HomeMy WebLinkAbout2011-235 a �
WORK ORDER NUMBER 1
This Work Order entered into as of this 15thday of November 20 11 pursuant to that
certain Continuing Contract Agreement for Professional Services entered into as of November
15 , 2011 ( the "Agreement" ) , by and between Indian River County Solid Waste Disposal District,
a dependent special district of Indian River County , Florida ( " District" ) and Geosyntec, Inc . , a
Florida corporation ( " Consultant" ) .
The District has selected the Consultant to perform the professional services set forth on
Exhibit 1, attached to this Work Order and made part hereof by this reference . The professional
services will be performed by the Consultant for the fee schedule set forth in Exhibit 1
and
within the timeframe more particularly set forth in Exhibit 1 , all in accordance with the terms
and provisions set forth in the Agreement . Pursuant to Agreement, nothing contained in any
Work Order shall conflict with the terms of the Agreement and the terms of the Agreement
shall be deemed to be incorporated in each individual Work Order as if fully set forth herein .
IN WITNESS WHEREOF, the parties hereto have executed this Work Order as of the date first
written above .
GEOSYNTEC, INC . INDIAN RIVER COUNTY
SOLID WASTE DISPOSAL DISTRICT
1 Bob Solari , Chairman
Title : Senior Vice
_Its' . L'. l \�I1 .� I4•h4
e:oJ�t '•a�YF�� • Attest : J . K . Barton , Clerk of Court
By@ c4w�
Deputy Clerk
•�`�qy • 'f droved .
��`�RNfRCO\3 oseph A Baird, County Adm ' or
""yyyyy Ma " o•
Approved as to form and legal sufficiency
Alan S . Polackwi , Sr . , C ty Attorney
a �
WORK ORDER NUMBER 1
This Work Order entered into as of this 15thday of November 20 11 pursuant to that
certain Continuing Contract Agreement for Professional Services entered into as of November
15 , 2011 ( the "Agreement" ) , by and between Indian River County Solid Waste Disposal District,
a dependent special district of Indian River County , Florida ( " District" ) and Geosyntec, Inc . , a
Florida corporation ( " Consultant" ) .
The District has selected the Consultant to perform the professional services set forth on
Exhibit 1, attached to this Work Order and made part hereof by this reference . The professional
services will be performed by the Consultant for the fee schedule set forth in Exhibit 1
and
within the timeframe more particularly set forth in Exhibit 1 , all in accordance with the terms
and provisions set forth in the Agreement . Pursuant to Agreement, nothing contained in any
Work Order shall conflict with the terms of the Agreement and the terms of the Agreement
shall be deemed to be incorporated in each individual Work Order as if fully set forth herein .
IN WITNESS WHEREOF, the parties hereto have executed this Work Order as of the date first
written above .
GEOSYNTEC, INC . INDIAN RIVER COUNTY
SOLID WASTE DISPOSAL DISTRICT
1 Bob Solari , Chairman
Title : Senior Vice
_Its' . L'. l \�I1 .� I4•h4
e:oJ�t '•a�YF�� • Attest : J . K . Barton , Clerk of Court
By@ c4w�
Deputy Clerk
•�`�qy • 'f droved .
��`�RNfRCO\3 oseph A Baird, County Adm ' or
""yyyyy Ma " o•
Approved as to form and legal sufficiency
Alan S . Polackwi , Sr . , C ty Attorney
EXHIBIT 1
PROFESSIONAL SERVICES
enghieers I st ieritists I innowltors
EXHIBIT 1
PROFESSIONAL SERVICES
enghieers I st ieritists I innowltors
710
Geosyntec ' 1200 Riverplace Boulevard, Suite 207�/' Jacksonville, Florida 32207
PH 904. 858 . 1818
consultants FAX 904 . 396 . 1143
www. geosyntee.corn
3 November 2011
Mr . Himanshu Mehta, P . E . , Managing Director
Solid Waste Disposal District
Indian River County
1325 74th Avenue SW
Vero Beach , Florida 32968
Subject : Proposal for Engineering Services
Title V Air Operation Permit Renewal Application
Indian River County Landfill Facility
Vero Beach , Indian River County , Florida
Dear Mr. Himanshu
Geosyntec Consultants , Inc . (Geosyntec ) is pleased to submit this proposal to Indian River
County ( IRC) , Solid Waste Disposal District ( SWDD) to provide engineering services related to
the renewal of the five - year Title V Air Operation Permit for the IRC Landfill ( IRCL) facility .
The current 5 -year permit will expire on June 30 , 2012 with the renewal application due
on
December 31 , 2011 . The proposal presents the scope of work, schedule, and budget estimate for
the preparation and submittal to the Florida Department of Environmental Protection (FDEP) the
application for the renewal permit, including Tier 2 testing and analysis to estimate the annual
quantity of nonmethane organic compounds (NMOC) emissions from the IRC Class I landfill ,
and responding to any requests for additional information ( RAIs) by the FDEP . The proposal
was prepared in response to a verbal request from Mr . Himanshu Mehta, P . E . , Managing
Director, of SWDD , during a 2 November 2011 telephone conversation with Dr. Kwasi Badu-
Tweneboah , P . E . of Geosyntec .
Geosyntec has prepared this proposal as Exhibit I to Work Order No . 1 for the Continuing
Contract Agreement for Professional Services between IRC SWDD and Geosyntec , dated 15
November 2011 . The remainder of this proposal presents : (i ) project background ; ( ii) proposed
scope of work ; ( iii ) schedule ; and ( iv ) budget estimate .
PROJECT BACKGROUND
The IRCL facility is located in southern Indian River County, east of Interstate 95 , south of Oslo
Road , and west of Rangeline Road in Vero Beach , Florida. The landfill serves the unincorporated
Indian River County and municipalities of Vero Beach , Orchid , Fellsmere , Sebastian , and Indian
River Shores . The SWDD administers the management and operation of the Class I landfill at the
IRCL facility, and as such , it is the permit holder of the IRCL facility .
NCP201 I \XL I 1275\J L I 1126_Title V Proposal . doc
engineers I Sc' ielltists I innovators
710
Geosyntec ' 1200 Riverplace Boulevard, Suite 207�/' Jacksonville, Florida 32207
PH 904. 858 . 1818
consultants FAX 904 . 396 . 1143
www. geosyntee.corn
3 November 2011
Mr . Himanshu Mehta, P . E . , Managing Director
Solid Waste Disposal District
Indian River County
1325 74th Avenue SW
Vero Beach , Florida 32968
Subject : Proposal for Engineering Services
Title V Air Operation Permit Renewal Application
Indian River County Landfill Facility
Vero Beach , Indian River County , Florida
Dear Mr. Himanshu
Geosyntec Consultants , Inc . (Geosyntec ) is pleased to submit this proposal to Indian River
County ( IRC) , Solid Waste Disposal District ( SWDD) to provide engineering services related to
the renewal of the five - year Title V Air Operation Permit for the IRC Landfill ( IRCL) facility .
The current 5 -year permit will expire on June 30 , 2012 with the renewal application due
on
December 31 , 2011 . The proposal presents the scope of work, schedule, and budget estimate for
the preparation and submittal to the Florida Department of Environmental Protection (FDEP) the
application for the renewal permit, including Tier 2 testing and analysis to estimate the annual
quantity of nonmethane organic compounds (NMOC) emissions from the IRC Class I landfill ,
and responding to any requests for additional information ( RAIs) by the FDEP . The proposal
was prepared in response to a verbal request from Mr . Himanshu Mehta, P . E . , Managing
Director, of SWDD , during a 2 November 2011 telephone conversation with Dr. Kwasi Badu-
Tweneboah , P . E . of Geosyntec .
Geosyntec has prepared this proposal as Exhibit I to Work Order No . 1 for the Continuing
Contract Agreement for Professional Services between IRC SWDD and Geosyntec , dated 15
November 2011 . The remainder of this proposal presents : (i ) project background ; ( ii) proposed
scope of work ; ( iii ) schedule ; and ( iv ) budget estimate .
PROJECT BACKGROUND
The IRCL facility is located in southern Indian River County, east of Interstate 95 , south of Oslo
Road , and west of Rangeline Road in Vero Beach , Florida. The landfill serves the unincorporated
Indian River County and municipalities of Vero Beach , Orchid , Fellsmere , Sebastian , and Indian
River Shores . The SWDD administers the management and operation of the Class I landfill at the
IRCL facility, and as such , it is the permit holder of the IRCL facility .
NCP201 I \XL I 1275\J L I 1126_Title V Proposal . doc
engineers I Sc' ielltists I innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 2
This landfill facility is currently operating under Title V Air Operation Permit No . 0610015 - 003 -
AV , effective July 19 , 2007 . The existing Class I Landfill has a voluntarily- installed gas
collection and control system (GCCS ) for those areas at final grades . Segment 1 , Segment 2 , and
the Infill Area of the IRCL have an existing GCCS that consists of vertical and horizontal gas
extraction wells , gas collection lateral and header pipes, blower, and flare . Collected landfill gas
is piped to a flare/blower system , located immediately east of Segment 2 , where the combustible
components are oxidized by incineration . SWDD has recently entered into an agreement for the
sale of the landfill gas to an adjacent waste4o- ethanol facility , presently under construction , for
use as a supplemental fuel for the process .
Geosyntec also understands that the IRCL facility is currently regulated under the New Source
Performance Standards (NSPS ) for municipal solid waste ( MSW) landfills as identified in
Subpart WWW of 40 CFR, Part 60 ( Subpart WWW) . An NSPS Tier 2 NMOC emissions rate
report was prepared and submitted to FDEP as part of the Title V renewal permit application in
January 2007 . A similar Tier 2 testing will be performed to estimate the site - specific NMOC
concentration to recalculate and submit a Tier 2 NMOC emission rate report as part of this 2011
Title V renewal permit application .
PROPOSED SCOPE OF WORK
This project includes professional engineering services required to renew the Title V Air
Operation Permit for the IRCL facility . The scope of work is based on the requirements of
Chapter 403 , Florida Statue ( F . S .) , Florida Administrative Code (F . A . C .) Chapters 624 , 62-210
and 62 -213 ) , and Geosyntec ' s understanding of the project based on information provided by
SWDD . Geosyntec will provide all engineering services necessary to prepare the 5 - year renewal
permit application , including sampling and testing the landfill gas to calculate the NMOC , and
address any request for additional information ( RAI ) from FDEP .
For budgeting purposes , the scope of work will be performed in four phases as follows :
• Phase 1 — General Consulting/Meeting Support/ Project Management ;
• Phase 2 — Tier 2 Testing and Reporting ;
• Phase 3 — Title V Renewal Permit Application ; and
• Phase 4 — Response to Regulatory Comments .
Each of these phases is briefly described below .
NCP201IAL11275UL1 1126 Title V Proposal . doc
enI lteryrs ( ti : ixl � titti I innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 2
This landfill facility is currently operating under Title V Air Operation Permit No . 0610015 - 003 -
AV , effective July 19 , 2007 . The existing Class I Landfill has a voluntarily- installed gas
collection and control system (GCCS ) for those areas at final grades . Segment 1 , Segment 2 , and
the Infill Area of the IRCL have an existing GCCS that consists of vertical and horizontal gas
extraction wells , gas collection lateral and header pipes, blower, and flare . Collected landfill gas
is piped to a flare/blower system , located immediately east of Segment 2 , where the combustible
components are oxidized by incineration . SWDD has recently entered into an agreement for the
sale of the landfill gas to an adjacent waste4o- ethanol facility , presently under construction , for
use as a supplemental fuel for the process .
Geosyntec also understands that the IRCL facility is currently regulated under the New Source
Performance Standards (NSPS ) for municipal solid waste ( MSW) landfills as identified in
Subpart WWW of 40 CFR, Part 60 ( Subpart WWW) . An NSPS Tier 2 NMOC emissions rate
report was prepared and submitted to FDEP as part of the Title V renewal permit application in
January 2007 . A similar Tier 2 testing will be performed to estimate the site - specific NMOC
concentration to recalculate and submit a Tier 2 NMOC emission rate report as part of this 2011
Title V renewal permit application .
PROPOSED SCOPE OF WORK
This project includes professional engineering services required to renew the Title V Air
Operation Permit for the IRCL facility . The scope of work is based on the requirements of
Chapter 403 , Florida Statue ( F . S .) , Florida Administrative Code (F . A . C .) Chapters 624 , 62-210
and 62 -213 ) , and Geosyntec ' s understanding of the project based on information provided by
SWDD . Geosyntec will provide all engineering services necessary to prepare the 5 - year renewal
permit application , including sampling and testing the landfill gas to calculate the NMOC , and
address any request for additional information ( RAI ) from FDEP .
For budgeting purposes , the scope of work will be performed in four phases as follows :
• Phase 1 — General Consulting/Meeting Support/ Project Management ;
• Phase 2 — Tier 2 Testing and Reporting ;
• Phase 3 — Title V Renewal Permit Application ; and
• Phase 4 — Response to Regulatory Comments .
Each of these phases is briefly described below .
NCP201IAL11275UL1 1126 Title V Proposal . doc
enI lteryrs ( ti : ixl � titti I innovators
Mr. Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 3
Phase 1 — General Consulting/Meeting Support/Project Management
Under this phase , Geosyntec will perform project planning and management responsibilities,
such as correspondence with SWDD and FDEP, invoice review , project coordination, budget and
schedule tracking and project administration . Geosyntec has also included a budget for
preparation and attendance (by two Geosyntec personnel ) at two meetings : (i ) kickoff meeting
with SWDD staff to obtain information required to complete the application ; and (ii ) a meeting
with FDEP and SWDD to present the complete application and respond to questions .
Phase 2 —Tier 2 Testing and Reporting
The scope of the Tier 2 testing and reporting phase includes the development of a test plan , field
gas sampling, laboratory analysis, data evaluation , and reporting . We will collect gas samples
from the existing gas collection system at a location prior to the flare station ' s
blower and
condensate knockout . Three samples will be collected in passivated SUMMA canisters and sent
under chain - of- custody protocol to an analytical laboratory for testing . Samples will be analyzed
for nitrogen by EPA Method 3C to validate the sample ( i . e . , confirm minimal air intrusion
occurred ) . Upon sample validation , the samples will be analyzed for NMOCs by EPA Method
25C . Sample collection and analysis will be performed by TRC Environmental Corporation ,
Gainesville , Florida (TRC ) as a subcontractor to Geosyntec . A copy of TRC ' s proposal is
included as Attachment A .
Geosyntec will review the analytical results , estimate annual NMOC mass emission rates, and
prepare an NSPS Tier 2 NMOC emissions rate report that summarizes sampling and analysis
activities and results . Data analysis will include the calculation of NMOC concentrations based
on laboratory analysis and waste acceptance rates . Geosyntec will use the EPA ' s Landfill Gas
Emissions Model Version 3 . 02 to estimate the NMOC emission rate . Results and conclusions
regarding the need for compliance with the additional NSPS monitoring and reporting
requirements of the Class I landfill will be based on the regulatory threshold of 50 Mg/yr of
NMOC generation .
Phase 3 — Title V Renewal Permit Application
Geosyntec will prepare the FDEP Title V Air Operation renewal permit application for the IRC
landfill . Geosyntec will complete FDEP, Division of Air Resource Management Form No . 62 -
210 . 900 ( 1 ) titled "Application for Air Permit - Long Form " and address the additional
information items required by the form . The following activities will be performed to prepare
the renewal permit application :
NCP201 I \XL11275\JLl 1126 Title V Proposal . doc
engineers P Scientists I innovators
Mr. Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 3
Phase 1 — General Consulting/Meeting Support/Project Management
Under this phase , Geosyntec will perform project planning and management responsibilities,
such as correspondence with SWDD and FDEP, invoice review , project coordination, budget and
schedule tracking and project administration . Geosyntec has also included a budget for
preparation and attendance (by two Geosyntec personnel ) at two meetings : (i ) kickoff meeting
with SWDD staff to obtain information required to complete the application ; and (ii ) a meeting
with FDEP and SWDD to present the complete application and respond to questions .
Phase 2 —Tier 2 Testing and Reporting
The scope of the Tier 2 testing and reporting phase includes the development of a test plan , field
gas sampling, laboratory analysis, data evaluation , and reporting . We will collect gas samples
from the existing gas collection system at a location prior to the flare station ' s
blower and
condensate knockout . Three samples will be collected in passivated SUMMA canisters and sent
under chain - of- custody protocol to an analytical laboratory for testing . Samples will be analyzed
for nitrogen by EPA Method 3C to validate the sample ( i . e . , confirm minimal air intrusion
occurred ) . Upon sample validation , the samples will be analyzed for NMOCs by EPA Method
25C . Sample collection and analysis will be performed by TRC Environmental Corporation ,
Gainesville , Florida (TRC ) as a subcontractor to Geosyntec . A copy of TRC ' s proposal is
included as Attachment A .
Geosyntec will review the analytical results , estimate annual NMOC mass emission rates, and
prepare an NSPS Tier 2 NMOC emissions rate report that summarizes sampling and analysis
activities and results . Data analysis will include the calculation of NMOC concentrations based
on laboratory analysis and waste acceptance rates . Geosyntec will use the EPA ' s Landfill Gas
Emissions Model Version 3 . 02 to estimate the NMOC emission rate . Results and conclusions
regarding the need for compliance with the additional NSPS monitoring and reporting
requirements of the Class I landfill will be based on the regulatory threshold of 50 Mg/yr of
NMOC generation .
Phase 3 — Title V Renewal Permit Application
Geosyntec will prepare the FDEP Title V Air Operation renewal permit application for the IRC
landfill . Geosyntec will complete FDEP, Division of Air Resource Management Form No . 62 -
210 . 900 ( 1 ) titled "Application for Air Permit - Long Form " and address the additional
information items required by the form . The following activities will be performed to prepare
the renewal permit application :
NCP201 I \XL11275\JLl 1126 Title V Proposal . doc
engineers P Scientists I innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 4
• Facility plot plan ;
• Process flow diagram ;
• Precautions to prevent emissions of unconfined particulate matter;
• List of insignificant activities ;
• Identification of applicable requirements ;
• Compliance report and plan
• changes to current Title V Air Operation Permit ;
• Fuel analysis or specification ;
• Detailed description of control equipment;
• Procedures for startup and shutdown ;
• Operation and maintenance plan ;
• Previously submitted information ; and
• Identification of applicable requirements
Geosyntec will describe the existing emission control system for IRCL facility , and calculate the
emissions of air pollutants expected to be released into the environment by its operation .
Geosyntec will complete the required FDEP Form 62 -210 . 900( 1 ) , and prepare a transmittal letter
to FDEP that summarizes the renewal permit application package .
Phase 4 — Response to Regulatory Comments
Following submittal of the Renewal Permit Application , Geosyntec will meet with Central
District office of the FDEP Air Resource Management Division to present and discuss the
application package . Geosyntec will provide FDEP with written responses to RAIs throughout
the course of the permit application review process . For the purpose of the budget estimate,
Geosyntec has estimated one response to FDEP RAI will be required .
SCHEDULE
Geosyntec will initiate work immediately upon receipt of Notice to Proceed (NTP) from SWDD .
Geosyntec has assumed that this NTP would be issued no later than 16 November 2011 in order
NCP2011 \XL11275\JLI I126_Tide V Proposal . doc
engineers I scientists 1 innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 4
• Facility plot plan ;
• Process flow diagram ;
• Precautions to prevent emissions of unconfined particulate matter;
• List of insignificant activities ;
• Identification of applicable requirements ;
• Compliance report and plan
• changes to current Title V Air Operation Permit ;
• Fuel analysis or specification ;
• Detailed description of control equipment;
• Procedures for startup and shutdown ;
• Operation and maintenance plan ;
• Previously submitted information ; and
• Identification of applicable requirements
Geosyntec will describe the existing emission control system for IRCL facility , and calculate the
emissions of air pollutants expected to be released into the environment by its operation .
Geosyntec will complete the required FDEP Form 62 -210 . 900( 1 ) , and prepare a transmittal letter
to FDEP that summarizes the renewal permit application package .
Phase 4 — Response to Regulatory Comments
Following submittal of the Renewal Permit Application , Geosyntec will meet with Central
District office of the FDEP Air Resource Management Division to present and discuss the
application package . Geosyntec will provide FDEP with written responses to RAIs throughout
the course of the permit application review process . For the purpose of the budget estimate,
Geosyntec has estimated one response to FDEP RAI will be required .
SCHEDULE
Geosyntec will initiate work immediately upon receipt of Notice to Proceed (NTP) from SWDD .
Geosyntec has assumed that this NTP would be issued no later than 16 November 2011 in order
NCP2011 \XL11275\JLI I126_Tide V Proposal . doc
engineers I scientists 1 innovators
ATTACHMENT A
TIER 2 TESTING PROPOSAL
engineers I scientists I innovators
ATTACHMENT A
TIER 2 TESTING PROPOSAL
engineers I scientists I innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 5
for us to complete the work and submit the Title V Air Operation Renewal Permit Application to
FDEP before the deadline of December 31 , 2011 .
BUDGET ESTIMATE
A budget estimate for the scope of work outlined in this proposal is summarized in the following
table , and a detailed budget estimate is provided as Attachment B . Note that the budget estimate
for Phase 2 includes TRC ' s fees for collecting the samples and testing . The budget estimate does
not include permit fees that will be required at the time the permit application is submitted to
FDEP .
Phase 1 — General Consulting/Meeting Support/Project Management $ 99523
Phase 2 — Tier 2 Testing and Reporting $ 12 , 353
Phase 3 — Title V Renewal Permit Application $26 , 885
Phase 4 : Response to Regulatory Comments 3 341
Total Budget Estimate $ 529101
Geosyntec will not exceed the cost estimate without prior approval and written authorization
from SWDD .
CLOSURE
Geosyntec appreciates this opportunity to offer our services . If this proposal is acceptable ,
please indicate your agreement by signing the attached work authorization , which references this
proposal . Please return one signed work authorization to Dr . Badu -Tweneboah ' s attention .
Please call the undersigned with questions you may have as you review this proposal .
Sincerelv .
Tanhum Goldshmid , Ph . D .
Senior Consultant
Kwasi Badu -Tweneboah , Ph . D . , P . E .
Associate
Attachments
NCP201IALI 1275\JLI I126_Title V Proposal . doc
engineers I scientists I innovators
Mr . Himanshu Mehta, P . E . Managing Director
3 November 2011
Page 5
for us to complete the work and submit the Title V Air Operation Renewal Permit Application to
FDEP before the deadline of December 31 , 2011 .
BUDGET ESTIMATE
A budget estimate for the scope of work outlined in this proposal is summarized in the following
table , and a detailed budget estimate is provided as Attachment B . Note that the budget estimate
for Phase 2 includes TRC ' s fees for collecting the samples and testing . The budget estimate does
not include permit fees that will be required at the time the permit application is submitted to
FDEP .
Phase 1 — General Consulting/Meeting Support/Project Management $ 99523
Phase 2 — Tier 2 Testing and Reporting $ 12 , 353
Phase 3 — Title V Renewal Permit Application $26 , 885
Phase 4 : Response to Regulatory Comments 3 341
Total Budget Estimate $ 529101
Geosyntec will not exceed the cost estimate without prior approval and written authorization
from SWDD .
CLOSURE
Geosyntec appreciates this opportunity to offer our services . If this proposal is acceptable ,
please indicate your agreement by signing the attached work authorization , which references this
proposal . Please return one signed work authorization to Dr . Badu -Tweneboah ' s attention .
Please call the undersigned with questions you may have as you review this proposal .
Sincerelv .
Tanhum Goldshmid , Ph . D .
Senior Consultant
Kwasi Badu -Tweneboah , Ph . D . , P . E .
Associate
Attachments
NCP201IALI 1275\JLI I126_Title V Proposal . doc
engineers I scientists I innovators
6322 NW 18th Drive
Suite 170
Gainesville , FL 32653
352 . 378 . 0332 PHONE
352 . 378 . 0354 FAX
www. TRCsolutions . com
Submitted via e-mail
KBaduTweneboah (& Geosyn tec. com
November 3 , 2011
Mr. Kwasi Badu-Tweneboah, Ph . D . , P . E.
Geosyntec Consultants
120o Riverplace Boulevard, Suit 710
Jacksonville, Florida 32207
Re : TRC Proposal No . 188759 . 999o . 0000
Tier II Sampling Project — Lake County Landfill
Dear Mr. Badu-Tweneboah,
I
I
TRC Environmental Corporation , Gainesville Office (TRC) is pleased to submit this
proposal to Geosyntec Consultants (Geosyntec) to conduct landfill gas Tier II sampling
at a municipal solid waste (MSW) landfill in Vero Beach, Indian River County, Florida.
We believe that with 15 years of landfill gas Tier II testing experience and our long
standing reputation of providing quality work to clients, that TRC is the best choice for
providing your Tier II landfill gas emission services . j
Test Program Scope of Work
I
TRC will provide the labor, equipment, and technical expertise required to conduct your
testing program as outlined below. The testing will be conducted at a landfill located in f
Indian River County by an Associate Project Manager . The actual mobilization, testing
and equipment set-up and sampling, and demobilization will be conducted over a one day
schedule. All testing shall be conducted in one mobilization .
w
The actual scope of work is to consist of the collection of landfill gas samples from the I
common header at a location prior to any condensate removal system at the Indian River
Landfil . Samples will be collected into 6 or 8 liter SUMMA passivated canisters (supplied
by an analytical laboratory) , pre-charged halfway with Helium, in accordance with EPA
Method 25C protocols . A total of three samples shall be collected over a 20 minute sample
1
I
^ 1 �
I
6322 NW 18th Drive
Suite 170
Gainesville , FL 32653
352 . 378 . 0332 PHONE
352 . 378 . 0354 FAX
www. TRCsolutions . com
Submitted via e-mail
KBaduTweneboah (& Geosyn tec. com
November 3 , 2011
Mr. Kwasi Badu-Tweneboah, Ph . D . , P . E.
Geosyntec Consultants
120o Riverplace Boulevard, Suit 710
Jacksonville, Florida 32207
Re : TRC Proposal No . 188759 . 999o . 0000
Tier II Sampling Project — Lake County Landfill
Dear Mr. Badu-Tweneboah,
I
I
TRC Environmental Corporation , Gainesville Office (TRC) is pleased to submit this
proposal to Geosyntec Consultants (Geosyntec) to conduct landfill gas Tier II sampling
at a municipal solid waste (MSW) landfill in Vero Beach, Indian River County, Florida.
We believe that with 15 years of landfill gas Tier II testing experience and our long
standing reputation of providing quality work to clients, that TRC is the best choice for
providing your Tier II landfill gas emission services . j
Test Program Scope of Work
I
TRC will provide the labor, equipment, and technical expertise required to conduct your
testing program as outlined below. The testing will be conducted at a landfill located in f
Indian River County by an Associate Project Manager . The actual mobilization, testing
and equipment set-up and sampling, and demobilization will be conducted over a one day
schedule. All testing shall be conducted in one mobilization .
w
The actual scope of work is to consist of the collection of landfill gas samples from the I
common header at a location prior to any condensate removal system at the Indian River
Landfil . Samples will be collected into 6 or 8 liter SUMMA passivated canisters (supplied
by an analytical laboratory) , pre-charged halfway with Helium, in accordance with EPA
Method 25C protocols . A total of three samples shall be collected over a 20 minute sample
1
I
^ 1 �
I
i
i
Mr. Kwasi Badu-Tweneboah November 3 , 2011
Geosyntec Consultants
i
i
period per canister. The budget includes shipment of samples to and from an analytical
laboratory (2 day air with tracking labels) for analysis via EPA Methods 3C and 25C.
Geosyntec or the landfill owner shall supply a landfill gas analyzer to purge the sampling
system and verify the validity of the landfill gas (must contain less than 5% oxygen) just
prior to sample collection .
i
Deliverables
TRC will submit a draft copy of the test report within ten ( 10 ) business days of the
completion of the sampling program . The final report (up to 6 copies) shall be
submitted within five (5) business days of receiving client comments . Final reports will
include an introduction, summary of results, process description, description of all test
and analytical methodologies, quality assurance and quality control measures and
results , and copies of the analytical data .
Program Price
TRC proposes to perform the sampling program described above on a Fixed Price Basis
in accordance with the terms and conditions noted in Table 1 . The cost for each of the
testing options is shown in the following table .
TABLE 1 — TESTING COSTS
pyx �( �F i
"VI 7 � � k � � E �,i� � t 1x � QM
r, < 5 . ,, , . -. _ ,. .,r r e q °(= c x.p. � . .,. mc�E , a, � �e, i.tx MIS �. r{ 4� �,u �� � �.,�+
o-'£ � �� •� _'
Base Price — Testing per Scope $ 4,776
TRC Supplies LFG Analyzer with
Add $475
built in pump for testing
Client Delays/Added Testing See Below
f
These costs include all mobilization, travel , and per diem costs for the test team . If delays
are encountered, or if additional out- of-scope testing is performed at the request of
Geosyntec, the costs for additional time on-site over the hours per day specified in this
proposal will be charged at a rate of $ 8o per hour per person. If additional night layovers
are required a $ 150 per diem per person will be charged. Work performed over 12-hours 1
per day or on weekends shall be charged at overtime rates of $ 120 . 00 per person .
� 2 �
I
i
i
Mr. Kwasi Badu-Tweneboah November 3 , 2011
Geosyntec Consultants
i
i
period per canister. The budget includes shipment of samples to and from an analytical
laboratory (2 day air with tracking labels) for analysis via EPA Methods 3C and 25C.
Geosyntec or the landfill owner shall supply a landfill gas analyzer to purge the sampling
system and verify the validity of the landfill gas (must contain less than 5% oxygen) just
prior to sample collection .
i
Deliverables
TRC will submit a draft copy of the test report within ten ( 10 ) business days of the
completion of the sampling program . The final report (up to 6 copies) shall be
submitted within five (5) business days of receiving client comments . Final reports will
include an introduction, summary of results, process description, description of all test
and analytical methodologies, quality assurance and quality control measures and
results , and copies of the analytical data .
Program Price
TRC proposes to perform the sampling program described above on a Fixed Price Basis
in accordance with the terms and conditions noted in Table 1 . The cost for each of the
testing options is shown in the following table .
TABLE 1 — TESTING COSTS
pyx �( �F i
"VI 7 � � k � � E �,i� � t 1x � QM
r, < 5 . ,, , . -. _ ,. .,r r e q °(= c x.p. � . .,. mc�E , a, � �e, i.tx MIS �. r{ 4� �,u �� � �.,�+
o-'£ � �� •� _'
Base Price — Testing per Scope $ 4,776
TRC Supplies LFG Analyzer with
Add $475
built in pump for testing
Client Delays/Added Testing See Below
f
These costs include all mobilization, travel , and per diem costs for the test team . If delays
are encountered, or if additional out- of-scope testing is performed at the request of
Geosyntec, the costs for additional time on-site over the hours per day specified in this
proposal will be charged at a rate of $ 8o per hour per person. If additional night layovers
are required a $ 150 per diem per person will be charged. Work performed over 12-hours 1
per day or on weekends shall be charged at overtime rates of $ 120 . 00 per person .
� 2 �
I
A
I
Mr. Kwasi Badu-Tweneboah November 3 , 2011 I
Geosyntee Consultants
I
Items Supplied by Client
I
The cost of this proposal is based on the client providing the following items in order to
complete the sampling program .
i
i . The proposal cost is based on the facility providing safe access for the test crew to all
of the sampling locations, including vehicular access .
2 . The client shall verify the sampling site location and confirm that there is a sample
port located on the common header prior to the condensate removal system .
3 . If there is not a sampling location, then the client shall install a sampling location
prior to TRC mobilization .
4 . The landfill shall additionally supply a portable landfill gas analyzer equipped with a
sample pump to purge the sample train and verify the quality of the landfill gas prior to
filling the sample canisters .
Completion Schedule
i
The final schedule will be confirmed upon project award.
Proposal Period l
The detailed cost presented in this proposal is valid for go days from the date on the cover
page of this proposal ( November 3 , 2011) .
Invoice Terms i
TRC will submit a single lump sum invoice upon completion of the field sampling.
Payment terms are net 3o days . i
You may engage our services by signing and returning the authorization form
(Attachment A) attached to this letter. Alternatively, you may issue a purchase order or
contract that references TRC Proposal No . 188759 . 9990 . 000o dated November 3 , 2011 .
TRC appreciates this opportunity to provide Geosyntec with this proposal . We are looking
forward to providing you with our emissions testing services . If you have any questions f
regarding this proposal or need changes and/or modifications to the sampling program,
please contact me at (352) 378 - 0332 (Office) , (352) 317- 0041 (Cellular) or
lbrenner (@tresolutions . com .
3
A
I
Mr. Kwasi Badu-Tweneboah November 3 , 2011 I
Geosyntee Consultants
I
Items Supplied by Client
I
The cost of this proposal is based on the client providing the following items in order to
complete the sampling program .
i
i . The proposal cost is based on the facility providing safe access for the test crew to all
of the sampling locations, including vehicular access .
2 . The client shall verify the sampling site location and confirm that there is a sample
port located on the common header prior to the condensate removal system .
3 . If there is not a sampling location, then the client shall install a sampling location
prior to TRC mobilization .
4 . The landfill shall additionally supply a portable landfill gas analyzer equipped with a
sample pump to purge the sample train and verify the quality of the landfill gas prior to
filling the sample canisters .
Completion Schedule
i
The final schedule will be confirmed upon project award.
Proposal Period l
The detailed cost presented in this proposal is valid for go days from the date on the cover
page of this proposal ( November 3 , 2011) .
Invoice Terms i
TRC will submit a single lump sum invoice upon completion of the field sampling.
Payment terms are net 3o days . i
You may engage our services by signing and returning the authorization form
(Attachment A) attached to this letter. Alternatively, you may issue a purchase order or
contract that references TRC Proposal No . 188759 . 9990 . 000o dated November 3 , 2011 .
TRC appreciates this opportunity to provide Geosyntec with this proposal . We are looking
forward to providing you with our emissions testing services . If you have any questions f
regarding this proposal or need changes and/or modifications to the sampling program,
please contact me at (352) 378 - 0332 (Office) , (352) 317- 0041 (Cellular) or
lbrenner (@tresolutions . com .
3
Mr . Kwasi Badu-Tweneboah November 3 , 2011
Geosyntec Consultants
Sincerely,
i
L onard Bren r,
Senior Project Manager
TRC
i
Air Measurements — Gainesville Office
6322 NW 18th Drive , Suite 170 {
Gainesville , Florida32653
(352) 378 - 0332 Office
(352) 378 - 0354 Facsimile I
(352 ) 317- 0041 Cellular
Email : lbrenner0tresolutions . com
I
E
I
G
I
i
I
I
I
r
I
I
Mr . Kwasi Badu-Tweneboah November 3 , 2011
Geosyntec Consultants
Sincerely,
i
L onard Bren r,
Senior Project Manager
TRC
i
Air Measurements — Gainesville Office
6322 NW 18th Drive , Suite 170 {
Gainesville , Florida32653
(352) 378 - 0332 Office
(352) 378 - 0354 Facsimile I
(352 ) 317- 0041 Cellular
Email : lbrenner0tresolutions . com
I
E
I
G
I
i
I
I
I
r
I
I
i
I
i
i
ATTACHMENT A
AUTHORIZATION TO PROCEED
i
I
I
I accept the fee structure and the terms and conditions of TRC Proposal No .
i88759 . 9990 . 000o dated November 3 , 2011 authorize TRC to proceed with this project.
GEOSYNTEC CONSULTANTS
i
Company Name i
Company Representative
Title
Signature Date
E
I
1
i
i
i
i
I
i
i
ATTACHMENT A
AUTHORIZATION TO PROCEED
i
I
I
I accept the fee structure and the terms and conditions of TRC Proposal No .
i88759 . 9990 . 000o dated November 3 , 2011 authorize TRC to proceed with this project.
GEOSYNTEC CONSULTANTS
i
Company Name i
Company Representative
Title
Signature Date
E
I
1
i
i
i
ATTACHMENT B
DETAILED BUDGET ESTIMATE
engineers I scientists I innovators
ATTACHMENT B
DETAILED BUDGET ESTIMATE
engineers I scientists I innovators
Table 1
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 1 : PROJECT MANAGEMENT/ MEETINGS
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. Professional Services
a . Principal Hr $ 196 0 $ 0
b . Associate Hr $ 185 24 $4 , 448
c . Senior Project Engineer Hr $ 163 24 $ 3 , 914
d . Project Engineer Hr $ 129 1 0 $ 0
e . Engineer Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 0 $ 0
g . Staff Engineer Hr $ 84 0 $ 0
Subtotal Professional Services $ 8 , 361
B. Technical/Administrative Services
a . CADD Designer Hr $ 119 0 $ 0
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 4 $ 332
e . Clerical Hr $ 50 1 4 $200
Subtotal Technical/Administrative Services $ 532
C . `' Reimbursables
a . Lodging Day $ 100 0 $ 0
b . Per Diem ` Day $21 0 $ 0
c . Communications Fee 3 % Labor 0 . 03 $ 8 , 894 $267
d . CADD Computer System Hr $ 15 2 $ 30
e . Vehicle Rental & Fuel ` Day $ 150 2 $ 300
f. 8"x11 " Photocopies Each $ 0 . 12 25 $ 3
g . CADD Drawings Each $ 3 10 $ 30
Subtotal Reimbursables $ 630
TOTAL ESTIMATED BUDGET : 'PHASE 01 $9 523
* In compliance with Section 112 . 061 F . S .
