Laserfiche WebLink
Indian River County Administration Complex <br /> Bldg. 1 - 2vd Floor East End Punchlist - Friday 04/06/07 <br /> April 16, 2007 <br /> Page 8 <br /> Office 224 (continued) <br /> 4. North wall, water stains, some type of liquid stain on the drywall needs to be repainted . Also, to the bottom <br /> of the electrical outlet in this same location there is an irregularity in the drywall . Needs to be sanded and <br /> repainted. <br /> 5 . Bottom left jamb of the window opening needs to be sanded and repainted. Outside edge is very irregular. <br /> 6. In front of Door 224 approximately 6 to 7 feet, dark area in the carpet. Not sure if this is part of the carpet or <br /> something got on the carpet. Where carpet was installed, carpet tiles were installed incorrectly. <br /> Oven Office Area 225 <br /> 1 . North wall the wall adjacent to Office 224 to the bottom left of the electrical outlet is irregularity in the <br /> drywall needs to be patched and repaired. <br /> 2. Drywall around electrical outlet needs to be sanded and repainted. <br /> 3. East wall, drywall below Data Outlet 29D & 30D needs to be patched and repaired, nick in the drywall. Also, <br /> drywall around the Quad Outlet in this same location needs to be sanded and repainted. <br /> 4. Quad Outlets to the right and left of Data Outlet 35D, 36D, 37D & 38D needs to be cleaned of paint. <br /> 5. South wall the wall adjacent to Office 203 irregularities in the drywall about center portion and also and <br /> carpet adhesive on the drywall . <br /> 6. West wall at the Computer Room 226, hollow metal paint on the drywall needs to be removed and drywall <br /> needs to be repainted . <br /> 7. Top right and left of the hollow metal widow frame, the window head complete length drywall needs to be <br /> sanded and repainted. <br /> 8. West wall opposite Office 224, fingerprints and carpet glue on the wall, needs to be repainted. <br /> 9. About a dozen ceiling tiles are missing in Room 225A Open Office area. . <br /> 10. Ceiling to the top right corner of Office 224, approximately 2°d full file off that outside comer is chipped. <br /> 11 . Ceiling grid between Office Area 224 and Supply Grille along central file room wall, grid is dirty. <br /> 12 . Ceiling tile off the exterior window, the 2°d window from Office 224, 4ih tile off the wall is chipped. <br /> Computer Room 226 <br /> 1 . Computer Room 226 is not complete and will punched out at later date. <br /> Production Room 227 <br /> 1 . Door 227A inside face has been sanded, needs to be finished completely. Also, bottom middle of the door has <br /> a scratch in it. <br /> 2 . Hollow metal door frame needs to be touched up with paint on the bottom right and left approximately 16" up <br /> from the floor. <br /> 3 . Drywall to the left of Door 227A needs to be sanded and repainted just above the bottom hinge, irregular. <br /> Also, in this same area there appears to be a bulge in the drywall. <br /> 4. Bottom left where Data Outlet 13D & 14D, marks on the drywall need to be cleaned and painted. <br /> 5 . Top right of Data Outlet I ID & 12D mark on the drywall needs to be cleaned. <br /> 6. Southwest inside comer needs to be sanded to receive vinyl base. <br /> 7. South wall above the Easternmost duplex outlet, drywall needs to be sanded and repainted and also, marks on <br /> the drywall needs to be cleaned and repainted. <br /> 8. Door 228A inside face at door frame of Production 227 , left side, the bottom left is damaged, dented, and also <br /> door frame needs to be touched-up with paint on the bottom right and left sides. <br /> 9. Ceiling grid to the top left of Door 228A and Room 227 is damaged. Finish is chipped. That is also true of <br /> the ceiling grid adjacent to Supply Air Grille and 1 ceiling tile off the heat detector and sprinkler head. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />