HomeMy WebLinkAbout2007-188 (? '�a 0 ?
Page I o( 2
Board of County Commissioners Zov �- ( gg
1810 25th Street
Vero Beach, Florida 32960
Telephone : (772) 567-8000 FAX: (772)-778-9391
SUBSURFACE SOIL EXPLORATION
AND GEOTECHNICAL ENGINEERING EVALUATION
for
8th Street from 66th Avenue to 74th Avenue and 74th Avenue from 4th Street to 12th
Street, IRC Project #03107
WORK ORDER NO . 5 ( Engineering Division)
FOR
FOR PROFESSIONAL GEOTECHNICAL SERVICES AGREEMENT
FOR ANNUAL GEOTECHNICAL SERVICES CONTRACT NO . 0534
WITH
ARDAMAN & ASSOCIATES , INC .
All services performed under this contract shall be supervised and certified by a licensed
Professional Engineer (PE) registered with the State of Florida and staff employed directly with
your firm .
Scope of Services
All work shall be performed on a unit price basis in accordance with the attached Scope of
Services dated June 1 , 2007 and shall comply with Standards enumerated in the RENEWAL OF
THE ANNUAL GEOTECHNICAL SERVICES CONTRACT, IRC PROJECT NO . 0534 WITH
ARDAMAN & ASSOCIATES , INC . Effective Date: October 1 , 2006 .
Minimum Specification Requirements as follows :
• Auger borings .
Laboratory testing of subsurface soils .
Preparation and issuance of engineering reports .
All work shall also comply with the current Florida Minimum Technical Standards .
COMPENSATION .
The COUNTY agrees to pay , and the Geotechnical Professional agrees to accept, a fee for
services rendered according to the "Scope of Services" identified in the attached EXHIBIT "A. "
FTnVneeringVCapital Projects103107-8th Street, 66th-74th Ave103107 Ardaman W045 05-30-07.doc
— - 'Ardamarl & Associates ; } nc.
Geotechnical, Environmental and
Materials consultants
June 1 , 2007
Proposal File No. 07-5544
Indian River County
Engineering Division
1840 2Wh Street
Vero Beach , Florida 32960
Attention: Mr. Mike Mezzina
Subject: Proposal for Soil Permeability Testing
74"' Avenue from 4'h Street to 12th Street and
8'" Street from 66t' Avenue to 741h Avenue
Indian River County, Florida
Dear Mr. Mezzina
As requested, we are pleased topresentthe following proposal forconducting soil permeability testing
for the subject project. Based on information provided to us, we understand that the project includes
stormwaterretention swales along portions of the subject, roadways. Shallow soil stratigraphy and
permeability data and an estimate of the normal seasonal high groundwater table level are needed for
the design of the swales .
The following summarizes our proposed scope of work and associated fees for conducting the subject
exploration.
FIELD EXPLORATION
As discussed, our field exploration program will consist of performing 19 auger borings to a depth of
approximately 2 to 3 feet below the encountered groundwater table or to a maximum depth of 6 feet
below ground surface, whichever is encountered first. The borings will be conducted using a 3-inch
diameter hand (bucket) auger in the vicinity of the locations selected by the client. Each sample will be
removed from the auger in the field and then examined and visually classified by our field personnel.
Representative portions will be sealed and packaged for transportation to our laboratory for further
analysis as required . Water level observations will be made in the boreholes during the drilling
operation.
In addition, a shallow test pit will be excavated by hand adjacent to each of the boring locations to a
depth ranging from approximately 1 to 3 feet. At the bottom of the test pit, a 3-inch diameter Shelby
tube sample of soil will be obtained in a vertical orientation for permeability testing in our laboratory.
A second Shelby tube sample will also be obtained from the sidewall of each test pit in a horizontal
orientation . The boreholes and test pits will be backfilled with excavated material upon completion of
the field program .
LABORATORY TESTING
Routine laboratory visual classification will be performed along with specific classification tests deemed
necessary ( i .e . , sieve analysis , Atterberg limits and organic contents ). Constant-head laboratory
permeability tests will be performed on the Shelby tube samples obtained from the test pits.
460 Concourse Place NW, Unit 1 , Port St. Lucie, Florida 34986, Phone (772) 878-0072 FAX (772) 87&8097
Offices it Bartow. Cocoa . Fort Myers. Miami, Orlando, Port Charlotte, Port S:. Lucie, Sarasota, Tallahassee, Tampa, W. Palm Beech
' EXH I I
Indian River County -2-
Proposal File No. 07-5544
ENGINEERING ANALYSIS AND REPORT
All data obtained will be made to evaluate general subsurface conditions. The data developed during
the exploration will be submitted in a written report upon conclusion of the exploration. We will also
provide an estimate of the normal seasonal high groundwater table level at the boring locations.
COST ESTIMATE
The costs associated with the aforementioned tasks are presented below. The total cost will not be
exceeded without prior authorization . Our estimated geotechnical services are itemized as follows ;
1 . Initial Site Visit, Layout of Boring Locations and Collection of Permeability Test Samples:
Engineering technician; 40 hours @ $42.001hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 1 ,680.00
2. Auger Borings: 102linear feet @ $7. 50/foot . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . . . $
765.00
3 . Laboratory Permeability Tests: 32 tests @ $120.00/test . . . . . . .. . . . . . . . . . . . . . . . . .$ 3,840.00
4 . Percent Fines Content Tests: 16 tests @ $30. 001test . . . . . . . . . . . . . . . . . . . . . . . . . . . .$480.00
5. Engineering Services & Report Preparation :
Senior Project Engineer; 1 hour @ $98.00/hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 98.00
Project Engineer, 8 hours @ $85.00/hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $ 680.00
CAD/Technical Draftsman ; 6 hours @ S40.00/hour . . . . . . . . . . . . . . . . . . . . . . . . . . S240.00
Secretary; 2 hours @ $40 :00/hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . . .
. . . . $ 80.00
Tota/ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . $ 7, 853.00
TERMS AND CONDITIONS
This proposal is subject to the following terms and conditions: ( 1 ) access to testing locations is to be
readily available to our field personnel, (2) the proposed number tests and the associated depths will
be adequate, (3) undisturbed samples and consolidation tests on fine grained soils are not budgeted
into the total cost and (4) Ardaman & Associates cannot take responsibility for damages to underground
structures and/or services; their locations are to be provided by the client prior to commencement of the
field work.
CLOSURE
We appreciate the opportunity to submit this proposal and look forward to working with you on this
project. If this proposal meets with your approval , please indicate your acceptance by issuing the work
order that will be assigned to this project. Please call if you have any questions or require additional
information .
Sincerely,
ARDAMAN & ASSOCIATES, INC.
an . Zra lack , P . E .
'Branch Manager
Page 2 of 2
Work Order #5
8th Street from 66th Avenue to 74th Avenue and 741h Avenue from 4t ' Street to 12th Street.
A Not-to-Exceed Amount of: $7, 863 . 00 to be paid on a unit price basis for actual work
performed in accordance with the schedule of services and fees set forth in Exhibit A of
RENEWAL OF THE ANNUAL GEOTECHNICAL SERVICES CONTRACT, IRC PROJECT NO.
0534 WITH ARDAMAN & ASSOCIATES , INC . Effective Date : October 1 , 2006 .
TIME FOR COMPLETION
This Work Order No. 5 shall be performed within 60 calendar days of Notice to Proceed.
8th Street from 66th Avenue to 74th Avenue and 74th Avenue from 4th Street to 12th
Street, IRC Project #03107
IN WITNESS HEREOF the parties hereto have executed these presents
This 12th day of lnne , 2007 .
OWNER ARDAMAN & ASSOCIATES, INC.
BOARD OF COUNTY COMMSIONERS
INDIAN RIVER COUNTY, FLORIDA
Oknatur (Signa
t~ t✓ , cel% Cl�i�'iian t2att -` ` c P E.;-Brandi a `er
(e-rm?ed name and tk4e) (Printed-namW and title)
Approv6a,bX§CC` s June 12 , 2007
ATTEST :
Jeffrey K. Barton, Clerk of Circuit Court Witnessed by:
l
Maria Suesz
Deputy Clerk (Printed name)
Approved as to Form an a al ciency:
`p�m G. C Ilins II, County Attorney
C/1 N n A-) A , 0; AVI J
seph A B ird, CounN Administrator
F:\Engineering\Capital Prnjects103107-8th Street, 66th-74th Ave\03107 Ardarnan W045 05-30-OZdoc