HomeMy WebLinkAbout2022-120WORK ORDER NUMBER 4
IRC -1639
69TH STREET FROM 66TH AVENUE TO SR5/US1, RESURFACING
This Work Order Number 4 is entered into as of this 21st day June , 2022 pursuant to
that certain Continuing Contract Agreement for Continuing Geotechnical Engineering dated December 4, 2018,
renewed and amended as of December 7, 2021, collectively referred to as the "Agreement", by and between INDIAN
RIVER COUNTY, a political subdivision of the State of Florida ("COUNTY") and ANDERSEN ANDRE CONSULTING
ENGINEERS, INC. ("CONSULTANT").
The COUNTY has selected the CONSULTANT to perform the professional services set forth on Exhibit A (Scope
of Services), attached to this Work Order No. 4 and made part hereof by this reference. The professional services will
be performed by the CONSULTANT for the fee schedule set forth in Exhibit A (Fee Schedule), attached to this Work
Order and made a part hereof by this reference. The Consultant will perform the professional services within the
timeframes more particularly set forth in Exhibit A, attached to this Work Order and made a part hereof by this
reference all in accordance with the terms and provisions set forth in the Agreement. Nothing contained in any Work
Order shall conflict with the terms of the Agreement and the terms of the Agreement shall be deemed to be
incorporated in each individual Work Order as if fully set forth herein.
IN WITNESS WHEREOF, the parties hereto have executed this Work Order as of the date first written above.
CONSULTANT: BOARD OF COUNTY COMMISSIONjEA-t,�IS-...
ANDERSEN ANDRE OF INDIAN RIVER COUNTY . A......... ��rF�,•
CONSULTING ENGINEERS, INC. ;'v: ` `f '•
PBy: By: el:,',
David P. Andre• f
Peter D. O Bryan, Chair n •o,�� f►s� •o
Title: Principal •.��,; Tib'
BCC Approved Date: .Tune 21 2022
Attest: Jeffrey R. Smith, Clerk of Court and
Comptroller _
By:
Approved:
Approved as to form and legal sufficiency:
Deputy Clerk
Jason A. Br/own, County Administrator
William K. DeBraal, Deputy County
Attorney
EXHIBIT A
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
Geotechnical Engineering
Construction Materials Testing
Environmental Consulting
Indian River County Engineering Department
1801 27t` Street, Building `A'
Vero Beach, Florida 32960
Attention: Mr. Mark Winslow, P.E., CFM
Project Engineer
AACE Proposal No. P22-2311
May 20, 2022
Revised May 31, 2022
Subject: PROPOSAL FOR CONSTRUCTION MATERIALS TESTING
69— STREET (66"; AVENUE TO SR5/US-1) FULL DEPTH RECLAMATION PROJECT
FM No. 438073-1-54-01
IRC PRoiEcr No. 1639
INDIAN RIVER COUNTY, FLORIDA
Dear Mr. Winslow:
Andersen Andre Consulting Engineers, Inc. (RACE) is pleased to present this proposal for construction materials testing
services during improvements to portions of 69h Street, as indicated above. The purpose of our services, as discussed
further herein, will be to provide materials testing in general accordance with the project plans and technical specifications.
BACKGROUND INFORMATION
We understand that the proposed improvements to 69h Street consist of refurbishing (through the Full Depth Reclamation
(FDR) process) the roadway for the following three segments (approximately 1.6 miles): from STA 118+13.62 to STA
150+28.55, STA 168+50.39 to STA 217+07.44 and STA 234+20.64 to STA238+69.85. Testing associated with the
relocation of a 12" PVC water main has been presented in a separate proposal (RACE P22-2319 dated May 26, 2022).
Further, we understand that this is an FDOT Small County Outreach Program (SCOP). Therefore, based on our
understanding of the project and on our conversations with the FDOT State Materials Office, the quality control measures
listed in the FDOT's Developmental Specification T332 Full Depth Reclamation, including "Addendum 3" provided to us
by the County, should be adhered to.
