Loading...
HomeMy WebLinkAbout2011-235 a � WORK ORDER NUMBER 1 This Work Order entered into as of this 15thday of November 20 11 pursuant to that certain Continuing Contract Agreement for Professional Services entered into as of November 15 , 2011 ( the "Agreement" ) , by and between Indian River County Solid Waste Disposal District, a dependent special district of Indian River County , Florida ( " District" ) and Geosyntec, Inc . , a Florida corporation ( " Consultant" ) . The District has selected the Consultant to perform the professional services set forth on Exhibit 1, attached to this Work Order and made part hereof by this reference . The professional services will be performed by the Consultant for the fee schedule set forth in Exhibit 1 and within the timeframe more particularly set forth in Exhibit 1 , all in accordance with the terms and provisions set forth in the Agreement . Pursuant to Agreement, nothing contained in any Work Order shall conflict with the terms of the Agreement and the terms of the Agreement shall be deemed to be incorporated in each individual Work Order as if fully set forth herein . IN WITNESS WHEREOF, the parties hereto have executed this Work Order as of the date first written above . GEOSYNTEC, INC . INDIAN RIVER COUNTY SOLID WASTE DISPOSAL DISTRICT 1 Bob Solari , Chairman Title : Senior Vice _Its' . L'. l \�I1 .� I4•h4 e:oJ�t '•a�YF�� • Attest : J . K . Barton , Clerk of Court By@ c4w� Deputy Clerk •�`�qy • 'f droved . ��`�RNfRCO\3 oseph A Baird, County Adm ' or ""yyyyy Ma " o• Approved as to form and legal sufficiency Alan S . Polackwi , Sr . , C ty Attorney a � WORK ORDER NUMBER 1 This Work Order entered into as of this 15thday of November 20 11 pursuant to that certain Continuing Contract Agreement for Professional Services entered into as of November 15 , 2011 ( the "Agreement" ) , by and between Indian River County Solid Waste Disposal District, a dependent special district of Indian River County , Florida ( " District" ) and Geosyntec, Inc . , a Florida corporation ( " Consultant" ) . The District has selected the Consultant to perform the professional services set forth on Exhibit 1, attached to this Work Order and made part hereof by this reference . The professional services will be performed by the Consultant for the fee schedule set forth in Exhibit 1 and within the timeframe more particularly set forth in Exhibit 1 , all in accordance with the terms and provisions set forth in the Agreement . Pursuant to Agreement, nothing contained in any Work Order shall conflict with the terms of the Agreement and the terms of the Agreement shall be deemed to be incorporated in each individual Work Order as if fully set forth herein . IN WITNESS WHEREOF, the parties hereto have executed this Work Order as of the date first written above . GEOSYNTEC, INC . INDIAN RIVER COUNTY SOLID WASTE DISPOSAL DISTRICT 1 Bob Solari , Chairman Title : Senior Vice _Its' . L'. l \�I1 .� I4•h4 e:oJ�t '•a�YF�� • Attest : J . K . Barton , Clerk of Court By@ c4w� Deputy Clerk •�`�qy • 'f droved . ��`�RNfRCO\3 oseph A Baird, County Adm ' or ""yyyyy Ma " o• Approved as to form and legal sufficiency Alan S . Polackwi , Sr . , C ty Attorney EXHIBIT 1 PROFESSIONAL SERVICES enghieers I st ieritists I innowltors EXHIBIT 1 PROFESSIONAL SERVICES enghieers I st ieritists I innowltors 710 Geosyntec ' 1200 Riverplace Boulevard, Suite 207�/' Jacksonville, Florida 32207 PH 904. 858 . 1818 consultants FAX 904 . 396 . 1143 www. geosyntee.corn 3 November 2011 Mr . Himanshu Mehta, P . E . , Managing Director Solid Waste Disposal District Indian River County 1325 74th Avenue SW Vero Beach , Florida 32968 Subject : Proposal for Engineering Services Title V Air Operation Permit Renewal Application Indian River County Landfill Facility Vero Beach , Indian River County , Florida Dear Mr. Himanshu Geosyntec Consultants , Inc . (Geosyntec ) is pleased to submit this proposal to Indian River County ( IRC) , Solid Waste Disposal District ( SWDD) to provide engineering services related to the renewal of the five - year Title V Air Operation Permit for the IRC Landfill ( IRCL) facility . The current 5 -year permit will expire on June 30 , 2012 with the renewal application due on December 31 , 2011 . The proposal presents the scope of work, schedule, and budget estimate for the preparation and submittal to the Florida Department of Environmental Protection (FDEP) the application for the renewal permit, including Tier 2 testing and analysis to estimate the annual quantity of nonmethane organic compounds (NMOC) emissions from the IRC Class I landfill , and responding to any requests for additional information ( RAIs) by the FDEP . The proposal was prepared in response to a verbal request from Mr . Himanshu Mehta, P . E . , Managing Director, of SWDD , during a 2 November 2011 telephone conversation with Dr. Kwasi Badu- Tweneboah , P . E . of Geosyntec . Geosyntec has prepared this proposal as Exhibit I to Work Order No . 1 for the Continuing Contract Agreement for Professional Services between IRC SWDD and Geosyntec , dated 15 November 2011 . The remainder of this proposal presents : (i ) project background ; ( ii) proposed scope of work ; ( iii ) schedule ; and ( iv ) budget estimate . PROJECT BACKGROUND The IRCL facility is located in southern Indian River County, east of Interstate 95 , south of Oslo Road , and west of Rangeline Road in Vero Beach , Florida. The landfill serves the unincorporated Indian River County and municipalities of Vero Beach , Orchid , Fellsmere , Sebastian , and Indian River Shores . The SWDD administers the management and operation of the Class I landfill at the IRCL facility, and as such , it is the permit holder of the IRCL facility . NCP201 I \XL I 1275\J L I 1126_Title V Proposal . doc engineers I Sc' ielltists I innovators 710 Geosyntec ' 1200 Riverplace Boulevard, Suite 207�/' Jacksonville, Florida 32207 PH 904. 858 . 1818 consultants FAX 904 . 396 . 1143 www. geosyntee.corn 3 November 2011 Mr . Himanshu Mehta, P . E . , Managing Director Solid Waste Disposal District Indian River County 1325 74th Avenue SW Vero Beach , Florida 32968 Subject : Proposal for Engineering Services Title V Air Operation Permit Renewal Application Indian River County Landfill Facility Vero Beach , Indian River County , Florida Dear Mr. Himanshu Geosyntec Consultants , Inc . (Geosyntec ) is pleased to submit this proposal to Indian River County ( IRC) , Solid Waste Disposal District ( SWDD) to provide engineering services related to the renewal of the five - year Title V Air Operation Permit for the IRC Landfill ( IRCL) facility . The current 5 -year permit will expire on June 30 , 2012 with the renewal application due on December 31 , 2011 . The proposal presents the scope of work, schedule, and budget estimate for the preparation and submittal to the Florida Department of Environmental Protection (FDEP) the application for the renewal permit, including Tier 2 testing and analysis to estimate the annual quantity of nonmethane organic compounds (NMOC) emissions from the IRC Class I landfill , and responding to any requests for additional information ( RAIs) by the FDEP . The proposal was prepared in response to a verbal request from Mr . Himanshu Mehta, P . E . , Managing Director, of SWDD , during a 2 November 2011 telephone conversation with Dr. Kwasi Badu- Tweneboah , P . E . of Geosyntec . Geosyntec has prepared this proposal as Exhibit I to Work Order No . 1 for the Continuing Contract Agreement for Professional Services between IRC SWDD and Geosyntec , dated 15 November 2011 . The remainder of this proposal presents : (i ) project background ; ( ii) proposed scope of work ; ( iii ) schedule ; and ( iv ) budget estimate . PROJECT BACKGROUND The IRCL facility is located in southern Indian River County, east of Interstate 95 , south of Oslo Road , and west of Rangeline Road in Vero Beach , Florida. The landfill serves the unincorporated Indian River County and municipalities of Vero Beach , Orchid , Fellsmere , Sebastian , and Indian River Shores . The SWDD administers the management and operation of the Class I landfill at the IRCL facility, and as such , it is the permit holder of the IRCL facility . NCP201 I \XL I 1275\J L I 1126_Title V Proposal . doc engineers I Sc' ielltists I innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 2 This landfill facility is currently operating under Title V Air Operation Permit No . 0610015 - 003 - AV , effective July 19 , 2007 . The existing Class I Landfill has a voluntarily- installed gas collection and control system (GCCS ) for those areas at final grades . Segment 1 , Segment 2 , and the Infill Area of the IRCL have an existing GCCS that consists of vertical and horizontal gas extraction wells , gas collection lateral and header pipes, blower, and flare . Collected landfill gas is piped to a flare/blower system , located immediately east of Segment 2 , where the combustible components are oxidized by incineration . SWDD has recently entered into an agreement for the sale of the landfill gas to an adjacent waste4o- ethanol facility , presently under construction , for use as a supplemental fuel for the process . Geosyntec also understands that the IRCL facility is currently regulated under the New Source Performance Standards (NSPS ) for municipal solid waste ( MSW) landfills as identified in Subpart WWW of 40 CFR, Part 60 ( Subpart WWW) . An NSPS Tier 2 NMOC emissions rate report was prepared and submitted to FDEP as part of the Title V renewal permit application in January 2007 . A similar Tier 2 testing will be performed to estimate the site - specific NMOC concentration to recalculate and submit a Tier 2 NMOC emission rate report as part of this 2011 Title V renewal permit application . PROPOSED SCOPE OF WORK This project includes professional engineering services required to renew the Title V Air Operation Permit for the IRCL facility . The scope of work is based on the requirements of Chapter 403 , Florida Statue ( F . S .) , Florida Administrative Code (F . A . C .) Chapters 624 , 62-210 and 62 -213 ) , and Geosyntec ' s understanding of the project based on information provided by SWDD . Geosyntec will provide all engineering services necessary to prepare the 5 - year renewal permit application , including sampling and testing the landfill gas to calculate the NMOC , and address any request for additional information ( RAI ) from FDEP . For budgeting purposes , the scope of work will be performed in four phases as follows : • Phase 1 — General Consulting/Meeting Support/ Project Management ; • Phase 2 — Tier 2 Testing and Reporting ; • Phase 3 — Title V Renewal Permit Application ; and • Phase 4 — Response to Regulatory Comments . Each of these phases is briefly described below . NCP201IAL11275UL1 1126 Title V Proposal . doc enI lteryrs ( ti : ixl � titti I innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 2 This landfill facility is currently operating under Title V Air Operation Permit No . 0610015 - 003 - AV , effective July 19 , 2007 . The existing Class I Landfill has a voluntarily- installed gas collection and control system (GCCS ) for those areas at final grades . Segment 1 , Segment 2 , and the Infill Area of the IRCL have an existing GCCS that consists of vertical and horizontal gas extraction wells , gas collection lateral and header pipes, blower, and flare . Collected landfill gas is piped to a flare/blower system , located immediately east of Segment 2 , where the combustible components are oxidized by incineration . SWDD has recently entered into an agreement for the sale of the landfill gas to an adjacent waste4o- ethanol facility , presently under construction , for use as a supplemental fuel for the process . Geosyntec also understands that the IRCL facility is currently regulated under the New Source Performance Standards (NSPS ) for municipal solid waste ( MSW) landfills as identified in Subpart WWW of 40 CFR, Part 60 ( Subpart WWW) . An NSPS Tier 2 NMOC emissions rate report was prepared and submitted to FDEP as part of the Title V renewal permit application in January 2007 . A similar Tier 2 testing will be performed to estimate the site - specific NMOC concentration to recalculate and submit a Tier 2 NMOC emission rate report as part of this 2011 Title V renewal permit application . PROPOSED SCOPE OF WORK This project includes professional engineering services required to renew the Title V Air Operation Permit for the IRCL facility . The scope of work is based on the requirements of Chapter 403 , Florida Statue ( F . S .) , Florida Administrative Code (F . A . C .) Chapters 624 , 62-210 and 62 -213 ) , and Geosyntec ' s understanding of the project based on information provided by SWDD . Geosyntec will provide all engineering services necessary to prepare the 5 - year renewal permit application , including sampling and testing the landfill gas to calculate the NMOC , and address any request for additional information ( RAI ) from FDEP . For budgeting purposes , the scope of work will be performed in four phases as follows : • Phase 1 — General Consulting/Meeting Support/ Project Management ; • Phase 2 — Tier 2 Testing and Reporting ; • Phase 3 — Title V Renewal Permit Application ; and • Phase 4 — Response to Regulatory Comments . Each of these phases is briefly described below . NCP201IAL11275UL1 1126 Title V Proposal . doc enI lteryrs ( ti : ixl � titti I innovators Mr. Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 3 Phase 1 — General Consulting/Meeting Support/Project Management Under this phase , Geosyntec will perform project planning and management responsibilities, such as correspondence with SWDD and FDEP, invoice review , project coordination, budget and schedule tracking and project administration . Geosyntec has also included a budget for preparation and attendance (by two Geosyntec personnel ) at two meetings : (i ) kickoff meeting with SWDD staff to obtain information required to complete the application ; and (ii ) a meeting with FDEP and SWDD to present the complete application and respond to questions . Phase 2 —Tier 2 Testing and Reporting The scope of the Tier 2 testing and reporting phase includes the development of a test plan , field gas sampling, laboratory analysis, data evaluation , and reporting . We will collect gas samples from the existing gas collection system at a location prior to the flare station ' s blower and condensate knockout . Three samples will be collected in passivated SUMMA canisters and sent under chain - of- custody protocol to an analytical laboratory for testing . Samples will be analyzed for nitrogen by EPA Method 3C to validate the sample ( i . e . , confirm minimal air intrusion occurred ) . Upon sample validation , the samples will be analyzed for NMOCs by EPA Method 25C . Sample collection and analysis will be performed by TRC Environmental Corporation , Gainesville , Florida (TRC ) as a subcontractor to Geosyntec . A copy of TRC ' s proposal is included as Attachment A . Geosyntec will review the analytical results , estimate annual NMOC mass emission rates, and prepare an NSPS Tier 2 NMOC emissions rate report that summarizes sampling and analysis activities and results . Data analysis will include the calculation of NMOC concentrations based on laboratory analysis and waste acceptance rates . Geosyntec will use the EPA ' s Landfill Gas Emissions Model Version 3 . 02 to estimate the NMOC emission rate . Results and conclusions regarding the need for compliance with the additional NSPS monitoring and reporting requirements of the Class I landfill will be based on the regulatory threshold of 50 Mg/yr of NMOC generation . Phase 3 — Title V Renewal Permit Application Geosyntec will prepare the FDEP Title V Air Operation renewal permit application for the IRC landfill . Geosyntec will complete FDEP, Division of Air Resource Management Form No . 62 - 210 . 900 ( 1 ) titled "Application for Air Permit - Long Form " and address the additional information items required by the form . The following activities will be performed to prepare the renewal permit application : NCP201 I \XL11275\JLl 1126 Title V Proposal . doc engineers P Scientists I innovators Mr. Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 3 Phase 1 — General Consulting/Meeting Support/Project Management Under this phase , Geosyntec will perform project planning and management responsibilities, such as correspondence with SWDD and FDEP, invoice review , project coordination, budget and schedule tracking and project administration . Geosyntec has also included a budget for preparation and attendance (by two Geosyntec personnel ) at two meetings : (i ) kickoff meeting with SWDD staff to obtain information required to complete the application ; and (ii ) a meeting with FDEP and SWDD to present the complete application and respond to questions . Phase 2 —Tier 2 Testing and Reporting The scope of the Tier 2 testing and reporting phase includes the development of a test plan , field gas sampling, laboratory analysis, data evaluation , and reporting . We will collect gas samples from the existing gas collection system at a location prior to the flare station ' s blower and condensate knockout . Three samples will be collected in passivated SUMMA canisters and sent under chain - of- custody protocol to an analytical laboratory for testing . Samples will be analyzed for nitrogen by EPA Method 3C to validate the sample ( i . e . , confirm minimal air intrusion occurred ) . Upon sample validation , the samples will be analyzed for NMOCs by EPA Method 25C . Sample collection and analysis will be performed by TRC Environmental Corporation , Gainesville , Florida (TRC ) as a subcontractor to Geosyntec . A copy of TRC ' s proposal is included as Attachment A . Geosyntec will review the analytical results , estimate annual NMOC mass emission rates, and prepare an NSPS Tier 2 NMOC emissions rate report that summarizes sampling and analysis activities and results . Data analysis will include the calculation of NMOC concentrations based on laboratory analysis and waste acceptance rates . Geosyntec will use the EPA ' s Landfill Gas Emissions Model Version 3 . 02 to estimate the NMOC emission rate . Results and conclusions regarding the need for compliance with the additional NSPS monitoring and reporting requirements of the Class I landfill will be based on the regulatory threshold of 50 Mg/yr of NMOC generation . Phase 3 — Title V Renewal Permit Application Geosyntec will prepare the FDEP Title V Air Operation renewal permit application for the IRC landfill . Geosyntec will complete FDEP, Division of Air Resource Management Form No . 62 - 210 . 900 ( 1 ) titled "Application for Air Permit - Long Form " and address the additional information items required by the form . The following activities will be performed to prepare the renewal permit application : NCP201 I \XL11275\JLl 1126 Title V Proposal . doc engineers P Scientists I innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 4 • Facility plot plan ; • Process flow diagram ; • Precautions to prevent emissions of unconfined particulate matter; • List of insignificant activities ; • Identification of applicable requirements ; • Compliance report and plan • changes to current Title V Air Operation Permit ; • Fuel analysis or specification ; • Detailed description of control equipment; • Procedures for startup and shutdown ; • Operation and maintenance plan ; • Previously submitted information ; and • Identification of applicable requirements Geosyntec will describe the existing emission control system for IRCL facility , and calculate the emissions of air pollutants expected to be released into the environment by its operation . Geosyntec will complete the required FDEP Form 62 -210 . 900( 1 ) , and prepare a transmittal letter to FDEP that summarizes the renewal permit application package . Phase 4 — Response to Regulatory Comments Following submittal of the Renewal Permit Application , Geosyntec will meet with Central District office of the FDEP Air Resource Management Division to present and discuss the application package . Geosyntec will provide FDEP with written responses to RAIs throughout the course of the permit application review process . For the purpose of the budget estimate, Geosyntec has estimated one response to FDEP RAI will be required . SCHEDULE Geosyntec will initiate work immediately upon receipt of Notice to Proceed (NTP) from SWDD . Geosyntec has assumed that this NTP would be issued no later than 16 November 2011 in order NCP2011 \XL11275\JLI I126_Tide V Proposal . doc engineers I scientists 1 innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 4 • Facility plot plan ; • Process flow diagram ; • Precautions to prevent emissions of unconfined particulate matter; • List of insignificant activities ; • Identification of applicable requirements ; • Compliance report and plan • changes to current Title V Air Operation Permit ; • Fuel analysis or specification ; • Detailed description of control equipment; • Procedures for startup and shutdown ; • Operation and maintenance plan ; • Previously submitted information ; and • Identification of applicable requirements Geosyntec will describe the existing emission control system for IRCL facility , and calculate the emissions of air pollutants expected to be released into the environment by its operation . Geosyntec will complete the required FDEP Form 62 -210 . 900( 1 ) , and prepare a transmittal letter to FDEP that summarizes the renewal permit application package . Phase 4 — Response to Regulatory Comments Following submittal of the Renewal Permit Application , Geosyntec will meet with Central District office of the FDEP Air Resource Management Division to present and discuss the application package . Geosyntec will provide FDEP with written responses to RAIs throughout the course of the permit application review process . For the purpose of the budget estimate, Geosyntec has estimated one response to FDEP RAI will be required . SCHEDULE Geosyntec will initiate work immediately upon receipt of Notice to Proceed (NTP) from SWDD . Geosyntec has assumed that this NTP would be issued no later than 16 November 2011 in order NCP2011 \XL11275\JLI I126_Tide V Proposal . doc engineers I scientists 1 innovators ATTACHMENT A TIER 2 TESTING PROPOSAL engineers I scientists I innovators ATTACHMENT A TIER 2 TESTING PROPOSAL engineers I scientists I innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 5 for us to complete the work and submit the Title V Air Operation Renewal Permit Application to FDEP before the deadline of December 31 , 2011 . BUDGET ESTIMATE A budget estimate for the scope of work outlined in this proposal is summarized in the following table , and a detailed budget estimate is provided as Attachment B . Note that the budget estimate for Phase 2 includes TRC ' s fees for collecting the samples and testing . The budget estimate does not include permit fees that will be required at the time the permit application is submitted to FDEP . Phase 1 — General Consulting/Meeting Support/Project Management $ 99523 Phase 2 — Tier 2 Testing and Reporting $ 12 , 353 Phase 3 — Title V Renewal Permit Application $26 , 885 Phase 4 : Response to Regulatory Comments 3 341 Total Budget Estimate $ 529101 Geosyntec will not exceed the cost estimate without prior approval and written authorization from SWDD . CLOSURE Geosyntec appreciates this opportunity to offer our services . If this proposal is acceptable , please indicate your agreement by signing the attached work authorization , which references this proposal . Please return one signed work authorization to Dr . Badu -Tweneboah ' s attention . Please call the undersigned with questions you may have as you review this proposal . Sincerelv . Tanhum Goldshmid , Ph . D . Senior Consultant Kwasi Badu -Tweneboah , Ph . D . , P . E . Associate Attachments NCP201IALI 1275\JLI I126_Title V Proposal . doc engineers I scientists I innovators Mr . Himanshu Mehta, P . E . Managing Director 3 November 2011 Page 5 for us to complete the work and submit the Title V Air Operation Renewal Permit Application to FDEP before the deadline of December 31 , 2011 . BUDGET ESTIMATE A budget estimate for the scope of work outlined in this proposal is summarized in the following table , and a detailed budget estimate is provided as Attachment B . Note that the budget estimate for Phase 2 includes TRC ' s fees for collecting the samples and testing . The budget estimate does not include permit fees that will be required at the time the permit application is submitted to FDEP . Phase 1 — General Consulting/Meeting Support/Project Management $ 99523 Phase 2 — Tier 2 Testing and Reporting $ 12 , 353 Phase 3 — Title V Renewal Permit Application $26 , 885 Phase 4 : Response to Regulatory Comments 3 341 Total Budget Estimate $ 529101 Geosyntec will not exceed the cost estimate without prior approval and written authorization from SWDD . CLOSURE Geosyntec appreciates this opportunity to offer our services . If this proposal is acceptable , please indicate your agreement by signing the attached work authorization , which references this proposal . Please return one signed work authorization to Dr . Badu -Tweneboah ' s attention . Please call the undersigned with questions you may have as you review this proposal . Sincerelv . Tanhum Goldshmid , Ph . D . Senior Consultant Kwasi Badu -Tweneboah , Ph . D . , P . E . Associate Attachments NCP201IALI 1275\JLI I126_Title V Proposal . doc engineers I scientists I innovators 6322 NW 18th Drive Suite 170 Gainesville , FL 32653 352 . 378 . 0332 PHONE 352 . 378 . 0354 FAX www. TRCsolutions . com Submitted via e-mail KBaduTweneboah (& Geosyn tec. com November 3 , 2011 Mr. Kwasi Badu-Tweneboah, Ph . D . , P . E. Geosyntec Consultants 120o Riverplace Boulevard, Suit 710 Jacksonville, Florida 32207 Re : TRC Proposal No . 188759 . 999o . 0000 Tier II Sampling Project — Lake County Landfill Dear Mr. Badu-Tweneboah, I I TRC Environmental Corporation , Gainesville Office (TRC) is pleased to submit this proposal to Geosyntec Consultants (Geosyntec) to conduct landfill gas Tier II sampling at a municipal solid waste (MSW) landfill in Vero Beach, Indian River County, Florida. We believe that with 15 years of landfill gas Tier II testing experience and our long standing reputation of providing quality work to clients, that TRC is the best choice for providing your Tier II landfill gas emission services . j Test Program Scope of Work I TRC will provide the labor, equipment, and technical expertise required to conduct your testing program as outlined below. The testing will be conducted at a landfill located in f Indian River County by an Associate Project Manager . The actual mobilization, testing and equipment set-up and sampling, and demobilization will be conducted over a one day schedule. All testing shall be conducted in one mobilization . w The actual scope of work is to consist of the collection of landfill gas samples from the I common header at a location prior to any condensate removal system at the Indian River Landfil . Samples will be collected into 6 or 8 liter SUMMA passivated canisters (supplied by an analytical laboratory) , pre-charged halfway with Helium, in accordance with EPA Method 25C protocols . A total of three samples shall be collected over a 20 minute sample 1 I ^ 1 � I 6322 NW 18th Drive Suite 170 Gainesville , FL 32653 352 . 378 . 0332 PHONE 352 . 378 . 0354 FAX www. TRCsolutions . com Submitted via e-mail KBaduTweneboah (& Geosyn tec. com November 3 , 2011 Mr. Kwasi Badu-Tweneboah, Ph . D . , P . E. Geosyntec Consultants 120o Riverplace Boulevard, Suit 710 Jacksonville, Florida 32207 Re : TRC Proposal No . 188759 . 999o . 0000 Tier II Sampling Project — Lake County Landfill Dear Mr. Badu-Tweneboah, I I TRC Environmental Corporation , Gainesville Office (TRC) is pleased to submit this proposal to Geosyntec Consultants (Geosyntec) to conduct landfill gas Tier II sampling at a municipal solid waste (MSW) landfill in Vero Beach, Indian River County, Florida. We believe that with 15 years of landfill gas Tier II testing experience and our long standing reputation of providing quality work to clients, that TRC is the best choice for providing your Tier II landfill gas emission services . j Test Program Scope of Work I TRC will provide the labor, equipment, and technical expertise required to conduct your testing program as outlined below. The testing will be conducted at a landfill located in f Indian River County by an Associate Project Manager . The actual mobilization, testing and equipment set-up and sampling, and demobilization will be conducted over a one day schedule. All testing shall be conducted in one mobilization . w The actual scope of work is to consist of the collection of landfill gas samples from the I common header at a location prior to any condensate removal system at the Indian River Landfil . Samples will be collected into 6 or 8 liter SUMMA passivated canisters (supplied by an analytical laboratory) , pre-charged halfway with Helium, in accordance with EPA Method 25C protocols . A total of three samples shall be collected over a 20 minute sample 1 I ^ 1 � I i i Mr. Kwasi Badu-Tweneboah November 3 , 2011 Geosyntec Consultants i i period per canister. The budget includes shipment of samples to and from an analytical laboratory (2 day air with tracking labels) for analysis via EPA Methods 3C and 25C. Geosyntec or the landfill owner shall supply a landfill gas analyzer to purge the sampling system and verify the validity of the landfill gas (must contain less than 5% oxygen) just prior to sample collection . i Deliverables TRC will submit a draft copy of the test report within ten ( 10 ) business days of the completion of the sampling program . The final report (up to 6 copies) shall be submitted within five (5) business days of receiving client comments . Final reports will include an introduction, summary of results, process description, description of all test and analytical methodologies, quality assurance and quality control measures and results , and copies of the analytical data . Program Price TRC proposes to perform the sampling program described above on a Fixed Price Basis in accordance with the terms and conditions noted in Table 1 . The cost for each of the testing options is shown in the following table . TABLE 1 — TESTING COSTS pyx �( �F i "VI 7 � � k � � E �,i� � t 1x � QM r, < 5 . ,, , . -. _ ,. .,r r e q °(= c x.p. � . .,. mc�E , a, � �e, i.tx MIS �. r{ 4� �,u �� � �.,�+ o-'£ � �� •� _' Base Price — Testing per Scope $ 4,776 TRC Supplies LFG Analyzer with Add $475 built in pump for testing Client Delays/Added Testing See Below f These costs include all mobilization, travel , and per diem costs for the test team . If delays are encountered, or if additional out- of-scope testing is performed at the request of Geosyntec, the costs for additional time on-site over the hours per day specified in this proposal will be charged at a rate of $ 8o per hour per person. If additional night layovers are required a $ 150 per diem per person will be charged. Work performed over 12-hours 1 per day or on weekends shall be charged at overtime rates of $ 120 . 00 per person . � 2 � I i i Mr. Kwasi Badu-Tweneboah November 3 , 2011 Geosyntec Consultants i i period per canister. The budget includes shipment of samples to and from an analytical laboratory (2 day air with tracking labels) for analysis via EPA Methods 3C and 25C. Geosyntec or the landfill owner shall supply a landfill gas analyzer to purge the sampling system and verify the validity of the landfill gas (must contain less than 5% oxygen) just prior to sample collection . i Deliverables TRC will submit a draft copy of the test report within ten ( 10 ) business days of the completion of the sampling program . The final report (up to 6 copies) shall be submitted within five (5) business days of receiving client comments . Final reports will include an introduction, summary of results, process description, description of all test and analytical methodologies, quality assurance and quality control measures and results , and copies of the analytical data . Program Price TRC proposes to perform the sampling program described above on a Fixed Price Basis in accordance with the terms and conditions noted in Table 1 . The cost for each of the testing options is shown in the following table . TABLE 1 — TESTING COSTS pyx �( �F i "VI 7 � � k � � E �,i� � t 1x � QM r, < 5 . ,, , . -. _ ,. .,r r e q °(= c x.p. � . .,. mc�E , a, � �e, i.tx MIS �. r{ 4� �,u �� � �.,�+ o-'£ � �� •� _' Base Price — Testing per Scope $ 4,776 TRC Supplies LFG Analyzer with Add $475 built in pump for testing Client Delays/Added Testing See Below f These costs include all mobilization, travel , and per diem costs for the test team . If delays are encountered, or if additional out- of-scope testing is performed at the request of Geosyntec, the costs for additional time on-site over the hours per day specified in this proposal will be charged at a rate of $ 8o per hour per person. If additional night layovers are required a $ 150 per diem per person will be charged. Work performed over 12-hours 1 per day or on weekends shall be charged at overtime rates of $ 120 . 00 per person . � 2 � I A I Mr. Kwasi Badu-Tweneboah November 3 , 2011 I Geosyntee Consultants I Items Supplied by Client I The cost of this proposal is based on the client providing the following items in order to complete the sampling program . i i . The proposal cost is based on the facility providing safe access for the test crew to all of the sampling locations, including vehicular access . 2 . The client shall verify the sampling site location and confirm that there is a sample port located on the common header prior to the condensate removal system . 3 . If there is not a sampling location, then the client shall install a sampling location prior to TRC mobilization . 4 . The landfill shall additionally supply a portable landfill gas analyzer equipped with a sample pump to purge the sample train and verify the quality of the landfill gas prior to filling the sample canisters . Completion Schedule i The final schedule will be confirmed upon project award. Proposal Period l The detailed cost presented in this proposal is valid for go days from the date on the cover page of this proposal ( November 3 , 2011) . Invoice Terms i TRC will submit a single lump sum invoice upon completion of the field sampling. Payment terms are net 3o days . i You may engage our services by signing and returning the authorization form (Attachment A) attached to this letter. Alternatively, you may issue a purchase order or contract that references TRC Proposal No . 188759 . 9990 . 000o dated November 3 , 2011 . TRC appreciates this opportunity to provide Geosyntec with this proposal . We are looking forward to providing you with our emissions testing services . If you have any questions f regarding this proposal or need changes and/or modifications to the sampling program, please contact me at (352) 378 - 0332 (Office) , (352) 317- 0041 (Cellular) or lbrenner (@tresolutions . com . 3 A I Mr. Kwasi Badu-Tweneboah November 3 , 2011 I Geosyntee Consultants I Items Supplied by Client I The cost of this proposal is based on the client providing the following items in order to complete the sampling program . i i . The proposal cost is based on the facility providing safe access for the test crew to all of the sampling locations, including vehicular access . 2 . The client shall verify the sampling site location and confirm that there is a sample port located on the common header prior to the condensate removal system . 3 . If there is not a sampling location, then the client shall install a sampling location prior to TRC mobilization . 4 . The landfill shall additionally supply a portable landfill gas analyzer equipped with a sample pump to purge the sample train and verify the quality of the landfill gas prior to filling the sample canisters . Completion Schedule i The final schedule will be confirmed upon project award. Proposal Period l The detailed cost presented in this proposal is valid for go days from the date on the cover page of this proposal ( November 3 , 2011) . Invoice Terms i TRC will submit a single lump sum invoice upon completion of the field sampling. Payment terms are net 3o days . i You may engage our services by signing and returning the authorization form (Attachment A) attached to this letter. Alternatively, you may issue a purchase order or contract that references TRC Proposal No . 188759 . 9990 . 000o dated November 3 , 2011 . TRC appreciates this opportunity to provide Geosyntec with this proposal . We are looking forward to providing you with our emissions testing services . If you have any questions f regarding this proposal or need changes and/or modifications to the sampling program, please contact me at (352) 378 - 0332 (Office) , (352) 317- 0041 (Cellular) or lbrenner (@tresolutions . com . 