XL11275/Budget Estimate Geosyntec Consultants
Table 1
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 1 : PROJECT MANAGEMENT/ MEETINGS
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. Professional Services
a . Principal Hr $ 196 0 $ 0
b . Associate Hr $ 185 24 $4 , 448
c . Senior Project Engineer Hr $ 163 24 $ 3 , 914
d . Project Engineer Hr $ 129 1 0 $ 0
e . Engineer Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 0 $ 0
g . Staff Engineer Hr $ 84 0 $ 0
Subtotal Professional Services $ 8 , 361
B. Technical/Administrative Services
a . CADD Designer Hr $ 119 0 $ 0
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 4 $ 332
e . Clerical Hr $ 50 1 4 $200
Subtotal Technical/Administrative Services $ 532
C . `' Reimbursables
a . Lodging Day $ 100 0 $ 0
b . Per Diem ` Day $21 0 $ 0
c . Communications Fee 3 % Labor 0 . 03 $ 8 , 894 $267
d . CADD Computer System Hr $ 15 2 $ 30
e . Vehicle Rental & Fuel ` Day $ 150 2 $ 300
f. 8"x11 " Photocopies Each $ 0 . 12 25 $ 3
g . CADD Drawings Each $ 3 10 $ 30
Subtotal Reimbursables $ 630
TOTAL ESTIMATED BUDGET : 'PHASE 01 $9 523
* In compliance with Section 112 . 061 F . S .
XL11275/Budget Estimate Geosyntec Consultants
Table 2
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 2 : Tier 2 Testing & Reporting
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. Professional Services
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 4 $740
c . Senior Project Engineer Hr $ 163 8 $ 1 , 304
d . Project Engineer Hr $ 129 0 $ 0
e . Engineer -- Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 16 $ 1 , 600
g . Staff Engineer Hr $84 0 $0
Subtotal Professional Services $3 , 644
B. Technical/Administrative Services
a . CADD Designer Hr $ 119 8 $952
b . Drafter/CADD Operator/Artist Hr $ 117 0 $ 0
c . Technical/Administrative Assistant Hr $ 81 4 $ 324
d . Technical Word Processor Hr $ 83 8 $664
e . Clerical Hr $ 50 4 $200
Subtotal Technical/Administrative Services $2 , 140
Cm Reimbursables
a . Lodging Da $ 75 0 $ 0
b . Per Diem ' Da $21 0 $0
c . Communications Fee 3 % Labor 0 . 03 $ 5 , 784 $ 174
d . CADD Computer System Hr $ 15 8 $ 120
e . Sampling & Testing Subcontractor Est $ 5 , 500 . 00 1 . 07 $5 , 885
f. Vehicle Rental & Fuel ' Da $ 150 . 00 2 $300
g . 8 "x11 " Photocopies Each $ 0 . 12 500 $60
h . CADD Drawings Each $3 10 $ 30
Subtotal Reimbursables $ 6 , 569
TOTAL ESTIMATED BUDGET : PHASE 02 12 353 '
In compliance with Section 112 . 061 F . S .
Table 2
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 2 : Tier 2 Testing & Reporting
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. Professional Services
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 4 $740
c . Senior Project Engineer Hr $ 163 8 $ 1 , 304
d . Project Engineer Hr $ 129 0 $ 0
e . Engineer -- Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 16 $ 1 , 600
g . Staff Engineer Hr $84 0 $0
Subtotal Professional Services $3 , 644
B. Technical/Administrative Services
a . CADD Designer Hr $ 119 8 $952
b . Drafter/CADD Operator/Artist Hr $ 117 0 $ 0
c . Technical/Administrative Assistant Hr $ 81 4 $ 324
d . Technical Word Processor Hr $ 83 8 $664
e . Clerical Hr $ 50 4 $200
Subtotal Technical/Administrative Services $2 , 140
Cm Reimbursables
a . Lodging Da $ 75 0 $ 0
b . Per Diem ' Da $21 0 $0
c . Communications Fee 3 % Labor 0 . 03 $ 5 , 784 $ 174
d . CADD Computer System Hr $ 15 8 $ 120
e . Sampling & Testing Subcontractor Est $ 5 , 500 . 00 1 . 07 $5 , 885
f. Vehicle Rental & Fuel ' Da $ 150 . 00 2 $300
g . 8 "x11 " Photocopies Each $ 0 . 12 500 $60
h . CADD Drawings Each $3 10 $ 30
Subtotal Reimbursables $ 6 , 569
TOTAL ESTIMATED BUDGET : PHASE 02 12 353 '
In compliance with Section 112 . 061 F . S .
Table 3
BUDGET ESTIMATE
TITLE V PERMIT REVISION APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 3 : TITLE V RENEWAL PERMIT APLICATION
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. 'Professional Servicesa4
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 8 $ 19483
c . Senior Project Engineer Hr $ 163 64 $ 10 , 436
d . Project Engineer Hr $ 129 0 $0
e . Engineer Hr $ 112 84 $ 9 , 449
f. Senior Staff Engineer Hr $ 100 0 $0
g . Staff Engineer Hr $ 84 0 $ 0
Subtotal Professional Services $ 21 , 368
B. ';Technical/Administrative Services
a . CADD Designer Hr $ 119 24 $2 , 865
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 16 $ 1 , 329
e . Clerical Hr $ 50 0 $ 0
Subtotal Technical/Administrative Services $42195
C. Reimbursables ' ' '� '
a . Lodging Day $ 100 0 $ 0
b . Per Diem ' Day $ 21 0 $ 0
c . Communications Fee 3 % Labor 0 . 03 $ 25 , 563 $767
d . CADD Computer System Hr $ 15 24 $360
e . Vehicle Rental & Fuel " Day $ 150 0 $0
f. 8"x11 " Photocopies Each $ 0 . 12 1000 $ 120
g . CADD Drawings Each $ 3 25 $75
Subtotal Reimbursables $ 1 , 322
TOTAL ESTIMATED BUDGET ' ; PHASE b3l - : I ` =° $26 ,885
* In compliance with Section 112 . 061 F . S .
XL 11275/Budget Estimate Geosyntec Consultants
Table 3
BUDGET ESTIMATE
TITLE V PERMIT REVISION APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
PHASE 3 : TITLE V RENEWAL PERMIT APLICATION
ITEM BASIS RATE QUANTITY ESTIMATED
COST
A. 'Professional Servicesa4
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 8 $ 19483
c . Senior Project Engineer Hr $ 163 64 $ 10 , 436
d . Project Engineer Hr $ 129 0 $0
e . Engineer Hr $ 112 84 $ 9 , 449
f. Senior Staff Engineer Hr $ 100 0 $0
g . Staff Engineer Hr $ 84 0 $ 0
Subtotal Professional Services $ 21 , 368
B. ';Technical/Administrative Services
a . CADD Designer Hr $ 119 24 $2 , 865
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 16 $ 1 , 329
e . Clerical Hr $ 50 0 $ 0
Subtotal Technical/Administrative Services $42195
C. Reimbursables ' ' '� '
a . Lodging Day $ 100 0 $ 0
b . Per Diem ' Day $ 21 0 $ 0
c . Communications Fee 3 % Labor 0 . 03 $ 25 , 563 $767
d . CADD Computer System Hr $ 15 24 $360
e . Vehicle Rental & Fuel " Day $ 150 0 $0
f. 8"x11 " Photocopies Each $ 0 . 12 1000 $ 120
g . CADD Drawings Each $ 3 25 $75
Subtotal Reimbursables $ 1 , 322
TOTAL ESTIMATED BUDGET ' ; PHASE b3l - : I ` =° $26 ,885
* In compliance with Section 112 . 061 F . S .
XL 11275/Budget Estimate Geosyntec Consultants
Table 4
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
TASK 4 : RESPONSE TO REGULATORY COMMENTS
ESTIMATED
ITEM BASIS RATE JQUANTITYJ COST
A7 - Professional Servicesq,
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 4 $741
c . Senior Project Engineer Hr $ 163 8 $ 1 , 305
d . Project Engineer Hr $ 129 0 $ 0
e . Engineer Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 8 $ 801
g . Staff Engineer Hr I $ 84 0 $ 0
Subtotal Professional Services $ 29847
Be i, Technical/Administrative Services "
a . Designer Hr $ 119 0 $ 0
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 4 $332
e . Clerical Hr $ 50 0 $ 0
Subtotal Technical/Administrative Services $332
fi
C. Reimbursables
a . Vehicle Rental & Fuel " Day $ 150 0 $0
b . Communications Fee 3 % Labor $ 0 . 03 $ 3 , 179 $95
c . CADD Computer System Hr $ 15 . 00 $ 0 $0
d . 8"x11 " Photocopies Each $ 0 . 12 1 50 $6
e . CADD Drawings Each $ 3 . 00 20 $60
Subtotal Reimbursables $ 161
TOTAL ESTIMATED BUDGET : PHASE 04 6 , 3 ,341 '
" In compliance with Section 112 . 061 F . S .
X1. 11275/Budget Estimate Geosyntec Consultants
Table 4
BUDGET ESTIMATE
TION
TITLE V RENEWAL PERMIT
APPLI
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
Will ESTIMATED
TASK 4 : RESPONSE TO REGULATORY COMMENTS RATE QUANTITY COST
BAS
ITEM ,
ll
0 $0
A. Professional Services Hr . $ 196 $741
$ 185 4
a . Principal Hr 8 $ 1 , 305
b . Associate Hr $ 163 $0
$ 129 0
c . Senior Project Engineer Hr 0 $ 0
d . Project Engineer Hr $ 112 $801
$ 100 8
e . Engineer Hr $0
$ 84 0
f . Senior Staff Engineer
� I III 111Hr $2847
g . Staff Engineer Subtotal Professional Services
rw . l ;.
$0
13 , 1 chnical/Administrative
. Technical/Administrative Services Hr $ 119 0 $0
a . Designer $ 117 0
Hr 0 $0
b . Senior Drafter/Senior CADD Operator Hr $ 81
c . Administrative Assistant $ 83 4 $ 332
Hr 0 $0
d . Technical Word Processor Hr $ 50
e . Clerical $332
Subtotal Technical/Administrative Services
i°ele 77F757' f . :1110
.
777T777 7 ee') v '1
C . Reimbursable s $ 150 0 $0
Day
11 III 11 a . Vehicle Rental & Fuel ' 3% Labor $0 . 03 $3 , 179 $95
b . Communications Fee Hr $ 15 . 00 $0 $0
c . CADD Computer System Each $0 . 12 50 $6
d . 8" x11 " Photocopies Each $ 3 . 00 20 $60
e . CADD Drawings Subtotal Reimbursables $ 161
ell TOTAL ESTII lip
MATED BUDGET PHASE 04
" In compliance with Section 112 . 061 F . S .
Geosyntec Consultants
XL11275/Budget Estimate
Table 4
BUDGET ESTIMATE
TITLE V RENEWAL PERMIT APPLICATION
INDIAN RIVER COUNTY CLASS I LANDFILL
INDIAN RIVER COUNTY , FLORIDA
TASK 4 : RESPONSE TO REGULATORY COMMENTS
ESTIMATED
ITEM BASIS RATE JQUANTITYJ COST
A7 - Professional Servicesq,
a . Principal Hr $ 196 0 $0
b . Associate Hr $ 185 4 $741
c . Senior Project Engineer Hr $ 163 8 $ 1 , 305
d . Project Engineer Hr $ 129 0 $ 0
e . Engineer Hr $ 112 0 $ 0
f. Senior Staff Engineer Hr $ 100 8 $ 801
g . Staff Engineer Hr I $ 84 0 $ 0
Subtotal Professional Services $ 29847
Be i, Technical/Administrative Services "
a . Designer Hr $ 119 0 $ 0
b . Senior Drafter/Senior CADD Operator Hr $ 117 0 $0
c . Administrative Assistant Hr $ 81 0 $ 0
d . Technical Word Processor Hr $ 83 4 $332
e . Clerical Hr $ 50 0 $ 0
Subtotal Technical/Administrative Services $332
fi
C. Reimbursables
a . Vehicle Rental & Fuel " Day $ 150 0 $0
b . Communications Fee 3 % Labor $ 0 . 03 $ 3 , 179 $95
c . CADD Computer System Hr $ 15 . 00 $ 0 $0
d . 8"x11 " Photocopies Each $ 0 . 12 1 50 $6
e . CADD Drawings Each $ 3 . 00 20 $60
Subtotal Reimbursables $ 161
TOTAL ESTIMATED BUDGET : PHASE 04 6 , 3 ,341 '
" In compliance with Section 112 . 061 F . S .
X1. 11275/Budget Estimate Geosyntec Consultants