- Balance ofpage intentionally left blank -
834 SW Swan Avenue, Port St. Lucie, Florida 34983 Ph: 772-807-9191 Fx: 772-807-9192 www.aaceinc.com
69TH STREET Page -2-
FM No. 438073-1-54-01
IRC PRojEcr No. 1639
AACE Proposal No. P22-2311
SCOPE OF SERVICES
Based on the FDOT's Developmental Specification T332 and on our experience with similar projects (including 58 h
Avenue), we understand that required QC services will include the elements listed below:
Field and Laboratory Testiniz of FDR Roadway Base and Shoulders:
- Obtaining samples of pulverized road base for laboratory gradation testing at a frequency of one sample for
every 2,000LF per lane, or as needed.
- Obtain samples of the FDR mix for laboratory Marshall Stability testing every 2,000LF per lane, or as needed.
- Obtaining one sample for laboratory moisture/density relationship testing at a frequency of one sample for
every 2,000LF per lane, or as needed.
- Performing one in-place field density test for every 50OLF of the compacted mixture on days selected by IRC
staff (or as otherwise requested by IRC staff).
- Obtaining composite samples of the Refurbished Stabilized Shoulders and widened areas at a frequency of one
sample for every 2,000 LF for laboratory Limerock Bearing Value (LBR) testing, or as needed.
- Obtaining composite samples of the FDR mix at a frequency of one sample for every 2,000 LF for laboratory
Limerock Bearing Value (LBR) testing, or as needed.
- Performing in-place density testing of shoulder stabilized subgrade (approximately one (1) test per every 2
LOTS of shoulder (about 1,000 LF), each direction or at the direction of the County.
- Performing in-place density testing of embankment, as needed.
QC services during paving operations:
- Performing asphalt plant inspection services during three (3) paving operations (selected by IRC).
- Obtaining roadway cores on four (4) occasions after paving operations for specific gravity (density)
determination (estimated three (3) cores obtained during each event).
- Obtaining a maximum of four (4) bulk samples of asphalt for asphalt content and gradation testing.
Drainage Construction:
- Performing in-place density testing of soil used to backfill all drainage excavations
Miscellaneous Testine
- Performing concrete testing services for non-structural concrete (sidewalks and ADA ramps, curbing, headwall,
bus shelter pad, and driveways).
- Perform density testing for general restoration and corrective construction (driveway restoration, sidewalk
subgrade, utility and hydrant relocations, etc.)
We note that no field and/or laboratory testing of the FDR mix is included herein for the purpose of confirmin¢ that a
Structural Number of 1.8 has been achieved. We understand that such testing will be the responsibility of the Contractor's
testing consultant.
Based upon our understanding of the project plans and our prior experience with projects similar to this one, we estimate
the cost of the services will be approximately $46,510.00. The actual cost of AACE's testing services will be a function of
work actually performed in accordance with the attached unit fee schedule (in accordance with the continuing service
contract between Indian River County and RACE, Contract #20211207). Contractor efficiency, methodology and changes
in testing frequencies may affect the testing cost. We will notify you in advance if it appears that the cost estimate will be
exceeded.
- Balance ofpage intenhonalyleft blank -
69TH S'T'REET
FM No. 438073-1-54-01
IRC PRoJECT No. 1639
RACE Proposal No. P22-2311
Page -3-
To authorize us to proceed with this project, please execute and return to us a copy of the attached Project Agreement form
or a Purchase Order number. If you have any questions or if we can provide any additional information, please feel free
to contact us at your convenience.
Best Regards,
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
David P. Andre, P.E. Peter G. Andersen, P.E.
Principal Engineer Principal Engineer
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
WWW.AACEINC.COM
69TH STREET
FM No. 438073-1-54-01
IRC PRojEcr No. 1639
AACE Proposal No. P22-2311
ITEM #1: Field and Lab Testing of FDR Roadwav Base and Shoulders and Roadwav Wideni
Page -4-
• Road Base Particle Size Analysis of Pulverized Base:
- Washed Sieve Analyses; 14 tests @ $95.00/test..................................................
$1,330.00
- Sample Preparation; 14 tests @ $35.00/test.......................................................
$490.00
• Marshall Stability of FDR Mixture: 14 tests @ $190.00/test..........................................
$2,660.00
• Moisture/Density Relationship (Proctor) Testing: 14 tests @ $91.00/test ...............................
$1,274.00
• LBR Testing; 15 tests @ $315.00/ test ............................................................
$4,725.00
• In -Place Density Testing of FDR Mix, Widening Base & Stabilized Shoulders;
- 80 tests @ $25.00/test (minimum 4 tests per hour, per trip) .........................................
$2,000.00
• In -Place Density Testing of Roadway Embankment (as needed);
- 25 tests @ $25.00/test (minimum 4 tests per hour, per trip) ...........................................
$625.00
• Engineering Technician (man-hours for sample collection, limited standby, etc.)
- 65 hours @ $63.00/hour.....................................................................
$4,095.00
Item #1 Subtotal: ........................................... $17,199.00
ITEM #2: QC Services During Paving Operations
• Asphalt Plant Inspection - Senior Transportation/Roadway Technician;
- 3 Days x 10 hours/day @ $85.00/hr. x 1.5 (nighttime testing rate) ................................... $3,825.00
- Asphalt Content and Extraction/Gradation Testing; 3 samples x $210.00/sample ........................ $630.00
• Roadway Coring (3 Coring Events)
- Engineering Technician (for Roadway Coring - 2 techs. required for all coring);
4 events @ 8 hours/event x @ $63.00/hour x 2 technicians ........................................ $4,032.00
- Coring Mobilization; 4 events x $100.00/mob..................................................... $400.00
- Core Machine Usage;4 days $150.00/day .......................................................$600.00
- Generator Usage; 4 days x $50.00/day............................................................ $200.00
- Specific Gravity Testing (Unit Weight) of Cores; 12 cores x $37.00/core................................ $444.00
Item #2 Subtotal: ........................................... $10,131.00
► ITEM #3: Drainage Construction
• Proctor Testing- .5tests @ $91.00/test............................................................. $455.00
• In -Place Density Testing of Excavation Backfill;
- 225 tests @ $25.00/test (minimum 4 tests per hour, per trip) ........................................ $5,625.00
• Engineering Technician (man-hour estimate for road closure standby, etc)
-30 hours @ $63.00/hour.....................................................................1 8$ , 90.00
Item #3 Subtotal: ............................................ $7,970.00
► ITEM #4: Miscellaneous Testi
• Sidewalk, Curbing, ADA Ramp Subgrade: 30 density tests @ $25.00/test................................. $750.00
• Compressive Strength Testing of Concrete (sidewalk, headwall, ramps, etc.);
- 8 sets of 4 specimens @ $95.00/set.............................................................. $760.00
• Modified Proctor Testing; 3 tests @ $91.00/test..................................................... $273.00
Item #4 Subtotal: ............................................ $19783.00
► ITEM #5: Professional/Administrative Services Estimate:
• Snr. Project Engineer:
- Limited Meeting Attendance - 3 meetings x 3 hrs./mtg. x $128.00/hour .............................. $1,152.00
- Project Coordination, review of testing results; 25 weeks x 2 hrs./week x $128.00/hour ................. $6,400.00
• Technical Secretary; 25 weeks x 1.5 hrs./week x $50.00/hour........................................ $1,875.00
Item #5 Subtotal: ............................................ $9,427.00
PROTECT TOTAL: $46,510.00
69TH STREET
FM No. 438073-1-54-01
IRC PRojEcr No. 1639
RACE Proposal No. P22-2311
TERMS AND CONDITIONS
Page -5-
(1) Unit rates apply to standard working days, Monday through Friday, 7:00 a.m to 6:00 p.m. Testing and hourly rates
will be increased by 50% for weekend, holiday or after-hours services (i.e., services performed before 7:00 am or
after 7:00 pm). Our man-hour rates as presented herein are based on day -time testing only. No allowances for
nighttime work are reflected in our fee.