3 Mr . Kwasi Badu-Tweneboah November 3 , 2011 Geosyntec Consultants Sincerely, i L onard Bren r, Senior Project Manager TRC i Air Measurements — Gainesville Office 6322 NW 18th Drive , Suite 170 { Gainesville , Florida32653 (352) 378 - 0332 Office (352) 378 - 0354 Facsimile I (352 ) 317- 0041 Cellular Email : lbrenner0tresolutions . com I E I G I i I I I r I I Mr . Kwasi Badu-Tweneboah November 3 , 2011 Geosyntec Consultants Sincerely, i L onard Bren r, Senior Project Manager TRC i Air Measurements — Gainesville Office 6322 NW 18th Drive , Suite 170 { Gainesville , Florida32653 (352) 378 - 0332 Office (352) 378 - 0354 Facsimile I (352 ) 317- 0041 Cellular Email : lbrenner0tresolutions . com I E I G I i I I I r I I i I i i ATTACHMENT A AUTHORIZATION TO PROCEED i I I I accept the fee structure and the terms and conditions of TRC Proposal No . i88759 . 9990 . 000o dated November 3 , 2011 authorize TRC to proceed with this project. GEOSYNTEC CONSULTANTS i Company Name i Company Representative Title Signature Date E I 1 i i i i I i i ATTACHMENT A AUTHORIZATION TO PROCEED i I I I accept the fee structure and the terms and conditions of TRC Proposal No . i88759 . 9990 . 000o dated November 3 , 2011 authorize TRC to proceed with this project. GEOSYNTEC CONSULTANTS i Company Name i Company Representative Title Signature Date E I 1 i i i ATTACHMENT B DETAILED BUDGET ESTIMATE engineers I scientists I innovators ATTACHMENT B DETAILED BUDGET ESTIMATE engineers I scientists I innovators Table 1 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 1 : PROJECT MANAGEMENT/ MEETINGS ITEM BASIS RATE QUANTITY ESTIMATED COST A. Professional Services a . Principal Hr $ 196 0 $ 0 b . Associate Hr $ 185 24 $4 , 448 c . Senior Project Engineer Hr $ 163 24 $ 3 , 914 d . Project Engineer Hr $ 129 1 0 $ 0 e . Engineer Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 0 $ 0 g . Staff Engineer Hr $ 84 0 $ 0 Subtotal Professional Services $ 8 , 361 B. Technical/Administrative Services a . CADD Designer Hr $ 119 0 $ 0 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 4 $ 332 e . Clerical Hr $ 50 1 4 $200 Subtotal Technical/Administrative Services $ 532 C . `' Reimbursables a . Lodging Day $ 100 0 $ 0 b . Per Diem ` Day $21 0 $ 0 c . Communications Fee 3 % Labor 0 . 03 $ 8 , 894 $267 d . CADD Computer System Hr $ 15 2 $ 30 e . Vehicle Rental & Fuel ` Day $ 150 2 $ 300 f. 8"x11 " Photocopies Each $ 0 . 12 25 $ 3 g . CADD Drawings Each $ 3 10 $ 30 Subtotal Reimbursables $ 630 TOTAL ESTIMATED BUDGET : 'PHASE 01 $9 523 * In compliance with Section 112 . 061 F . S . XL11275/Budget Estimate Geosyntec Consultants Table 1 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 1 : PROJECT MANAGEMENT/ MEETINGS ITEM BASIS RATE QUANTITY ESTIMATED COST A. Professional Services a . Principal Hr $ 196 0 $ 0 b . Associate Hr $ 185 24 $4 , 448 c . Senior Project Engineer Hr $ 163 24 $ 3 , 914 d . Project Engineer Hr $ 129 1 0 $ 0 e . Engineer Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 0 $ 0 g . Staff Engineer Hr $ 84 0 $ 0 Subtotal Professional Services $ 8 , 361 B. Technical/Administrative Services a . CADD Designer Hr $ 119 0 $ 0 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 4 $ 332 e . Clerical Hr $ 50 1 4 $200 Subtotal Technical/Administrative Services $ 532 C . `' Reimbursables a . Lodging Day $ 100 0 $ 0 b . Per Diem ` Day $21 0 $ 0 c . Communications Fee 3 % Labor 0 . 03 $ 8 , 894 $267 d . CADD Computer System Hr $ 15 2 $ 30 e . Vehicle Rental & Fuel ` Day $ 150 2 $ 300 f. 8"x11 " Photocopies Each $ 0 . 12 25 $ 3 g . CADD Drawings Each $ 3 10 $ 30 Subtotal Reimbursables $ 630 TOTAL ESTIMATED BUDGET : 'PHASE 01 $9 523 * In compliance with Section 112 . 061 F . S . XL11275/Budget Estimate Geosyntec Consultants Table 2 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 2 : Tier 2 Testing & Reporting ITEM BASIS RATE QUANTITY ESTIMATED COST A. Professional Services a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 4 $740 c . Senior Project Engineer Hr $ 163 8 $ 1 , 304 d . Project Engineer Hr $ 129 0 $ 0 e . Engineer -- Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 16 $ 1 , 600 g . Staff Engineer Hr $84 0 $0 Subtotal Professional Services $3 , 644 B. Technical/Administrative Services a . CADD Designer Hr $ 119 8 $952 b . Drafter/CADD Operator/Artist Hr $ 117 0 $ 0 c . Technical/Administrative Assistant Hr $ 81 4 $ 324 d . Technical Word Processor Hr $ 83 8 $664 e . Clerical Hr $ 50 4 $200 Subtotal Technical/Administrative Services $2 , 140 Cm Reimbursables a . Lodging Da $ 75 0 $ 0 b . Per Diem ' Da $21 0 $0 c . Communications Fee 3 % Labor 0 . 03 $ 5 , 784 $ 174 d . CADD Computer System Hr $ 15 8 $ 120 e . Sampling & Testing Subcontractor Est $ 5 , 500 . 00 1 . 07 $5 , 885 f. Vehicle Rental & Fuel ' Da $ 150 . 00 2 $300 g . 8 "x11 " Photocopies Each $ 0 . 12 500 $60 h . CADD Drawings Each $3 10 $ 30 Subtotal Reimbursables $ 6 , 569 TOTAL ESTIMATED BUDGET : PHASE 02 12 353 ' In compliance with Section 112 . 061 F . S . Table 2 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 2 : Tier 2 Testing & Reporting ITEM BASIS RATE QUANTITY ESTIMATED COST A. Professional Services a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 4 $740 c . Senior Project Engineer Hr $ 163 8 $ 1 , 304 d . Project Engineer Hr $ 129 0 $ 0 e . Engineer -- Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 16 $ 1 , 600 g . Staff Engineer Hr $84 0 $0 Subtotal Professional Services $3 , 644 B. Technical/Administrative Services a . CADD Designer Hr $ 119 8 $952 b . Drafter/CADD Operator/Artist Hr $ 117 0 $ 0 c . Technical/Administrative Assistant Hr $ 81 4 $ 324 d . Technical Word Processor Hr $ 83 8 $664 e . Clerical Hr $ 50 4 $200 Subtotal Technical/Administrative Services $2 , 140 Cm Reimbursables a . Lodging Da $ 75 0 $ 0 b . Per Diem ' Da $21 0 $0 c . Communications Fee 3 % Labor 0 . 03 $ 5 , 784 $ 174 d . CADD Computer System Hr $ 15 8 $ 120 e . Sampling & Testing Subcontractor Est $ 5 , 500 . 00 1 . 07 $5 , 885 f. Vehicle Rental & Fuel ' Da $ 150 . 00 2 $300 g . 8 "x11 " Photocopies Each $ 0 . 12 500 $60 h . CADD Drawings Each $3 10 $ 30 Subtotal Reimbursables $ 6 , 569 TOTAL ESTIMATED BUDGET : PHASE 02 12 353 ' In compliance with Section 112 . 061 F . S . Table 3 BUDGET ESTIMATE TITLE V PERMIT REVISION APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 3 : TITLE V RENEWAL PERMIT APLICATION ITEM BASIS RATE QUANTITY ESTIMATED COST A. 'Professional Servicesa4 a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 8 $ 19483 c . Senior Project Engineer Hr $ 163 64 $ 10 , 436 d . Project Engineer Hr $ 129 0 $0 e . Engineer Hr $ 112 84 $ 9 , 449 f. Senior Staff Engineer Hr $ 100 0 $0 g . Staff Engineer Hr $ 84 0 $ 0 Subtotal Professional Services $ 21 , 368 B. ';Technical/Administrative Services a . CADD Designer Hr $ 119 24 $2 , 865 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 16 $ 1 , 329 e . Clerical Hr $ 50 0 $ 0 Subtotal Technical/Administrative Services $42195 C. Reimbursables ' ' '� ' a . Lodging Day $ 100 0 $ 0 b . Per Diem ' Day $ 21 0 $ 0 c . Communications Fee 3 % Labor 0 . 03 $ 25 , 563 $767 d . CADD Computer System Hr $ 15 24 $360 e . Vehicle Rental & Fuel " Day $ 150 0 $0 f. 8"x11 " Photocopies Each $ 0 . 12 1000 $ 120 g . CADD Drawings Each $ 3 25 $75 Subtotal Reimbursables $ 1 , 322 TOTAL ESTIMATED BUDGET ' ; PHASE b3l - : I ` =° $26 ,885 * In compliance with Section 112 . 061 F . S . XL 11275/Budget Estimate Geosyntec Consultants Table 3 BUDGET ESTIMATE TITLE V PERMIT REVISION APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA PHASE 3 : TITLE V RENEWAL PERMIT APLICATION ITEM BASIS RATE QUANTITY ESTIMATED COST A. 'Professional Servicesa4 a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 8 $ 19483 c . Senior Project Engineer Hr $ 163 64 $ 10 , 436 d . Project Engineer Hr $ 129 0 $0 e . Engineer Hr $ 112 84 $ 9 , 449 f. Senior Staff Engineer Hr $ 100 0 $0 g . Staff Engineer Hr $ 84 0 $ 0 Subtotal Professional Services $ 21 , 368 B. ';Technical/Administrative Services a . CADD Designer Hr $ 119 24 $2 , 865 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 16 $ 1 , 329 e . Clerical Hr $ 50 0 $ 0 Subtotal Technical/Administrative Services $42195 C. Reimbursables ' ' '� ' a . Lodging Day $ 100 0 $ 0 b . Per Diem ' Day $ 21 0 $ 0 c . Communications Fee 3 % Labor 0 . 03 $ 25 , 563 $767 d . CADD Computer System Hr $ 15 24 $360 e . Vehicle Rental & Fuel " Day $ 150 0 $0 f. 8"x11 " Photocopies Each $ 0 . 12 1000 $ 120 g . CADD Drawings Each $ 3 25 $75 Subtotal Reimbursables $ 1 , 322 TOTAL ESTIMATED BUDGET ' ; PHASE b3l - : I ` =° $26 ,885 * In compliance with Section 112 . 061 F . S . XL 11275/Budget Estimate Geosyntec Consultants Table 4 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA TASK 4 : RESPONSE TO REGULATORY COMMENTS ESTIMATED ITEM BASIS RATE JQUANTITYJ COST A7 - Professional Servicesq, a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 4 $741 c . Senior Project Engineer Hr $ 163 8 $ 1 , 305 d . Project Engineer Hr $ 129 0 $ 0 e . Engineer Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 8 $ 801 g . Staff Engineer Hr I $ 84 0 $ 0 Subtotal Professional Services $ 29847 Be i, Technical/Administrative Services " a . Designer Hr $ 119 0 $ 0 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 4 $332 e . Clerical Hr $ 50 0 $ 0 Subtotal Technical/Administrative Services $332 fi C. Reimbursables a . Vehicle Rental & Fuel " Day $ 150 0 $0 b . Communications Fee 3 % Labor $ 0 . 03 $ 3 , 179 $95 c . CADD Computer System Hr $ 15 . 00 $ 0 $0 d . 8"x11 " Photocopies Each $ 0 . 12 1 50 $6 e . CADD Drawings Each $ 3 . 00 20 $60 Subtotal Reimbursables $ 161 TOTAL ESTIMATED BUDGET : PHASE 04 6 , 3 ,341 ' " In compliance with Section 112 . 061 F . S . X1. 11275/Budget Estimate Geosyntec Consultants Table 4 BUDGET ESTIMATE TION TITLE V RENEWAL PERMIT APPLI INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA Will ESTIMATED TASK 4 : RESPONSE TO REGULATORY COMMENTS RATE QUANTITY COST BAS ITEM , ll 0 $0 A. Professional Services Hr . $ 196 $741 $ 185 4 a . Principal Hr 8 $ 1 , 305 b . Associate Hr $ 163 $0 $ 129 0 c . Senior Project Engineer Hr 0 $ 0 d . Project Engineer Hr $ 112 $801 $ 100 8 e . Engineer Hr $0 $ 84 0 f . Senior Staff Engineer � I III 111Hr $2847 g . Staff Engineer Subtotal Professional Services rw . l ;. $0 13 , 1 chnical/Administrative . Technical/Administrative Services Hr $ 119 0 $0 a . Designer $ 117 0 Hr 0 $0 b . Senior Drafter/Senior CADD Operator Hr $ 81 c . Administrative Assistant $ 83 4 $ 332 Hr 0 $0 d . Technical Word Processor Hr $ 50 e . Clerical $332 Subtotal Technical/Administrative Services i°ele 77F757' f . :1110 . 777T777 7 ee') v '1 C . Reimbursable s $ 150 0 $0 Day 11 III 11 a . Vehicle Rental & Fuel ' 3% Labor $0 . 03 $3 , 179 $95 b . Communications Fee Hr $ 15 . 00 $0 $0 c . CADD Computer System Each $0 . 12 50 $6 d . 8" x11 " Photocopies Each $ 3 . 00 20 $60 e . CADD Drawings Subtotal Reimbursables $ 161 ell TOTAL ESTII lip MATED BUDGET PHASE 04 " In compliance with Section 112 . 061 F . S . Geosyntec Consultants XL11275/Budget Estimate Table 4 BUDGET ESTIMATE TITLE V RENEWAL PERMIT APPLICATION INDIAN RIVER COUNTY CLASS I LANDFILL INDIAN RIVER COUNTY , FLORIDA TASK 4 : RESPONSE TO REGULATORY COMMENTS ESTIMATED ITEM BASIS RATE JQUANTITYJ COST A7 - Professional Servicesq, a . Principal Hr $ 196 0 $0 b . Associate Hr $ 185 4 $741 c . Senior Project Engineer Hr $ 163 8 $ 1 , 305 d . Project Engineer Hr $ 129 0 $ 0 e . Engineer Hr $ 112 0 $ 0 f. Senior Staff Engineer Hr $ 100 8 $ 801 g . Staff Engineer Hr I $ 84 0 $ 0 Subtotal Professional Services $ 29847 Be i, Technical/Administrative Services " a . Designer Hr $ 119 0 $ 0 b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0 c . Administrative Assistant Hr $ 81 0 $ 0 d . Technical Word Processor Hr $ 83 4 $332 e . Clerical Hr $ 50 0 $ 0 Subtotal Technical/Administrative Services $332 fi C. Reimbursables a . Vehicle Rental & Fuel " Day $ 150 0 $0 b . Communications Fee 3 % Labor $ 0 . 03 $ 3 , 179 $95 c . CADD Computer System Hr $ 15 . 00 $ 0 $0 d . 8"x11 " Photocopies Each $ 0 . 12 1 50 $6 e . CADD Drawings Each $ 3 . 00 20 $60 Subtotal Reimbursables $ 161 TOTAL ESTIMATED BUDGET : PHASE 04 6 , 3 ,341 ' " In compliance with Section 112 . 061 F . S . X1. 11275/Budget Estimate Geosyntec Consultants