HomeMy WebLinkAbout1980-04ORDINANCE NO. 80- 4
AN ORDINANCE AMENDING INDIAN RIVER COUNTY ORDINANCE
79-6 AND THEREBY AMENDING THE INDIAN RIVER COUNTY
"ENERGY CODE"; PROVIDING AN EFFECTIVE DATE
BE IT ORDAINED BY THE BOARD OF COUNTY C01414ISSIONERS OF
INDIAN RIVER COUNTY, FLORIDA:
SECTION I
That Section 4-110 of Indian River County Ordinance 79-6 is
hereby amended to read as follows:
"Section 4-110. Energy Efficiency Code for Building Con-
struction.
(a) On March 21, 1979, Indian River County adopted as an
additional building code for said County the "Indian
River County Energy Efficiency Building Code", also
known as "The Code For Energy Conservation In New
Building Construction With Florida Amendments", and
referred to herein as the "Energy Code", three (3)
copies of which are on file in the office of the Clerk
of the Circuit Court of Indian River County, Florida,
all of which are hereby made a part of the Indian River
County Code of Ordinances as if herewith completely
incorporated herein subject only to specific additions,
deletions, and amendments as set forth in this Section
4-110. Any person, firm or corporation, violating or
convicted of a violation of any provisions of said Code
for which a penalty is or may be provided shall be in
that manner punished, otherwise, or in addition thereto,
shall be puhished as prescribed by law.
(b) Add the following sentence to the introductory paragraph
Of Section 101.3(a) at page 1-2 of the energy code:
"Only those portions of the structure which are actually
renovated shall be required to meet this energy code."
(c) Replace Section 101.3(a) 2. at page 1-2 of the energy
Code, which as amended will read:
2. Exempt Buildings:
a. Any building or portion thereof whose peak
design rate of energy usage for all purposes
is less than 1 watt (3.4 British thermal units
per hour) per square foot of floor area for all
purposes.
b. Any building which is neither heated nor cooled.
c. Any mobile home.
d. Any building or portion thereof subject to
standards established by the United States.
e. Any historical building as described in s. 267.021
(6) (Florida Statutes).
f. Any state building that must conform to the more
stringent "Florida Energy Conservation Act of
1974" and amendments thereto."
(d) Replace Section 101.3 (b) 2. at pages 1-3 and 1-4 of the
energy code which as amended will read:
"2. Exempted public buildings means:
a. Any public building or portion thereof whose peak
design rated energy usage for all purposes is
less than 1 watt (3.4 Btu's per hour) per square
foot of floor area for all purposes.
b. Any public building which is neither heated or
cooled.
c. Any mobile home.
d. Any buildings or portion thereof subject to
standards established by the United States.
e. Any state building that must conform to the more
stringent "Florida Energy Conservation in
Buildings Act of 1974" and amendments thereto."
(e) Add the following definition to Section 201.1 on page
2--4—of the energy code:
"HEATED SLAB. A floor, usually constructed of concrete,
that has heat energy supplied into the slab to provide
heating to an interior space."
(f) Add the following sentence at page 5-2 of the energy code
immediately following the last sentence of paragraph
5Ul.z(a) (1):
"Equation I -A may be used."
(g) Add the following paragraphs at page 5-2 of the energy
code following paragraph 502.2(a)3:
"502.2 (b) Insulating/Solar Glass Equivalence:
Table 5-2C in Section 502.3(c) shows shading
coefficients for solar glass which are
equivalent to insulating glass. This table
is applicable for residential buildings.
502.3 (c) Insulating/Solar Glass Equivalence:
Table 5-2C indicates the maximum shading
coefficients for single pane solar glass
which are equivalent to dual -pane insulating
glass with a U value of 0.65 or larger."
(h) Replace Table 5-1 at page 5-3 of the energy code with the
following Table andnew Footnote 1 and amended Footnote 2.
"Table 5-1
Type Al and A2 Residential Buildings
Element Mode Value
Walls
Heating
or Cooling
Uo
0.30 Max.l
Roof/Ceiling
Heating
or Cooling
Uo
0.05 Max.2
Floors Over
Heating
or Cooling
Uo
0.30 Max.
Unheated Spaces
Heated Slab
Heating
R
3.4 Min
on Grade
This code does not regulate HVAC system sizing.
HVAC systems may be sized using weather criteria
not contained in this code. This code does not
stipulate designer s::.fety factors, provisions
for future expansion, or other factors which
affect equipment sizing."
(1) Add the following paragraph 503.4(b) (4) following para-
graph 503.4(b) (3) (e) at page 5-14 of the energy code:
"503.4 (b) 4. Electric resistance comfort heating equipment
may be used separately or in conjunction with
straight air conditioning units or other HVAC
systems. The manufacturer of electric resis-
tance comfort heating equipment shall make
available to prospective purchasers, designers,
or contractors, full load energy input, over
the range of voltages at which the equipment
is intended to operate."
(m) Subparagraphs 1, 2 and 3 of Subsection 503.7(a) on page
5-18 of the energy code are hereby amended to read as
"1. Where used to control heating only, a maximum
temperature setting of 72 F.
2. Where used to control cooling only, a minimum
temperature of 79 F.
3. Where used to control both heating and cooling, it
shall have a maximum heating mode temperature
setting of 72 F and a minimum cooling mode
temperature setting of 78 F and shall be capable
of operating the system heating and cooling in
sequence. It shall be adjustable to provide a
temperature range of up to 10 F between full
heating and full cooling in sequence. It shall be
adjustable to provide a temperature range of up to
10 F between full heating and full cooling, except
as allowed in 503.3(c)4b."
(n) The introductory paragraph of Section 503.9 in the energy
code as adopted March 21, 1979, remains as follows:
"All duct work shall be constructed and erected in
accordance with Standards RS -15, RS -16, RS -18, RS -18,
RS -19, or RS -20, as applicable, which Standards super-
sede the Standards in Section 502 of the Standard
Mechanical Code now or hereafter in effect as adopted
by the County. The other provisions of Chapter V of
the said Mechanical Code apply to the extent the specific
criteria is not addressed in any applicable RS Standards.
If there is a conflict between any provisions of Chapter V
of the said Mechanical Code as amended now or hereafter
and the RS Standards, the RS Standards shall control.
Subparagraphs (a), (b), and (c) of Section 503.9 are not
amended. This amendment continues from the original
adoption of the energy code on March 21, 1979."
(o) Add thefollowing paragraph 504.2(a)2 at page 5-26 of
n�aP hatwaan "when tnsted in accordance with
"All gas and oil fired water heaters having an input rate
over 75,000 Btu/h (22KW) but less than 4,000 Btu/h per
gallon (0.3 KW/liter) of self stored water shall also
have a standby loss not exceeding
X = 2.8 + p/002 Q/V
Where Q = rated input in Btu/h V = rated volume in gallons
(S = 2.8 + 25/9 Q/V for V of 1.52 m3) or less, or 5=2.8+
41 Q/V for V exceeding 1.52 m3) when tested in accordance
with Section 2.8 of Standard RS -7. (For determining the
efficiency of oil fired units, CF = 1.0 Q = total gallons
of oil consumed and H = total heating value of the oil in
Btu/gallon)."
(p) The italicized paragraph in paragraph (e) of Section 505.2
U the energy code remains deleted. Said deleted para-
graph reads as follows:
"A single meter for the building can be installed to
determine power company charges with sub -metering for
each tenant to pro -rate the charges between tenants."
(q) Add the following after the last sentence of paragraph
602.2(a) at page 6-1 of the energy code:
"Charts 6-C and 6-D shall be used for Group R. buildings.
Thermal mass factor M - 0.8."
(r) Subparagraphs 1 and 2 of Subsection 603.3 on page 6-5 of
the energy code are hereby amended to read as follows:
"1. Where used to control heating only, a maximum
temperature setting of 72 F.
2. Where used to control cooling only, a minimum
temperature setting of 78 F."
(s) Add Chart 6-C by an inserted new page numbered 6-10.1
following page 6-10 of the energy code. Add the following
sentence under the heading of said Chart -C:
"(Includes mass factor of 0.8)"
Also add Chart 6-D to the reverse side of said new page
6-10; number said reverse side page 6-10.2 and add
the following under t e heading of said Chart 6-D:
"includes mass factor of 0.8)"
(t) Add the following sentence as a new graph following
the last paragraph of Section 802.1 following the para-
graph referring to Column F) and immediately before
Section 802.2 at page 8-2 of the energy code:
"Infiltration need not be calculated as part of the
Design -Day Method."
(u) Alternate pages 1-2A, 1-4A, 5-15A, 5-16A, 5-17A, 6-4A, and
6-5A are not adopted by the County. Appendix Tables 6-1A
at page 6-11, 6-1B at page 6-12, 6-1C at page 6-13, 6-2
and 6-3 both at page 6-14 as they existed on March 21,
1979 are deleted from the Indian River County Energy Code.
The State of Florida is now amending said Appendix
Tables. When each amended Appendix Table is adopted by
the State, each State adopted amendment shall automati-
cally become a part of the Energy Code as typical
assemblies, and which shall not be all inclusive.
Alternate Table 6-1B has been adopted by the State of
Florida and shall be inserted at page 6-12 of the
Energy Code as a typical assemblage.
(v) The Indian River County Board of Adjustments and
Appeals shall have jurisdiction over appeals from
decisions of the Building Official regarding the Indian
River County Energy Code and the standards therein.
1. For A2 buildings U. = 0.38 Max. is permitted.
2. Roof/ceiling assemblies in which the finished
interior surface is the underside of2theroof deck,
a maximum value U is 0.09 BTU/h ft. F."
(i) Add the following EQUATION 1-A on a new page of the
energy code numbered 5-6.1:
"EQUATION 1-A
UO = M x UwAw + UgAg + UdAd
A
WHERE:
UO = the average or combined thermal transmittance of the
(j) Add the following Table 5-2C after Table 5-2B at page
5-8 of the energy code:
"TABLE 5-2C
Insulating/Solar Glass Equivalence
gross exterior wall area.
A = the gross exterior wall area.
Uw = the thermal transmittance of the opaque wall.
Aw =opaque wall area
Ug = the thermal transmittance of the glazing.
= glazing area.
Equivalent Shading Coefficients
Climatological Zones
1 2 3 4 5 6 7 8 9
0.55 0.55 0.58 0.64 0.63 0.66 0.68 0.70 0.70
After calculating compliance of U values, the designer
may substitute equal amounts of solar glass with the above
shading coefficients (or lower) for insulating glass with
U values of 0.65 (or higher)."
(k) Paragraph 503.2(a) at page 5-10 of the energy code is
hereby amended as follows:
"503.2 (a) Calculation Procedures. For purposes of sizing
HVAC systems, the procedures described in
Chapters 24, 25, or 26 of Std. RS -1 may be
used, or an equivalent computation procedure.
Ag
Ud
= the thermal transmittance
of the
doors.
Ad
=door area.
M
= correction factor for mass
based
on specific heat,
density and climate."
Equivalent Shading Coefficients
Climatological Zones
1 2 3 4 5 6 7 8 9
0.55 0.55 0.58 0.64 0.63 0.66 0.68 0.70 0.70
After calculating compliance of U values, the designer
may substitute equal amounts of solar glass with the above
shading coefficients (or lower) for insulating glass with
U values of 0.65 (or higher)."
(k) Paragraph 503.2(a) at page 5-10 of the energy code is
hereby amended as follows:
"503.2 (a) Calculation Procedures. For purposes of sizing
HVAC systems, the procedures described in
Chapters 24, 25, or 26 of Std. RS -1 may be
used, or an equivalent computation procedure.
(w) Add additional Section 9 Residential Point System
and Dr. Roger Messenger and Dr. Jose Villanueva which
Addendum to the Florida Model Energy Efficiency Code for
Building Construction is incorporated into this
Ordinance with three (3) copies on file in the office
of the7fferk of the Circuit Court of Indian River County,
said Addendum numbered 901.0 - 903.5.
(x) Add an additional Section 10 Florida Power & Light
all read:
"1001 Limited solely to single family residential structures
where it is established that the Florida Power &
Light Company Optional Energy -Saving Features/Point
Awards system meets or exceed criteria established
in the energy code as amended by this Ordinance, the
Building Department shall be authorized to accept an
application that meets or exceeds 100 points over the
Florida Power & Light Company Optional Energy -Saving
Features/Point Awards in lieu of other methods of
computation as provided in the energy code. The
Florida Power & Light Company criteria designated
Optional Energy -Saving Features/Point Awards, is
hereby incorporated into this Ordinance with three
(3) copies on file in the office of the Clerk of
the Circuit Court of Indian River County, Florida.
This Ordinance shall become effective according to law.
This Ordinance shall take effect February 11, 1980.