(2) The contractor (or County personnel) should contact Andersen Andre Consulting Engineers, Inc. at (772) 807-9191
a minimum of 24 hours prior to any testing and 48 hours prior to weekend and evening work.
(3) If our testing estimate for a specific work element is insufficient for that particular activity, resources from another
work element can be used without prior authorization from the client as long as our total cost estimate is not
exceeded. We will notify you in advance if it appears that the cost estimate presented in the attached unit fee
schedule will be exceeded.
(4) AACE has not been provided with the selected Contractor's proposed schedule (i.e.; paving days, FDR days, etc.).
Therefore, man-hours and associated testing quantities are based on our experience with similar projects. It is
possible that our testing budget may require revision based on contractor efficiency, methodology and scheduling.
(5) Soil sample and concrete cylinder pickup for laboratory testing (e.g., Proctor, LBR testing, compressive strength,
etc.) will be billed at;63.00/hour if not scheduled with other work.
(6) Our services do not include reviewing, monitoring or reporting any aspect of the required Maintenance of Traffic
(M.O.T.) that may be required for this project.
(7) AACE's field technicians and engineers do not direct or witness the performance of any work. Neither the presence
of an AACE representative on-site nor the observation and testing performed by our firm implies AACE's
responsibility for defects discovered in the construction work.
(8) AACE will not be responsible for job or site safety for this project; job site safety will be the sole responsibility of
the contractor.
(9) AACE will not have stop -work authority. Should our representatives encounter materials or workmanship that,
either based on direct testing or on our experience with similar projects, does not appear to meet the engineering
plans and specifications, we will notify Indian River County immediately. Results will not be relayed to the
Contractor without prior consent of the County.
(10) We understand that no FDOT Earthwork/Density Log Book will be required for this project.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
WWW.AACEINC.COM
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
PROFESSIONAL SERVICES AGREEMENT
AACE Proposal No: P22-2311
Project Name: 69th Street (66th Avenue to SR5/US-1) Full Depth Reclamation Project
FM No. 438073-1-54-01 / IRC Project No. 1639
Client: Indian River County Address: 1801 27th Street, Building `A'
Attention: Mr. Mark Winslow, P.E., CFM, Project Engineer Vero Beach, Florida 32960
Client hereby requests and authorizes Andersen Andre Consulting Engineers, Inc. ("AACE") to perform the following
services:
Provide materials testing services during the 69' Street Improvement Project, as described herein.
Estimated Budget:
$46,510.00
Payment Terms:
Net 30 days from invoice date; invoices will be sent every four weeks for continued or extended projects. Interest charges, 11/2%
per month following the due date.
Proposal Acceptance:
By accepting this Proposal, the Terms and Conditions of this Proposal, including the Terms on this page, and Andersen Andre
Consulting Engineers, Inc.'s General Conditions appearing on the reverse side of this page are incorporated herein by reference.
In the event this Professional Services Agreement was received by facsimile or via email, Client hereby confirms that the above
described Proposal, the Terms and Conditions of this Proposal, including the Terms on this page, and Andersen Andre
Consulting Engineers, Inc.'s General Conditions have been made available and are incorporated in this agreement.
PURSUANT TO FLORIDA STATUTES SECTION 558.0035 (2013) AN INDIVIDUAL EMPLOYEE OR
AGENT MAY NOT BE HELD INDIVIDUALLY LIABLE FOR NEGLIGENCE.
Accepted by CLIENT:
By:
Name:
Title:
Date:
Billing Address:
Phone No.
Accepted for AACE:
By.
Name: David P. Andre, P.E.
Title:Principal Principal Engineer
eer
Date: May 31, 2022