My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-263
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-263
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2016 12:53:18 PM
Creation date
9/30/2015 11:02:22 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
08/20/2007
Control Number
2007-263
Agenda Item Number
County Administrator Signature
Entity Name
Turner Construction
Subject
Certificate of Substantial Completion
Area
New County Administration Bldg.
Supplemental fields
SmeadsoftID
6488
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Administration Complex <br /> Bldg. 1 - 1st Floor - West - Punch List - Tuesday - July 24, 2007 <br /> August 02, 2007 <br /> Page 30 <br /> Men's Restroom 507 (continued) <br /> 10. Tape on the 2x4 light fixture above Door 507 needs to be removed . <br /> 11 . Grout around the water closet where it meets the ceramic tile floor needs to be cleaned neat and also voids in <br /> the grout needs to be patched and repaired. <br /> Women's Restroom 508 <br /> 1 . Outside Door 508 finish needs to be cleaned of paint. <br /> 2. 2x2 light fixture just above Door 508 not working. <br /> 3. Ceramic tile base and floor need to be cleaned. <br /> 4. Escutcheon plate at lavatory drain line needs to be pulled tight to the ceramic tile. <br /> 5 . Grout around the water closet where it meets the ceramic tile floor needs to be cleaned neat and also voids in <br /> the grout needs to be patched and repaired. <br /> 6. Top left 2x6 black trim where it abuts the drywall finish void needs to be filled in. <br /> 7. Ceiling tile along the wall just above the water closet grab bar grid is damaged, not acceptable this needs to be <br /> redone and also, to set flush and level to the wall. <br /> S. Paper towel dispenser is not properly secured to the wall. <br /> 9. Floor drain cover needs to be cleaned of dirt, debris and grout. <br /> 10. Painters tape has been left on top of the ceramic tile base of the drywall finish put over it, tape needs to be <br /> removed and finish patched and repaired as necessary . <br /> Fire sprinkler Riser Room 509 <br /> 1 . Door 509 needs to be cleaned of paint, drywall mud. Edges arte scratched and damaged inside and out. <br /> 2 . All penetrations in the walls need to be filled in. <br /> 3 . Hollow metal frame where it meets the concrete floor needs to be caulked. <br /> 4. <br /> GENERAL NOTES : <br /> 1 . All metal transition strips from carpet to tile needs to be grouted in between the tile and the metal transition <br /> strip throughout the whole building where this occurs. <br /> 2. All carpet where it is cut into the hollow metal doorjamb needs to he re-looked at. Concern that debris has <br /> not been cleaned up off the floor. Carpet that is laying flush to the floor is very rough and irregular, not cut <br /> neat to the hollow metal door frame. <br /> 3. All wood doors in numerous areas have paint in the grain, needs to be cleaned off. <br /> 4. All windows sills on the underside should be cleaned of paint and caulked where the window sill abuts the <br /> drywall . <br /> 5 . All light switch covers, electrical outlet devices need to be cleaned of paint, drywall mud, etc. <br /> 6. All inside and outside corners of vinyl base, the profile base need to be cut tight and no open joints and <br /> secured to the wall. <br /> 7 . All cabinetry needs to be adjusted so the door and drawers set level and plumb and operate properly. <br /> 8 . All vinyl base needs to be cleaned of drywall dust, scratches, dirt, debris, etc. <br /> 9 . All doors, drawers and cabinets need to be adjusted to set level and plumb and latch properly. <br /> 10. All closures need to be adjusted to provide 51b closing force for ADA. <br /> 11 . All paint needs to be removed from glass especially where the glass and the glass grazing meet at the window <br /> stops. <br /> 12. All TE units in the ceiling need to be cleaned of fingerprints in the ceiling mounted units . <br /> 13 . All locations of hollow metal frames that are adjacent to VCT flooring need to be caulked. <br /> 14. All exterior windows the right and left inside comers where the window sill and drywall jambs meet need to <br /> be cleaned of drywall dust. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />