Bid Item 120-4 Excavation, Subsoil (Lake) . FDOT Spec 120-4 Subsoil excavation is for the <br /> removal of unsuitable materials. Spec 120-4. 1 is for the removal of muck, rock, clay or <br /> other unsuitable material. Is this the correct description of this bid item, or should it be for <br /> the lake excavation on 66`h Avenue? <br /> Answer: Line Item 120-4 Excavation, Sub-soil (LAKE) (Includes Stockpile & Restoration) shall <br /> include disposal of unsuitable material, stockpiling of suitable material and restoration of <br /> stockpile. <br /> Question: There are bid items for 12" and 16" joint restraints (Bid Items 1080- I1 -49A and 1080- 11 - <br /> 49) but no bid items for 6" and 8" joint restraints. <br /> Answer: Restraint joints for 6" and 8" pipe shall be included in the pipe cost. <br /> -- - . . - - Question :... _ _. Plans for- 66`11 Ave . _(IRC set) and- 66`h Ave... (Arcadis-set).indicate existing soil to-be removed <br /> within 3 ' below the proposed subgrade . However, there is no provision for this requirement <br /> on the 16"' Street Plans (Carter set) . Please clarify. <br /> Answer: The removal and material 3 ' below the proposed sub-grade is indicated on Sheets 8 & 9 on <br /> the Carter Associates, Inc. set of plans. <br /> Page 2 of 4 <br /> F:IEngineeringl Capita( ProjecW9920-16111 St, 74th Ave to 66th AM9920 Contract Documents & Spec" ddendum 43.doc <br />