Laserfiche WebLink
BAIndian River County Turner <br /> Administration Complex <br /> Final GMP Summary <br /> Qualifications & Assumptions <br /> Report Date: August 16, 2005 <br /> Bid Package 16 Electrical <br /> Specifications : <br /> 1 16011 - 3 . 4 - E3 : Excavations shall be made to accommodate planed progress , and as <br /> required to maximize the efficiency of installation between point A and point B without <br /> restrictions, within OSHA guidelines . <br /> 2 16011 - 3 . 4 - F4 : Concrete encasement for communications ductbanks included only <br /> when crossing beneath a roadway . <br /> 3 16011 - 3 . 11 Identification for Division 16 and 17 shall be provided per NEC in lieu of the <br /> requirements of this specification section . <br /> 4 16102 - 2 . 1 and 2 . 2 : The GMP is based on Leviton as an acceptable manufacturer of <br /> devices . <br /> 5 16110 - 2 . 3 : All major manufacturers of EMT couplings and connectors as well as non - <br /> insulated throat EMT connectors may be utilized . <br /> 6 16120 : MC cable shall be utilized where allowed by the NEC . <br /> 7 16120 - 2 . 1 - H : Standard type wire / wing nuts shall be utilized for all copper conductor <br /> connections # 8 AWG and smaller . <br /> 8 16425 - 1 . 7 - A : All major manufacturers shall be included as acceptable . <br /> 9 16450 - 2 . 3 : Grounding connections to building steel may be exothermic type in lieu of <br /> bolted . <br /> 10 16471 - 2 . 11 - A : All major manufacturers shall be included as acceptable . <br /> 11 16490 - 1 . 3 - B - 1 : All major manufacturers shall be included as acceptable . <br /> 12 16501 : Light fixtures shall be supported per the National Electric Code ( NEC ) . <br /> 13 The Decorative " L7 fixtures indicated in the Interior Finish Specifications and shown on <br /> the Reflective Ceiling Plans are to be furnished by Song & Associates . The GMP includes <br /> installation of these fixtures . <br /> 14 16610 : Lightning protection system is included in the GMP . <br /> 15 The Sound System , Multimedia System and TV Lighting System in the Commission <br /> Chambers are included in the GMP as an allowance . <br /> Drawings : <br /> 1 Security and CATV raceways are included as an outlet box , plaster ring and 1 " conduit <br /> stubbed above the ceiling . <br /> 2 0 - E0 . 0 : Paging / Background Music , Intercom , Master Clock , MATV / CATV systems are <br /> not included . <br /> 3 0 - E1 . 1 : Empty raceways with pull string only for the cameras indicated ( poles cabling , <br /> terminations , equipment is included in the security system allowance ) . <br /> Page 19 �. <br />