Laserfiche WebLink
Indian River County Administration Complex <br /> Bldg. 1 - 1st Floor - West - Punch List - Tuesday - July 24, 2007 <br /> August 02, 2007 <br /> Page 5 <br /> Pick-up Area 404 (continued) <br /> 13. Duplex electrical outlets on the east wall in front of Door 405 drywall around it needs to be sanded and <br /> repainted. Finish is rough and irregular. <br /> 14. West wall of Pick-up outside corner at Office 444 needs to be touch-up with paint, corner bead damaged, area <br /> has been touched-up. Also, dent needs to be removed around the electrical outlet fixture cover. <br /> Customer Service Area 405 <br /> 1 . West wall adjacent to area leading to Door 405 wall is damaged about 30 inches off the floor in numerous <br /> areas need to be patched and repaired. Also, in this same location at the ceiling grid holes in the drywall need <br /> to be patched and repaired. <br /> 2. Bottom edge of dropped soffit between the 1 '` and 2nd light fixtures coming off the west wall needs to be <br /> sanded and repainted, irregular. That is also true of the bottom edge between the 4`h and 5i° recessed can <br /> lights. <br /> 3 . Bottom edge of dropped soffit coming off the coral cast column between the 1 '` light fixture and the 2nd light <br /> fixture outside edge needs to be sanded and redone. <br /> 4. Bottom right of borrowed light 444 BU needs to be sanded and repainted, rough and irregular. Also bottom <br /> left of the borrowed light 444 BLl irregularity in the drywall finish needs to be sanded and repainted. <br /> 5 . Ceiling tile coming off the left corner of Office 444, 1 ' full ceiling tile, chipped, fingerprints in the tile. <br /> 6. Outside comer vinyl base not secured to the wall at Office 444 . <br /> 7. Bottom left of hollow metal frame 444, imperfection in drywall needs to be patched, sanded and repainted. <br /> 8 . Two ceiling tiles coming off the Reception counter header, that is two off of the left or west wall and one and <br /> two off the south face of the header. <br /> 9 . Ceiling tile damaged , 3`d ceiling tile off the west wall and 3`d ceiling tile off the drywall header over the <br /> Reception counter, tile damaged. <br /> 10. Ceiling grid, 3rd grid coming off the drywall header lining up on the 1 " recessed can light to the right of the <br /> coral cast column . <br /> Staging Area 406 <br /> 1 . Right outside comer of Office 444 north face of drywall above the vinyl base needs to be patched and <br /> repaired, corner is dented and damaged, needs to be patched and repaired. <br /> 2. West wall of Office 444 patched areas need to be sanded and repainted Also, to the top right of data outlet <br /> Dl l & D12 chip in the finish needs to be patched and repaired . <br /> 3 . South wall center of the wall above the vinyl base needs to be sanded and repainted where it has been <br /> patched. <br /> 4. Drywall to the top left of the westernmost electrical outlet needs to be sanded and repainted. <br /> 5 . Right inside corner of the west wall at Staging Area 406 needs to be sanded and repainted, finish is rough and <br /> irregular approximately 30 inches up off the floor. Also, outside comer of the 1 ft. projection of the wall <br /> heading east is rough and irregular, uneven at the comers . <br /> 6. Door 405B no view light or metal frame installed. <br /> 7. Door 405B bottom right corner of face needs to be cleaned. <br /> 8. Left of hollow metal frame 405B paint needs to be cleaned off the top of the vinyl base left and right hand <br /> sides, inside corner of the vinyl base joint is excessive. <br /> 9. Ceiling tile missing to the right of the exit sign above Door 405B. <br /> 10. Double ceiling grid along the south wall along Stairs 003, not acceptable, not parallel to each other. <br /> 11 . Dropped header above the wall that has Door 405B in it, right bottom edge needs to be sanded and repainted. <br /> 12. Right comer, on the east side of the dropped soffit and above the westernmost Reception counter, the east end <br /> of Staging Area 406, face of drywall is very rough and irregular, especially at the bottom edge and the corner, <br /> needs to be sanded and repainted. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />